Orange Electronic OGL03 O-Genius Lite TPMS Diagnostic Tool User Manual

June 6, 2024
Orange Electronic

Orange Electronic OGL03 O-Genius Lite TPMS Diagnostic Tool

Orange-Electronic-Lite-TPMS-Diagnostic-Tool

Federal Communication Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. . Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
(Example – use only shielded interface cables when connecting to computer or peripheral devices).

FCC Radiation Exposure Statement

This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 0.5 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The antennas used for this transmitter must be installed to provide a separation distance of at least 0.5 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Product and Accessories

Orange-Electronic-Lite-TPMS-Diagnostic-
Tool-2

Specifications

  • Battery Operating Voltage: DC 6V~9.5V
  • OBD Operating Voltage: DC 9V ~ 16V
  • Consumption current: <70mA (6aV~9.5V -DC)
  • Operating temperature: -10℃ ~ 60 ℃
  • Storage temperature: -20℃ ~ 70℃
  • Receiving frequency:
    • 433.92 MHz ±50kHz
    • 315 MHz ±50kHz

Before Starting

Install App
Connect to WiFi. Download app by scanning QR codes.

Turn on O-Genius Lite
Press and hold the button for 3 seconds until 3 lights starts to flash.
Connect to Bluetooth

  1. 1. Open the Online App and the system will connect to Bluetooth.
  2. Select “Area”, “Language” and confirm “Privacy Policy”.
  3. Create an account.

Connect to Bluetooth
Make sure the Bluetooth light is on when you connect to Bluetooth.

Create a new account
Select “Registration”

Sign in
Key in all require information and click “Submit”. System will login automatically.

Read Sensor

Select “Check Sensor”

  1. This icon means “connecting OG-Lite”.
  2. This icon can show OG-Lite power.(*FAQ 14)

Select “Vehicle Selection”

Select Make, Model, YearOrange-Electronic-Lite-TPMS-Diagnostic-
Tool-10

Select “Read Sensor” Completed

Program

Select “Program” Select “Vehicle Selection”

Select Make, Model, Year Select Sensor Quantity Select “Trigger”

Select “Program”

Completed

ID Copy-Single program

Select “ID Copy” and “Vehicle Selection”

Select Make, Model, Year

Select “Single-program”

Three options to read sensor
3 ways to read new sensor. Use “Read Sensor” as an example.

Select “Read Sensor”

Select “ID Copy”

Completed Note: If the original sensor is broken, please select “Key in” function. Please follow the process below.Orange-Electronic-Lite-TPMS-
Diagnostic-Tool-27

ID Copy-Multi-program

Select “ID Copy” and “Vehicle Selection”

Select Make, Model, Year

Select “Multi-program”
3 ways to read new sensor. Use “Read Sensor” as an example. ****

Select “Read Sensor”

Read Sensor
Select the next tire to read sensor and repeat until all 4 sensors are complete.

Select “Next”

Select “ID Copy”

ID Copy
Select the next tire position and select “ID Copy”, repeat until complete

Completed

OBD Relearn

Select “OBD Relearn” and “Vehicle Selection”

Select Make, Model, Year

Select “Next”
Please follow the vehicle Relearn Procedure. (Reminder: different vehicle will have different procedure, it will determine the following steps) ****

3 options to read sensor
3 ways to read new sensor. use “Read Sensor” as an example. ****

Read new sensor IDs
Press new sensor position to read sensor.

Read new sensor IDs
Repeat procedure for other positions.

Select “OBD Relearn”

  1. Turn ignition to ON, engine off.
  2. Plug in O-Genius Lite.
  3. Select “OBD Relearn”

Completed

ID Copy (OBD)

Select “ID Copy(OBD)” and “Vehicle Selection”

Select Make, Model, Year

Plugin O-Genius Lite

  1. Turn ignition to ON, engine off.
  2. Plug in O-Genius Lite. ****

Select “Next”
O-Genius Lite will detect the sensor ID automatically, and select “Next”. ****

Select “ID Copy”

ID copy
Select the next tire position and select “ID Copy”, repeat until complete ****

Completed Relearn Procedure

Select “Relearn Procedure”

Select Make, Model, YearOrange-Electronic-Lite-TPMS-Diagnostic-
Tool-53

CompletedOrange-Electronic-Lite-TPMS-Diagnostic-
Tool-54

FAQ

Orange-Electronic-Lite-TPMS-Diagnostic-
Tool-55 Orange-Electronic-Lite-TPMS-Diagnostic-
Tool-56 Orange-Electronic-Lite-TPMS-Diagnostic-
Tool-57 Orange-Electronic-Lite-TPMS-Diagnostic-
Tool-58

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals