GE APPLIANCES UVC7300 20 Inch Custom Insert Hoods with Dimmable LED Lighting Owner’s Manual

June 6, 2024
GE Appliances

GE-APPLIANCES

GE APPLIANCES UVC7300 20 Inch Custom Insert Hoods with Dimmable LED

Lighting

GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-
Lighting

THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every GE Appliances product, and we think you will too. Among other things, registration of your appliance ensures that we can deliver important product information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are available in the Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration card included in the packing material.

IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  • A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
  • B. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
  • C. Do not use this unit with any solid-state speed control device.
  • D. This unit must be grounded.

CAUTION
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.

CAUTION
TO REDUCE RISK OF FIRE AND TO PROPERLY EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE. DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL SPACES OR GARAGES.

WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:

  • A. SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
  • B. NEVER PICK UP A FLAMING PAN—You may be burned.
  • C. DO NOT USE WATER, including wet dishcloths or towels—a violent steam explosion will result.
  • D. Use an extinguisher ONLY if:
  1. You know you have a Class ABC extinguisher, and you already know how to operate it.
  2. The fire is small and contained in the area where it started.
  3. The fire department is being called.
  4. You can fight the fire with your back to an exit.

WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

  • A. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on medium settings.
  • B. Always turn hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
  • C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
  • D. Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  • A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • B. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
  • C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
  • D. Ducted fans must always be vented to the outdoors.
  • E. When applicable, install any makeup (replacement) air system in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions. In Canada, visit GEAppliances.ca.
  • F. Turn off breaker to adjacent rooms while working.

WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

How to Remove Protective Shipping Film and Packaging Tape
Carefully grasp a corner of the protective shipping film with your fingers and slowly peel it from the appliance surface. Do not use any sharp items to remove the film. Remove all of the film before using the appliance for the first time.To assure no damage is done to the finish of the product, the safest way to remove the adhesive from packaging tape on new appliances is an application of a household liquid dishwashing detergent. Apply with a soft cloth and allow to soak.
NOTE: The adhesive must be removed from all parts.
NOTE: For further cleaning instructions/suggestions, please refer to the Care and Cleaning section.

Controls

GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-
Lighting-1

  1. Rangehood Control Panel: The control panel is located on the front of the canopy. The position and function of each control button are noted below.
  2. Fan On/Off Button: On/Off switch for the fan. The fan can be operated by pressing any of the fan setting buttons. Hold for 3 seconds to activate Delay Off feature, which automatically turns the fan off after 15 minutes.
  3. Fan Setting Button : Speed control for the fan. Press the Low button for LOW speed, Med for MEDIUM speed, and High for HIGH speed. Hold down the High button for 3 seconds to activate the BOOST speed that will run for 10 minutes. On Remote, press up arrow to increase fan speed, press down arrow to decrease fan speed, including Boost.
  4. Light Button : On/Dim/Off switch for the LED lights. Press the Light button to turn the lights on, again to set the lights to dim setting, and again to turn the lights off.
  5. Chef Connect: This is a Bluetooth® pairing feature for use with other compatible Chef Connect enabled products on a cooktop or range. When the device is paired, the light and fan will turn ON at the Default Sync Settings upon receiving a command from the range or cooktop. It will remain ON at that setting until the user changes it. To pair devices, hold down the Chef Connect button for 3 seconds. To turn it back off, hold the button down for another 3 seconds, see the Chef Connect section for details.
  6. Chef Connect Indicator Light: Light will turn on when Chef Connect is paired.
  7. IR Sensor: Remote Control receiver when used with Remote Control Kit (UXRC1).
  8. Wi-Fi (Remote only): Not available.
  9. Delay Off (Remote only): Press and hold Delay Off to toggle Delay Off function.

Heat Sensor
Your hood is equipped with a HEAT SENSOR thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.
When the temperature level drops to normal, the blower will return to its original setting. 49-2000893 Rev. 0

Chef Connect

Chef Connect Operation Bluetooth® Connection

To pair with another device:
To start the pairing process on the hood, press and hold the Chef Connect button for 3 seconds. The backlight for the Low-Med-High-Light-Chef Connect buttons will flash in that sequence until the hood is paired with the range or other device. If the pairing is successful, all five backlights (Low, Med, High, Light, Chef Connect) will flash simultaneously three times and then turn off and the Chef Connect indicator light will turn on. It will time out after 2 minutes if the pairing is not completed, after which the pairing sequence will need to be restarted.

