PHILIPS WL070V Ledinaire Wall Mounted Instruction Manual

October 27, 2023
Philips

PHILIPS WL070V Ledinaire Wall Mounted Instruction Manual

Ledinaire

Dimensions

Figure 1 and 2

Figure 3 and 4

Figure 5

HF Motion Sensor

(For WL070V LED17S MDU only)

By selecting the combination on the DIP switch, sensor data can be precisely set for each specific application.


Detection area
. (default 100%) show patterns.
Detection area can be reduced by selecting the combination on the DIP switches to fit precisely each application.


Hold time
. (default 5 min.)
Refers to the time period the lamp remains at 100% illumination after no motion detected


Daylight sensor
. (default 25 lux.)
The sensor can be set to only allow the lamp to illuminate below a defined ambient brightness threshold
When set to Disable mode, the daylight sensor will switch on the lamp when motion is detected regardless of ambient light level.
50 lux: twilight operation, 5 lux: darkness operation only


Stand-by dimming level
. (default 25%)
The low light level you would like to have after the hold time in the long absence of people.


Stand-by period
. (default 10 min.)
Refers to the time period the lamp remains at a low light level before it completely switches off in the long absence of people.
When set to ‘∞’ mode, the low light is maintained until motion is detected.

Detection Area

(radiation pattern)

Ceiling mounting

Ceiling mounting

Wall mounting:

Wall mounting

Notes:

  1. The Ledinaire Wall-mounted needs to be installed side-by-side in the same direction, The distance between each of the luminaires should be kept at least 3m to avoid mutual interference.

  2. Please pay attention to the installation environment:
    2.1. Avoid high-density objects such as: metal, glass, concrete walls, etc., within the sensor detection area.
    2.2. Avoid moving signals within the sensor detection area such as: fan, DC motor, sewer pipe, air outlet, heavy rainfall, motion behind a thin wall etc. This to avoid false triggers of the sensor.
    2.3 Avoid shock & vibration in the environment of the application.

  3. In order to reach the common sensor distance the object move speed should be less than 1m/S . If an object moves with speed higher than 1m/s the detection distance will decrease.

  4. It is advised not to install a luminaire on a wooden surface. In case it must be installed on a wooden surface, the wood thickness must be more than  15cm.

  5. To avoid smaller detection range or abnormal operation, the Ledinaire Wall-mounted should not be installed in close distance to large areas of metal and glass (separation distance at least 1 m).
    Please reduce detection area setting or contact Signify to confirm the situation once the Ledinaire Wall-mounted works fails.

© 2021 Signify Holding.
All rights reserved. This document contains information relating to the product portfolio of Signify which information may be subject to change. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V.. All other trademarks are owned by Signify Holding or their respective owners.

Signify Holding.
The Netherlands

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals