LIFAair LA503 Smart Air Purifier User Manual
- June 6, 2024
- LIFAair
Table of Contents
- Important safety information
- Packing List
- Function Description
- Function Description
- Initial Installation
- Use
- The Monitoring Controller Pairing with the Main Unit
- The Monitoring Controller Testing Items
- Short Time and Continuous Monitoring of the Monitoring Controller
- How to Operate the Monitoring Controller
- CO² Calibration
- Wi-Fi Network Connection
- Maintenance
- Specifications
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LA503 Smart Air Purifier
**User Manual
Designed in Finland**
Please read this user manual carefully before using it, it and keep it for
future reference.
Warning: Before using the machine for the first time, you must remove the
filters’ moisture-proof protective bags.
Thank you for choosing LIFAair! You are about to enjoy superior Finnish
technology and innovation.
Important safety information
- Only use attachments/accessories provided by the manufacturer.
- Keep the machine away from children to avoid accidents.
- Do not block any ventilation openings. Install the machine in accordance with the manufacturer’s instructions.
- Make sure the machine stands in the upright position, never operate the machine when in other orientations.
- Unplug the machine when it will not be used for a long period of time.
- Do not use this machine in rooms with large temperature differences to avoid vapor condensation inside.
- Protect the power cord from being walked on or pinched.
- Please switch off and unplug the machine before moving it or cleaning and/or replacing the filters.
- Do not use this machine in high temperature and/or humidity environments, such as bathrooms.
- Never open the power adapter to avoid electric shock and affecting the warranty.
- For user safety and product protection, do not sit or lean on the machine.
- Do not put any objects into the movable portion, the air inlet, and/or outlet.
- Do not place the product directly under air conditioning units to prevent condensed water droplets.
- Please do not attempt to disassemble and repair the product without the presence of professionals to avoid fire, electric shock, and being injured.
- To prevent electric shocks, be sure to follow this manual carefully for cleaning and maintenance. Please do not try to maintain the product otherwise.
- Please ensure to use the power supply unit provided with the appliance only.
Safety marking label of the main unit is on the bottom plate of the product.
Use only with the cart, stand, tripod, bracket, or table specified by the
manufacturer, or sold with the apparatus. When a cart is used, use caution
when moving the cart/apparatus combination to avoid injury from tip-over.
Correct disposal of this product. This marking indicates that this product
should not be disposed of with other household wastes throughout the EU. To
prevent possible harm to the environment or human health from uncontrolled
waste disposal, recycle it responsibly to promote the sustainable reuse of
material resources. To return your used device, please use the return and
collection systems or contact the retailer where the product was purchased.
They can take this product for environmentally safe recycling.
Power warning:
- Place the product near the power outlet for easy use.
- Before use, make sure that the operating voltage is the same as your local power supply. Correct operating voltage can be found on the product plate.
- For safety purposes, unplug the product during lightning storms or when unused for extended periods of time.
- Under normal conditions, the power supply may get hot. Please keep good ventilation in the area and exercise caution.
- Safety warning labels on the housing or bottom of the product or power adaptor.
This symbol is to alert the user to the presence of an un-insulated dangerous
voltage within the product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
This symbol is to warn the user not to disassemble the enclosure of the
product and there is no user-replaceable part inside. Take the product to an
authorized service center for repair.
This symbol indicates that the product is for indoor use only.
For wireless products:
- Wireless products may generate shortwave radio frequencies and interfere with the normal use of other electronic devices or medical equipment.
- Turn off the product when it’s disallowed. Do not use the product in medical facilities, on airplanes, at gas stations, near-automatic gates, automatic fire alarm systems, or other automated devices.
- Do not use the product in the vicinity of a pacemaker within a 20cm range. The radio waves may affect the normal operation of the pacemaker or other medical devices.
WARNING!
Danger of explosion if the battery is incorrectly replaced. Replace only with
the same or equivalent type.
For products with removable batteries, the battery must be properly recycled
or disposed of. For products with built-in batteries, disassembling is
prohibited.
Never disassemble, hit with force, squeeze batteries or dispose of batteries
in a fire. Do not expose batteries in conductive materials, liquid, fire, or
heat.
Do not let metal objects contact two battery poles. If the battery looks
swollen, leaking, discolored, having an odor, or any abnormal appearance, stop
using it. Do not use the battery after being immersed in water.
Improper use of battery may lead to explosion or leakage, causing skin burn or
other injuries; in the event of battery leakage, handle it with care and
immediately dispose of the battery in the manner in compliance with applicable
laws and regulations in your locality.
- This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
- Children are being supervised not to play with the appliance.
- The appliance is only to be used with the unit provided.
- Cleaning and user maintenance shall not be made by children without supervision.
- The appliance must only be supplied at safety extra-low voltage corresponding to the marking on the appliance.
Packing List
Function Description
Note: To avoid blocking the intake and exhaust area. Using plush fabric cushioning may clog the exhaust.
- Touch control surface: change fan speed and enter the pairing mode.
-
Working status/power indicator light
In case the Monitoring controller is not connectedGreenlight flashing slowly: standby mode
Greenlight flashing: response to touch control
Greenlight flashing rapidly: pairing with controller
Greenlight remains steady: operating mode
In case the Monitoring controller is connected
White light flashing slowly: standby mode
White light flashing: response to touch control
White light remains steady: operating mode - Air intake.
- DC power connector (connect to the power adapter).
- Bottom cover.
Function Description
Monitoring controller
Note 1: It is only enabled when connected with the main unit.
Note 2: To avoid affecting sensor accuracy, avoid blocking the intake and
opening. Using plush fabric cushioning may clog the exhaust.
- Main display screen
- Secondary display screen
- Touch button
To move the selection box or alter the value
Setting: press and hold: enter setting interface
press: return to the previous menu
Test: Press and hold to check the air quality for 5 minutes
Confirm: Click to confirm
Filter: click to enter filter use and filter reset interface
Main unit speed control: click to select the purifier’s fan speed mode (Note
-
Turn-ON/OFF / Black screen/light-up screen
Turn-ON/OFF: Press and hold
Black screen/light-up screen: press -
5V DC micro-USB power connector
-
PM2.5 sensor air inlet (Note 2)
-
PM2.5 sensor air outlet (Note 2)
-
Model identifications
S/N code: serial number of the monitoring controller (required for warranty)
CODE code: password for APP remote control.
Not case-sensitive.
Initial Installation
Connect the power supply
Remove the protective strip on the DC power connector, take out the power cord and connect to the power adapter. Connect the adapter to the main unit and then connect to the power source. The main unit will be in standby mode, LED lights will be flashing slowly.
Use
Correct positioning
To achieve the best possible performance of the air purifier, the air inlets
should maintain a certain distance from the walls and other obstructions when
using the purifier.
Manually control fan speed
The machine is designed with 121 wind speed and it can precisely control
the PM2.5 level.
Touch the top circle of the main unit and rotate clockwise to increase the fan speed (Continuously rotate clockwise until the power light remains constant indicating maximum fan speed).
Touch the top circle of the main unit and rotate counter-clockwise to reduce
fan speed (Continuously rotate counter-clockwise until the power light blinks
slowly in a breathing pattern for zero fan speed and enter standby mode).
Note: Above diagrams are for reference only, please prevail in kind.
The Monitoring Controller Pairing with the Main Unit
Pairing
The monitoring controller works collaboratively with the main unit through a
Bluetooth wireless connection, can be paired with LIFAair smart air purifiers
within a certain distance.
-
Press and hold the monitoring controller ON/OFF button to turn it on.
-
Slide anticlockwise on the touch circle of the purifier main unit to let the main unit blink green slowly, with one finger press and hold an icon ” ” on the touch circle for over 5 seconds until the green light flashes rapidly. The main unit will then enter pairing mode for 30 seconds.
Note: When pairing, the main unit must be in standby mode (green light slowly flashing; when the main unit flashes white, it has been successfully paired with the controller). -
Press and hold on to the controller, press to select“Purifier Pairing” , then press to confirm.
-
Press to move the selection box to“Yes” and press to confirm, the monitoring controller and main unit will enter auto-pairing mode.
-
After the pairing is successful, the main unit indicator light will turn white, and the monitoring controller will display “Paired”. The icon will appear at the top of the secondary display. If pairing is unsuccessful, please repeat the above steps.
The Monitoring Controller Testing Items
Your smart air purifier monitoring controller can monitor PM2.5, CO2, and TVOC
concentration.
When paired with LIFAair smart air purifiers, it can automatically control the
purifier main unit and maintain PM2.5 concentration in a healthy range.
It can also monitor temperature and humidity.
The monitoring controller will monitor air quality. There are six levels:
good, moderate, unhealthy for sensitive groups, unhealthy, very unhealthy, and
hazardous. American standards will be more stringent.
PM2.5 measurement
In the main interface press and switch to the “PM2.5” interface.
The Chinese standard requires the PM2.5 level to be below 35µg/m3.
