About This Manual
This manual is applicable to face recognition terminal. The Manual includes instructions for using and managing the product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version in the company website. Please use this user manual under the guidance of professionals. Legal Disclaimer REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS. OUR COMPANY SHALL NOT TAKE ANY RESPONSIBILITES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, OUR COMPANY WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW. OUR COMPANY SHALL NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
Regulatory Information
FCC Information
Please take attention that changes or modification not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help..
The device must not be co-located or operating in conjunction with any other
antenna or transmitter. This equipment should be installed and operated with a
minimum distance 20cm between the radiator and your body.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
EU Conformity Statement
This product and – if applicable – the supplied accessories too are marked with “CE” and comply therefore with the applicable harmonized European standards listed under the RE Directive 2014/53/EU, the EMC Directive. 2014/30/EU, the LVD Directive 2014/35/EU, the RoHS Directive 2011/65/EU. 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see. www.recyclethis.info 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include.
lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper
recycling, return the battery to your supplier or to a designated collection
point. For more information see:
www.recyclethis.info.
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (A)/NMB-3(A) standards requirements. Use only
power supplies listed in the user instructions:
Model | Manufacturer | Standard |
---|
TS-A018-120015Ec
| Shenzhen Transin Technologies Co., Ltd| CEE
Safety Instruction
These instructions are intended to ensure that user can use the product
correctly to avoid danger or property loss. The precaution measure is divided
into Warnings and Cautions: Warnings: Neglecting any of the warnings may cause
serious injury or death.
Cautions: Neglecting any of the cautions may cause injury or equipment
damage.
|
---|---
Warnings Follow these safeguards to prevent serious injury or death.|
Cautions Follow these precautions to prevent potential injury
or material damage.
Warnings
- All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and other related regulations in your local region.
- Please use the power adapter, which is provided by normal company. The power consumption cannot be less than the required value.
- Do not connect several devices to one power adapter as adapter overload may cause over-heat or fire hazard.
- Please make sure that the power has been disconnected before you wire, install or dismantle the device.
- When the product is installed on wall or ceiling, the device shall be firmly fixed.
- If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service center.
- If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the device yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.)
Cautions
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).
- Do not place the device in extremely hot (refer to the specification of the device for the detailed operating temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation. The appropriate temperature is -20℃ to 65℃.
- The device cover for indoor use shall be kept from rain and moisture.
- Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire danger).
- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and affecting the endurance of sensor at the same time.
- Please use the provided glove when open up the device cover, avoid direct contact with the device cover, because the acidic sweat of the fingers may erode the surface coating of the device cover.
- Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do not use alkaline detergents.
- Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs.
- Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer.
Preventive and Cautionary Tips
To guarantee the card reader works properly, please read and obey the notes
below.
- If the card reader is powered by the controller, the power supply distance is recommended to be no longer than 100m. If the distance is longer than 100m, you are advised to power the card reader by external 12V (range: -%10 ~ +%10) DC
- To guarantee the communication between the controller and the card reader, you must use RVVP cable above 0.5 to connect them.
- If the card reader is installed outside or in environment easy to permeable, it is advisable to install a waterproof shield.
- If you need to install several card readers, the distance among them must over 30cm.
- To reduce the noise in long distance transmission, the shield of cable should connect to the GND of both controller and card reader terminal.
- Please take care of your card and report card loss in time when card is lost.
- If you require a higher security level, use multiple authentication modes.
- Multiple card types are supported. Please select an appropriate card type according to the card performance and the usage scenarios.
Preventive and Cautionary Tips
To guarantee the card reader works properly, please read and obey the notes below.
- If the card reader is powered by the controller, the power supply distance is recommended to be no longer than 100m. If the distance is longer than 100m, you are advised to power the card reader by external 12V (range: -%10 ~ +%10) DC power supply, which is nonswitched and linear.
- To guarantee communication between the controller and the card reader, you must use RVVP cable above 0.5 to connect them.
- If the card reader is installed outside or in an environment easy to permeable, it is advisable to install a waterproof shield.
- If you need to install several card readers, the distance among them must over 30cm.
- To reduce the noise in long-distance transmission, the shield of cable should connect to the GND of both controller and card reader terminal.
Over View
The card reader is a kind of high-performance product, with a 32 bit high- speed processor. It communicates with access controller via either RS-485 protocol (AES encrypted) or Wiegand protocol. And a build-in tamper-proof module helps to protect card reader from malicious damage. As to the physical appearance, the PC+ABS material makes water proof and dust proof possible in poor environment.
