LUCCI 213280 DC Ceiling Fan Instruction Manual
- June 6, 2024
- Lucci
Table of Contents
- THANK YOU FOR PURCHASING
- **SAFETY PRECAUTIONS
- PARTS LIST
- INSTALLING THE FAN
- HANGING THE FAN
- ELECTRICAL WIRING DIAGRAM THE FAN
- FINISHING THE INSTALLATION
- USING YOUR CEILING FAN
- AFTER INSTALLATION
- CARE & CLEANING
- SAFETY PRECAUTIONS FOR BATTERY
- TECHNICAL INFORMATION
- LUCCI CEILING FAN WARRANTY DETAIL
- CEILING FAN WARRANTY INFORMATION
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
213280 DC Ceiling Fan
Instruction Manual
CAUTION
READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION.
THANK YOU FOR PURCHASING
Thank you for purchasing the latest in energy-saving ceiling fans. This fan runs on DC (direct current) power which gives it the benefit of being super energy efficient whilst still maintaining high volume air movement and silent operation.
Energy-saving – The DC motor is the latest technology in fan design. Its highly efficient motor saves up to 65% more energy than ceiling fans with traditional AC motors.
Silent operation – This DC fan motor is programmed with a stabilized current which efficiently reduces motor noise.
Low operating temperature – The DC power is managed effectively which brings down the motor operating temperature to less than 50℃. This results in a much cooler motor than a standard AC fan and increases the longevity of the motor.
6-speed remote control – Regular AC ceiling fans usually come with only 3 speeds, this DC fan comes complete with a 6 speed remote, which gives a greater choice of comfort levels.
**SAFETY PRECAUTIONS
**
- The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
-
An all-pole disconnection switch must be incorporated into the fixed wiring, in accordance with local wiring rules.
WARNING:
FOR SAFE USE OF THIS FAN AN ALL-POLE DISCONNECTION MUST BE INCORPORATED INTO THE FIXED WIRING IN
IN ACCORDANCE WITH THE WIRING RULES.
As outlined in clause 7.12.2 of AS/NZS 60335-1 for meeting the minimum electrical safety of this standard.
Please note warranty will be void if installation is without a means for an all-pole disconnection incorporated in the fixed wiring in accordance with the wiring rules. This fan is suitable for indoor, alfresco, and coastal areas where the fan is fully undercover with a minimum of 1 wall. This fan is not waterproof. When installed in an alfresco or coastal area, the ceiling fan must be positioned in a location protected from water, wind, and dust. Exposure to these elements will void the warranty. Mounting the fan in a situation where it is subject to water or moisture is dangerous.
Example: If a fan is connected to a circuit that can be isolated via an
all-pole safety switch at the switchboard, then this is considered to be
anall- pole disconnection to the ceiling fan electrical circuit, meeting the
requirements of clause 7.12.2 of AS/NZS 60335.1.
A single-pole switch on the activities of the receiver input of remote
control must also be included in the wiring and located in the same room as
the ceiling fan.
-
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. -
The structure to which the fan is to be mounted must be capable of supporting a weight of 18 kg.
-
The fan should be mounted so that the blades are at least 2.1m above the floor.
-
This fan is suitable for indoor and alfresco areas where the fan is fully undercover with a minimum of 2 walls. This fan is not waterproof. When installed in an alfresco area, the ceiling fan must be positioned in a location protected from water, wind, dust, and salt. Exposure to these elements will void the warranty. Mounting the fan in a situation where it is subject to water or moisture is dangerous and may increase the risk of damage, injury, or electrical shock.
-
Must be assembled and installed by a licensed electrician.
-
WARNING: If unusual wobbling or oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent, or suitably qualified persons.
-
The replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent, or suitably qualified persons.
-
The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with sufficient strength to withstand 4 times the weight of the ceiling fan; the mounting of the suspension system shall be performed by the manufacturer, its service agent, or suitably qualified persons.
PARTS LIST
- Unpack your ceiling fan carefully. Remove all parts and hardware.
- Layout all the components on a smooth surface and make sure there are no components missing before assembling. If parts are missing, return the complete product to the place of purchase for inspection or replacement.
- Check whether the ceiling fan has been damaged during transport. Do not operate/install any product which appears damaged in any way. Return the complete product to the place of purchase for inspection, repair, or replacement.
- Examine all parts (LED lamp is Not Included), you should have the following:
1.| Mounting bracket x1 set| 6.| Mounting bracket screws x2 Blades
screws x7 pcs
---|---|---|---
2.| Fan assembly x1 set| 7.| Balance kit x1 set
3.| Bottom cover x1 pcs| 8.| Receiver x1
4.| LED lamp x1 pcs (Not Included)| 9.| Light kit extension cable x1
(For use with an extension down rod)
5.| Blades x3 pcs| 10.| Remote controller x1 set
INSTALLING THE FAN
TOOLS REQUIRED:
- Phillips / flat head screwdriver
- Pair of pliers
- Adjustable spanner
- Step ladder
- Wirecutter
- Wiring, supply cable as required by local provincial and national wiring codes and regulations
INSTALLING THE MOUNTING BRACKET
- The ceiling fan must be installed in a location so that the blades are spaced 300mm from the tip of the blade to the nearest objects or walls.