To cancel pairing:
To cancel the pairing, hold the Chef Connect button down for 3 seconds and then turn off the hood.

Default Sync Settings:

  • The factory default setting for the light will be the brightest.
  • The factory default setting for the fan sync will be OFF.
  • The user can change the Default Sync Settings by pressing and holding the Low button for 3 seconds. This will enter the Default Settings Mode. Once in this mode, the backlights for all buttons (Low, Med, High, Light, Chef Connect) will blink On/Off indefinitely and the fan and light will switch to the current Default Sync Setting, so the user knows what the current default value is.
  • At this time, set the light and fan to the desired default levels. Once the user is satisfied with the selection, press and hold the Off button for 3 seconds. This will exit this mode. At that time the backlights will stop blinking and the state of the fan and light will change back to their prior state before entering the Default Settings Mode.

Filters

Be sure the circuit breaker is off and all surfaces are cool before cleaning or servicing any part of the vent hood. The metal filters trap grease during cooking. The filter must ALWAYS be in place when the hood is in use. The grease filter is dishwasher-safe and should be cleaned every month, depending on the usage of the hood.

Mesh Metal Grease Filter

To remove:
Press filter latch in and pull down.GE-APPLIANCES-UVC7300-20-Inch-Custom-
Insert-Hoods-with-Dimmable-LED-Lighting-2

To replace:
Insert the bottom of the filter tabs into the corresponding holes. Press filter latch in and lift up into place. Release the latch to lock it in place.

To clean:
Swish the filter in hot soapy water and rinse in clean water or wash it in the dishwasher. Do not use abrasive cleansers.
NOTE: Some discoloration of the filters may occur in the dishwasher.

Charcoal Filter (for recirculation installation only)

NOTE: DO NOT rinse, or put charcoal filter in an automatic dishwasher.
The charcoal filter cannot be cleaned. It must be replaced. It is recommended that the charcoal filter be replaced every 6 months or if it is noticeably dirty or discolored.

Order Charcoal Filter UXCF91 (not included)
To inquire about purchasing replacement charcoal filters or to find the location of a dealer nearest you, please call our toll-free number: National Parts Center 800.626.2002

To Install

  1. Remove the grease filters. See Filters section.
  2. Install the charcoal filter mounts to either side of the motor using three screws per side.
  3. Insert the tab on the charcoal filter into the triangular slot on the mount.
  4. Clip the charcoal filter in until it is locked
  5. Repeat with second filter on the other side of the motor.
  6. Reattach the metal filters. See Filters section.

To Remove

  1. Remove grease filters-See Filters section
  2. Unclip the charcoal filter by pressing the release clip.
  3. Carefully remove charcoal filter from tab.

GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-
Lighting-3

Surfaces

Stainless Steel Surfaces (on some models)
Do not use a steel wool pad; it will scratch the surface.
To clean the stainless steel surface, use warm sudsy water or a stainless steel cleaner or polish. Always wipe the surface in the direction of the brush line. Follow the cleaner instructions for cleaning the stainless steel surface. Cleaners with oxalic acid such as Bar Keepers Friend Soft Cleanser™ will remove surface rust, tarnish, and small blemishes. To receive a coupon for a trial sample of Bar Keepers Friend Soft Cleanser™ follow the link below or scan the

QR Code.GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-
Dimmable-LED-Lighting-4

Use only a liquid cleanser free of grit and rub in the direction of the brush lines with a damp soft sponge. To inquire about purchasing stainless steel appliance cleaner or polish, or to find the location of a dealer nearest you, please call our toll-free number:

National Parts Center
800.626.2002
GEApplianceparts.com

CAUTION
Allow lights to cool before touching.

  1. Before attempting to replace the lights, make sure that the light switch is turned off.
  2. Rotate light counterclockwise to unlock and pull out. Wearing latex gloves may offer a better grip.
  3. Replace with new light of same type, making sure pins are inserted properly into the sockets of the lamp holder and turn clockwise to lock. All lamps need to be GU10 compatible.GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-Lighting-5

Installation Instructions

If you have questions, call GE Appliances at 800.GE.CARES (800.432.2737) or visit our website at: GEAppliances.com. In Canada, visit GEAppliances.ca or call 800.561.3344.

BEFORE YOU BEGIN
Read these instructions completely and carefully.

IMPORTANT — Save these instructions for local inspector’s use.
IMPORTANT — Observe all governing codes and ordinances.

  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Skill level – Installation of this vent hood requires basic mechanical and electrical skills.
  • Completion time – Approximately 1 to 3 hours
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty

CAUTION
Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product, TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION

FOR YOUR SAFETY
WARNING Before beginning the installation, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  • A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • B. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
  • C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
  • D. Ducted fans must always be vented to the outdoors.
  • E. Turn off breaker to adjacent rooms while working.

WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.
WARNING Disconnect all electrical power at the main circuit breaker or fuse box before installing

Installation Preparation

PRODUCT DIMENSIONS

GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-
Lighting-6

CABINET PREPARATION Liner (Optional) (UXHL30 or UXHL36)GE-APPLIANCES-
UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-
Lighting-7

INSTALLATION CLEARANCES

This vent hood must be installed between the 24″ required minimum and 36″ recommended maximum above the cooking surface.

  • always refer tot he cooktop of range installation instructions for product-specific clearances.
    NOTE: Installation height should be measured from the cooking surface to the bottom edge of the cabinet surface.
    NOTE: UL requires any combustible surface to be a minimum of 30″ above the cooking surface.

  • The custom cabinet internal height must be 16-5/8″ minimum for vertical venting, 27-1/8″ for recirculation. If liner is used, the custom cabinet internal height must be 20-5/8″ minimum for vertical venting, 31-1/8″ for recirculation.

  • The hood can be vented to the outdoors  so it can be installed for recirculating operation. For recirculating operation, refer to Recirculating Installation Planning.

GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-
Lighting-8

Installation Preparation

TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED)

GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-
Lighting-9

PARTS PROVIDED

Locate the parts packed with the hood.
NOTE: The hardware bag may contain extra pieces to accommodate a variety of installation methods for various models.GE-APPLIANCES-UVC7300-20-Inch-
Custom-Insert-Hoods-with-Dimmable-LED-Lighting-10

PLAN THE INSTALLATION

CAUTION To reduce risk of fire and to properly exhaust air, be sure to duct the air outside – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

WARNING
PERSONAL INJURY HAZARD
It is recommended that 2 people are used to install the range hood. Failure to properly lift rangehood could result in damage to the product or personal injury.
NOTE: This rangehood can be installed as either ducted or recirculation. In a ducted application, this rangehood can be vented through the wall or ceiling. When installed for recirculation, the rangehood vents back into the room.

REMOVE THE PACKAGING
CAUTION Wear gloves to protect against sharp edges.

  • Remove the hardware bag, literature package and other boxed parts.
  • Remove and properly discard the protective plastic wrapping and other packaging materials
ADVANCE PLANNING

Plan the route for venting exhaust to the outdoors. To maximize the ventilation performance of the vent system:

  1. Minimize the duct run length and number of transitions and elbows.
  2. Maintain a constant duct size.
  3. Seal all joints with duct tape to prevent any leaks.

When applicable, install any makeup (replacement) air system in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions .GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-
Lighting-11

Custom Cabinet Frame Planning
The custom canopy or cabinet should have a rectangular hole to accommodate the custom hood insert by itself. This hole is the same size for both a wall installation and an island installation. Ensure parallelism and levelness of the cabinet so that it doesn’t affect flushness of the hood with the cabinet GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-
Lighting-12

RECIRCULATION INSTALL PLANNING
This hood may be installed in recirculation mode. The charcoal filter (not included) is necessary for recirculation installation

POWER SUPPLY

IMPORTANT – (Please read carefully)
WARNING
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. Follow National Electrical Codes or prevailing local codes and ordinances.

Electrical supply

  • These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.
  • Wiring must be 2 wire with ground.
  • If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding.
  • Route house wiring as close to the installation location as possible in the ceiling or wall.
  • Connect the wiring to the house wiring in accordance with local codes.