- American standard requires the PM2.5 level to be under 12µg/m 3.
- It takes about 40 seconds for the value to stabilize.
CO² measurement
In the main interface press and switch to the “CO²” interface.
CO2 concentration will display on the monitoring controller, ≤ 1000ppm is
good.
When the concentration is over the standard level, it is recommended to open
the window for ventilation.
It takes about 40 seconds for the value to stabilize.
The average CO2 concentration in outdoor air is about 400ppm.
TVOC measurement
In the main interface press and switch to the “TVOC” interface.
According to current standards, AQI (air quality index) measurement doesn’t
account for TVOC. Thus, when the monitoring controller displays“good”, it
doesn’t indicate TVOC is under standard level. It takes about 40 seconds for
the value to stabilize.
Note: The monitoring controller uses a semiconductor sensor to measure
TVOC, it cannot replace professional instruments.
TVOC is divided into five levels:
Good: Moderate: Unhealthy: Very unhealthy: Hazardous:
Temperature measurement
In the main interface press and switch to the “TEMP” interface.
It displays the temperature at which the purifier main unit is located.
Note: To enable this function, please ensure the monitoring controller is connected with the LIFAair purifier main unit.
Humidity measurement
In the main interface press and switch to the “HUM” interface.
It displays the relative humidity at which the purifier main unit is located.
Note: To enable this function, please ensure the monitoring controller is connected with the LIFAair purifier main unit.
Short Time and Continuous Monitoring of the Monitoring Controller
Press and hold , the controller will continuously monitor air quality and will
display for 5 minutes. The“Test” icon will blink on the secondary display
screen. Press to exit this mode at any time during this process.
Note: After pairing with the unit (main unit
indicator light is white), the controller will regularly monitor air quality
and auto-control the operation of the main unit, regardless of what
aforementioned mode is selected.
How to Operate the Monitoring Controller
To enable fully autonomous operation, please ensure the monitoring controller is connected to the main unit.
-
Control the main unit: Press to enter speed mode selection interface (paired with the main unit), press to move selection box, and press to select different purification mode.
Purifier Off: Power on/off purifier.
Smart Mode: According to real-time indoor air quality, the monitoring controller will auto-adjust the main unit’s fan speed (recommended mode).
Manual Mode: Manually adjust the fan speed of the main unit; the fan speed will be held at a set value.
Night Mode: Fan will run at ultra-low noise level, to ensure a comfortable sleeping environment. Fan speed will remain at a constant speed.
Turbo Mode: Maximum fan speed, rapid purification.
Anti Allergy: The main unit will continue to run at a specified fan speed and will not be affected by PM2.5 concentration during this period. It is recommended to enable this function during flu or pollen season.
-
Press and hold to enter settings interface, press to select and press to confirm modification, then press again to return to the main interface.
Language: 中 → Chinese mandarin; EN → English.
Purifier Pairing: This can be paired with LIFAair smart air purifier.“No” is the default.
WiFi Login: Download LIFAair mobile APP to facilitate the process. Refer to P14-P16 for details.
Standard: Select the air quality standard (Chinese or American) as the purification standard; If the American standard is selected, the fan will operate at higher levels, especially at night.
Display Brightness: Adjust the screen brightness. Default is“Low”.
Auto-Brightness: The brightness of the monitoring controller and the main unit can vary according to the ambient light. If“Off”is selected, the monitoring controller display will be set at the lowest brightness when the surrounding is dark; if“On” is selected, the display screen of the controller will be off at this moment.“On” is the default.
Nightlight: If this function is enabled, at night when the monitoring controller enters the time display, touch any button the main display screen will all be lit and remain at the highest brightness for 3 minutes. Press any button to show corresponding content.“Off” is the default.
APP Control: Permit or forbid mobile phone APP to control the main unit. If“Off” is selected, APP can only view the monitoring controller display, it will not be able to control the monitoring controller.“On” is the default.
Purifier Control: Toggle touches control functionality on/off. To avoid accidental touch, turn touch control off.“On” is the default.
Night Eco: When turned on, the main unit will automatically decrease fan speed between 22:00-6:00 to reduce noise level and conserve energy. “On” is the default.
Time Setting: Select“Yes” and manually press buttons to adjust the time.“No” is the default. (Note)
Factory Settings: Select confirm, the monitoring controller will be restored to factory settings.“No” is the default. CO2 Calibration: Please follow the screen prompt to calibrate the CO2 value to zero, so as to ensure its accuracy Generally, it is unnecessary to calibrate.“No” is the default, and see P13 for details.