Indicator and Component
Introduction for DIP Switch
The DIP switch module is shown below. The No. of DIP switch from left to right is 1 ~ 8.
Description of DIP Switch
No. | Description | DIP Switch Status |
---|---|---|
1 ~ 4 | Address of RS-485 | 1: 1 |
0: 0
5
| Card Security
Note: Only available when
Wiegand is enabled.
| 0: Disable M1 card encryption function,
disable non-M1 card
No. | Description | DIP Switch Status |
---|---|---|
Recognition function, enable door open via NFC card. |
1: Enable M1 card encryption function, enable non-M1 card Recognition function, disable door open via NFC
card.
6| Wiegand protocol or RS-485
protocol.
| 0: Wiegand protocol;
1: RS-485 protocol.
7
|
Wiegand Protocol (available when No. 6 is 0)
| 1: Wiegand protocol of 26-bit;
0: Wiegand protocol
of 34-bit.
8| Matched Resistance
(available for RS-485 protocol)
| 1: Enable;
0: Disable.
Definition of Cable
The description of 10 cables is shown below.
Description of Cable
Color | Description |
---|---|
Orange | Red LED Control (available for Wiegand Protocol) |
White | Wiegand W1 (available for Wiegand Protocol) |
Green | Wiegand W0 (available for Wiegand Protocol) |
Color | Description |
--- | --- |
Blue | RS-485- |
Yellow | RS-485+ |
Red | PWR (+12 VDC) |
Black | GND |
Gray | TAMPER (available for Wiegand Protocol) |
Purple | Beep Control (available for Wiegand Protocol) |
Brown | Green LED Control (available for Wiegand |
Protocol)
Wiring Cables
Purpose:
Wire the cables between controller and card reader, thus establishing the
communication between them.
Steps for RS-485 communication mode:
- Set the DIP switch of No. 6 as 1.
- Set the DIP switch of No. 1 ~ 4 for RS-485 address. For details, please refer to 3.1 Introduction for DIP Switch.
- Wire the cable between controller and card reader as shown below.
Wiring for RS-485 Communication Mode Steps for Wiegand communication mode
- Set the DIP switch of No. 6 as 0.
- Set the DIP switch of No. 5 and 7 for reading card mode and Wiegand protocol. For details, please refer to 3.1 Introduction for DIP Switch.
Wiring the cable between controller and card reader as shown below.
Installing Card Reader
Before you start:
Set the DIP switch. For details, refer to 3.1 Introduction for DIP Switch.
Installation for LTK1101/ 02/ 03/ 04 series card reader Steps.
- Fix the plate on the wall or other places by using two screws (PA4×25-SUS). Make sure the arrows on the plate are upwards.
- Check whether the plate is fixed and in the right direction.
- Slide the card reader from direction A to B along the plate side until the bottom matches the joint. Make sure the card reader is tightly on the wall or other places.
- Drag and move the card reader to make sure it is fixed.
Sound Prompt and Indicator
After the card reader is powered on, LED status indicator will turn green and
flashing for 1 time. Then it will turn red and flashing for 3 times. At last
the buzzer will send out a beep sound indicating the starting up process is
completed. When using the card reader, it will send out different sounds
prompt and the LED indicator to indicate different statuses. You can refer to
tables below for detailed information.
Description of Prompt Sound
Sound Prompt | Description |
---|
One beep
| Swiping card prompt
Pressing keys prompt
Prompt for too long card No. input by
pressing keys.
Time out prompt for pressing keys or
swiping card.
For Card + Password authentication: prompt for entering password after swiping
the card.
Two rapid beeps| The operation of pressing keys or swiping
card is valid.
Three slow beeps| The operation of pressing keys or swiping
card is invalid.
Rapidly continuous beeps| Prompt for tamper-proof alarm.
Prompt for buzzer alarm.
Slowly continuous
beeps
| The card reader is unencrypted.
LED Indicator Status| Description
---|---
Green (flashing for 1 time), and red
(flashing for 3 times)
|
The card reader is power on.
Flashing green
| For Card + Fingerprint authentication: prompt for pressing the fingerprint after
swiping the card.
The operation
fingerprint.
| of| configuring| the
Solid green for 2s| The operation of pressing keys or swiping
card is valid.
Solid red| Card reader is working normally.
Flashing red for 3
times
| The operation of pressing keys or swiping
card is invalid.
Flashing red| For RS-485 protocol: Registering failed or
card reader is offline.