Grounding instructions
The grounding conductor must be connected to a ground metal, permanent wiring system, or an equipment-grounding terminal or lead on the hood.

PREPARE HOUSE ELECTRICAL WIRING
The custom cabinet must allow spacing for house wiring to reach junction box located in diagram below. If unit is installed over an island, the wiring must come from ceiling. If power cord is needed, accessory is available.

PREPARE FOR CABINET INSTALLATION

NOTE: This bracket must be removed prior to installation. Remove 2 back (rear) and 2 bottom screws per illustration bellow.GE-APPLIANCES-UVC7300-20
-Inch-Custom-Insert-Hoods-with-Dimmable-LED-Lighting-14

  1. 1. Securely press the damper on top of the exhaust opening. Check that the damper opens freely. Attach damper to hood using screws (B) provided.
  2. The hood should be centered left to right over the cooktop.
  3. Remove and properly discard the protective plastic wrapping from the hood.
  4. The back surface of the hood must be 1″ minimum from the back wall. The front surface of the hood must be 3″ minimum from the front custom cabinet panel.
  5. The custom cabinet should provide for removal of panels to provide access to the electrical wiring and to the ducting and its connections to the hood in case of any need for servicing or other reasons.

Installation

INSTALL HOOD LINER (If Used)
  1. The rectangular opening in framing or custom cabinet must be sized for the liner outside and inside dimensions. Refer to Product Dimensions section.
  2. Secure the liner to the cabinet with 4 wood screws (A) or (D) as needed.GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-Lighting-16
INSTALL THE HOOD
  1. Confirm the damper is in place in the hood exhaust opening.
  2. Insert the hood into the cabinet opening.GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-Lighting-17
  3. Fasten with 8 screws (A or L), 4 in the back and 2 on each side. It is recommended to start with one corner and fasten screws diagonally to ensure unit flushness with cabinet. If the liner is used, fasten 12 machine screws (B), 4 in the back, 4 in the front, and 2 on each side. The front 4 screw holes are accessed by removing the light panel assembly. The light panel assembly is removed by removing the two screws on both ends of the panel.
  4. Once the hood is in place, seal the duct to the hood with duct tape (Do not use screws).

ELECTRICAL CONNECTION

  1. Remove the electrical junction box cover.
  2. Remove the electrical box knockout.
  3. Feed the Power Supply Cable through the hole and secure with a strain relief.
  4. Attach the white lead of the power supply (A) to the white lead of the range hood (D) with a wire nut. Attach the black lead of the power supply (B) to the black lead of the range hood (C) with a wire nut. Connect the house ground wire under the green grounding screw (E).GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-Lighting-22
  5. Reattach the electrical junction box cover.
RECIRCULATION KIT (If Used)
  1. Cut a hole into the soffit for the exhaust duct.
  2. Install the vent grill over the exhaust duct.
  3. Seal the duct joints with duct tape.

Visit GEAppliances.com to order the optional recirculation kit. In Canada, vision GEAppliances.ca.

GE-APPLIANCES-UVC7300-20-Inch-Custom-Insert-Hoods-with-Dimmable-LED-
Lighting-23

FINALIZE INSTALLATION
  1. Insert filters, see the Filters section.
  2. Check operation of the lights and blower.
  3. Finish the custom cabinetry.

Troubleshooting tips

Save time and money! Review the charts on the following pages first and you may not need to call for service.

Problem Possible Cause What To Do
Fan/Light does not operate when button is turned ON A house fuse may be
blown or a circuit breaker tripped. Replace fuse or reset circuit breaker.
Loud or abnormal airflow noise Wrong duct size used in installation.

This hood requires 8” ducting to perform optimally. Using smaller duct pipe will cause reduced venting. Minimize the duct run length and number of transitions and elbows. GE Appliances service technicians cannot correct this issue if installed improperly.
Fan fails to circulate air or moves air slower than normal and/or

fan is making loud or abnormal airflow noise

| Obstructions in duct work.| Make sure nothing is blocking the vent. Make sure your wall or roof cap has a blade or door.
Damper blade on wall or roof cap may not be open.| Make sure damper swings freely. Damper blades may flip over and will not fully open when this happens.

Adjust to original position.