Note: The monitoring controller will automatically sync to the local time zone once connected to Wi-Fi via a cloud server. Please note this function maybe not be applicable in certain areas, please set the time manually if so. Filter checking -
Filter checking
LIFAair series smart purifiers all implemented advanced filter life-span calculation algorithms, which accurately calculate filter usage. Press to enters the filter monitoring interface, press to separately view each filter’s life status. The filter should be replaced when the monitoring controller indicates the filter’s capacity is less than 5%.
After cleaning or replacing the filter, please press to enter the filter reset interface. Select“Yes” to reset, the monitoring controller will then restart the monitoring process.
CO² Calibration
How to calibrate CO²:
CO2 sensors have been pre-calibrated. If there appears to be a systematic
error, proceed to recalibrate. Calibration method:
Place the monitoring controller outdoors, ensure sufficient ventilation. After
10 minutes, turn on the monitoring controller and perform two“Continuous
measurement” procedures. After the second“Continuous measurement”, wait for 3
minutes. Press and hold to enter the main interface, press to move selection
box to“CO2 calibration” and press to enter selection interface, then press to
select“Yes”and press again to calibrate CO2 value to 400ppm.
Note: If maloperation occurs, please select“Factory Settings” in the main menu to restore to default factory settings.
Warning
Main unit tilting:
Do not tilt the main unit during operation. If it is tilted over 45 degrees,
the monitoring controller screen will display such a warning, and the main
unit will stop operating until it is restored back to an upright position. The
warning icon will then also disappear.
Note:
-
When the monitoring controller is disconnected from its power supply, after each monitoring cycle the monitor will automatically enter standby mode.
The main and secondary displays will be off until the main power supply is connected. -
In standby mode, if the monitoring controller is paired with the main unit, the monitoring controller will still control and operate the main unit, despite the
display is off.
Wi-Fi Network Connection
http://www.lifa-air.com/en-gb/app
Note: To control the main unit via phone and to read data such as
temperature, humidity, filter life-span, etc. the monitoring controller must
be connected to the main unit.
Note: Due to product and software upgrades, the operation interfaces
shown on this manual may be slightly different from the actual product. If any
difference is found, the actual product prevails.
Maintenance
Filter Change (be sure the main unit is not operating, unplug the power cord and then proceed to clean/replace filters)
Prefilter Cleaning
To clean the prefilter, remove the two carbon barrels. Clean off the dust on
the outer surface of the carbon barrel. Please carry out this procedure
outdoors.
Reinstall the carbon barrels, and press the“Reset” button in the respective
controller interface to confirm.
Note: Do not use a wet towel to clean the prefilter to avoid clogging the
prefilter.
Specifications
Product Name: Smart Air Purifier
Model number: LA503
Particle Clean Air Delivery Rate (CADR particulate matter): 450m3 /h
Particle Cumulate Clean Mass (CCM particulate matter): P4 level
Particle Removal Efficiency: high efficient level
Formaldehyde Clean Air Delivery Rate (CADR formaldehyde): 240m3 /h
Formaldehyde Cumulate Clean Mass (CCM formaldehyde): F4 level
Formaldehyde Removal Efficiency: high efficient level
Noise: Night mode: 34dB (A)
Turbo mode: 66dB (A)
Application area: 31m2 ~54m 2
PM2.5 sensor: Laser type
TVOC sensor: Semiconductor type
Declaration for EU
Frequency Band (Wi-Fi): 2.412GHz-2.484GHz
Frequency Band (Bluetooth): 2.402GHz-2.480GHz
RF Power output: ≤20 dBm (EIRP)
There is no restriction of use.
Note: for application area, it is in accordance with GB/T18801-2015 calculated based on the value of CADR for particle. Performance data above are in accordance with GB/T18801-2015 tested by the third-party laboratories by using particular soot particles or gaseous pollutants as targeted pollutants.
Troubleshooting
Purifier not working?
Please check whether the power cord is correctly connected.
Please check whether the purifier is in minimum wind speed.
Please check whether the bottom cover is in the lock position.
Unable to connect the monitoring controller to the main unit?
Please follow the step-by-step instructions on Page 7- page 8“Pairing”to
connect.
Customer Service – International
If you have any questions, please contact us at care@lifa-
air.com or visit us at
www.lifaair.com
Please note: All rights to change or modify of the product without prior
notice are reserved.
Running noise?
Please check whether the filter is installed.
Please check whether the protective bags of the carbon barrels have been
removed.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>