Metal grease filter and charcoal filter (if present) may be dirty.| Clean the metal grease filter and replace charcoal filter (if present). See Care and Cleaning of the Vent Hood.
Insufficient makeup (replacement) air| Sufficient makeup (replacement) air is required for exhausting appliances to operate to rating. Check with local building codes, which may require or strongly advise the use of makeup air. Visit GEAppliances. com for available makeup air solutions. In Canada, GEAppliances.ca.
Early light failure| Light wattage is too high.| Replace with correct wattage.
Fan keeps going off and on| The motor is probably overheating and turning itself off. This can be harmful to the motor.| Check to be sure the filters are clean. If off and on cycling continues, call for service.
Lights not functioning| Wrong bulbs are used. Must use GU10 compatible dimmable bulbs.| Visit GEAppliances.comfor replacement bulbs. In Canada, GEAppliances.ca.

GE Appliances Vented Range Hood Limited Warranty

GEAppliances.com
All warranty service is provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service online, visit us at GEAppliances.com/service_and_support/, or call GE Appliances at 800.GE.CARES (800.432.2737). In Canada, visit GEAppliances.ca/en/support/service-request or call 800.561.3344. Please have your serial number and your model number available when calling for service.
Servicing your appliance may require the use of the onboard data port for diagnostics. This gives a GE Appliances factory service technician the ability to quickly diagnose any issues with your appliance and helps GE Appliances improve its products by providing GE Appliances with information on your appliance. If you do not want your appliance data to be sent to GE Appliances, please advise your technician not to submit the data to GE Appliances at the time of service.

EXCLUSION OF IMPLIED WARRANTIES
Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This limited warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Appliances Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Appliances Service location for service. In Alaska, the limited warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
Warrantor: GE Appliances, a Haier company
Louisville, KY 40225

Extended Warranties: Purchase a GE Appliances extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it online anytime at In US: geappliances.com/service_and_support/shop-for-extended-service- plans.html In Canada: geappliances.ca/en/support/purchase-extended- warranty

Accessories

Looking For Something More?
GE Appliances offers a variety of accessories to improve your cooking and maintenance experiences! Refer to the Consumer Support page for phone numbers and website information. The following products and more are available:
Parts

  • Power Cord Kit
  • Recirculation Kit
  • Charcoal Filter
  • Hood Liner
  • Remote Control

Cleaning Supplies

  • CitruShine™ Stainless Steel Wipes
  • Stainless Steel Appliance Cleaner
  • Bar Keepers Friend Soft Cleanser™

Consumer Support

GE Appliances Website
Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! You can also shop for more great GE Appliances products and take advantage of all our on-line support services designed for your convenience. In the US: GEAppliances.com. In Canada: GEAppliances.ca.

Register Your Appliance
Register your new appliance on-line at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material. In the US: GEAppliances.com/register.
In Canada: Prodsupport.mabe.ca/crm/Products/ProductRegistration.aspx

Schedule Service
Expert GE Appliances repair service is only one step away from your door. Get on-line and schedule your service at your convenience any day of the year. In the US: GEAppliances.com/service or call 800.432.2737 during normal business hours. In Canada: GEAppliances.com/en/support/service- request

Extended Warranties
Purchase a GE Appliances extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it on-line anytime. GE Appliances Services will still be there after your warranty expires. In the US: GEAppliances.com/extended- warranty or call 800.626.2224 during normal business hours. In Canada: GEAppliances.com/en/support /purchase-extended-warranty

Remote Connectivity
For assistance with wireless network connectivity (for models with remote enable), visit our website at GEAppliances.com/connect or call 800.220.6899 in the US.

Parts and Accessories
Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on line today 24 hours every day.
In the US: GEApplianceparts.com or by phone at 877.959.8688 during normal business hours.
In Canada: GEAppliances.com/en/products/parts-filters- accessories
Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.

Contact Us
If you are not satisfied with the service you receive from GE Appliances, contact us on our Website with all the details including your phone number, or write to:
In the US: General Manager, Customer Relations | GE Appliances, Appliance Park | Louisville, KY 40225 GEAppliances.com/contact
In Canada: Director, Consumer Relations, Mabe Canada Inc. | Suite 310, 1 Factory Lane | Moncton, N.B. E1C 9M3 GEAppliances.ca/en/contact- us

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GE Appliances User Manuals

Related Manuals