- Install the hanging bracket to the ceiling joist or structure that is capable of carrying a load of at least 18 kg, with two long screws provided. Ensure at least 30mm of the screw is threaded into the support. (Fig. 2)
NOTE: The bracket screws provided are for use with wooden structures only. For structures other than wood, the appropriate screw-type MUST be used. Ensure the screws used are suitable for the mounting surface and the surrounding environment.
ANGLED CEILING INSTALLATION
This fan hanging system supports a maximum 13 degree angled ceiling
installation. (Fig. 3)
INSTALLATION OF BLADE (Fig. 4)
-
Install the fan blade to the fan assembly by tightening the 2 screws.
Ensure all screws are tightened evenly to reduce the chance of warping or unbalancing.
Take care not to over-tighten the screws, as this can damage the blades -
Repeat the same process for the other blades.
INSTALLATION OF Lamp (optional) (Fig. 5)
- Install the lamp on the fan assembly then secure it by turning clockwise.
Note: Compatible LED Lamp SKU# 121354 & 121359 are not included
INSTALLATION OF Bottom cover (Fig. 6)
- If no lamp is required, Install the bottom cover to the fan assembly then secure it by turning clockwise.
HANGING THE FAN
Lift the fan assembly onto the mounting bracket. Ensure the key slot (A) of the hanger ball is positioned on the key pin (B) of the mounting bracket (C) to prevent the fan from rotating when in operation. (Fig. 7)
ELECTRICAL WIRING DIAGRAM THE FAN
PREPARE AND COMPLETE THE ELECTRICAL WIRING — WIRING DIAGRAM (FIG. 8)
WARNING: FOR YOUR SAFETY ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY
A LICENSED ELECTRICIAN.
NOTE: AN ADDITIONAL ALL-POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE
FIXED WIRING.
NOTE: IF THERE ARE TWO OR MORE DC CEILING FANS INSTALLED IN THE ONE
LOCATION, AN AN ISOLATION SWITCH IS REQUIRED FOR EACH CEILING FAN. THIS IS
REQUIRED WHEN PROGRAMMING THE REMOTE AND RECEIVER TO PAIR TOGETHER.
NOTE: Ensure the motor earth wire is connected to the single earthing
terminal block “1” in the diagram below (Fig. 8).
From mains supply to mounting bracket terminal block: (Fig. 8)
-
Connect the live supply wire to the “L” terminal of the terminal block on the mounting bracket.
-
Connect the neutral supply wire to the “N” terminal of the terminal block on the mounting bracket.
-
Connect earth wire to the earth terminal of the terminal block on the mounting bracket.
From mounting bracket to receiver and motor: (Fig. 8) -
Connect the supply wiring from the mounting bracket to the input of the DC motor driver/receiver.
-
Connect the output wires of the DC motor driver/receiver to the input wires of the fan motor and the light kit.
-
Connect the earth wire of the DC motor driver/receiver to the single earthing terminal block “1” in the diagram below.
Carefully insert the Remote Receiver above the hanger ball in the remainder
spacing in the mounting bracket.
Take care not to damage or loosen any of the wirings. (Fig. 9).
FINISHING THE INSTALLATION
- After completing the electrical connection at the mounting bracket terminal block, connect the ceiling fan wiring via the quick connector plug.
NOTE: Ensure the earth wiring is secure and correct, by performing an earthing continuity test from the fan’s accessible metal body back to the earth terminal at the terminal block on the mounting bracket.
INSTALLATION OF THE CANOPY (Fig. 10)
- Loosen the 2 screws at the bottom of the mouthing bracket.
- Slide the canopy up to the mounting bracket and align the keyholes on the canopy with the screws on the mounting bracket. Turn the canopy until it locks into place with the narrow section of the keyholes and secure it by tightening the two screws. Avoid damaging the electrical wiring prepared previously.
- Slide the canopy cover ring up to the canopy and click in to cover the canopy cover screws.
INSTALLATION OF THE REMOTE CONTROL HOLDER (Fig. 11)
- Locate a suitable wall to fix the remote control holder with the 2 screws. (Fig.11a).
- Slide the remote into the holder to rest the remote. (Fig. 11b)
USING YOUR CEILING FAN
NOTE: The remote and receiver will need to be paired after the installation
of the ceiling fan.
NOTE: When two or more ceiling fans are installed in one location, please
refer to the instruction on the next page.
Install the 3V CR2032 DC battery in the compartment. Please make sure the
polarity of the battery is correct.
(Fig. 12)
PAIRING REMOTE & RECEIVER – WHEN 1 DC CEILING FAN IS INSTALLED IN ONE LOCATION
NOTE: Ensure that you have installed a single-pole disconnection switch
in the fixed wiring for the fan.
NOTE: Ensure power to the receiver is ON prior to pairing the remote with
the receiver.
-
Turn OFF the mains supply to the fan by an on/off wall switch.
-
Install the batteries into the remote. Please make sure the polarity of the battery is correct.
-
Turn ON the power to the receiver.
-
Press and hold the “ ” button on the remote for 3-5 seconds within 30 seconds of switching the power ON to the receiver of the ceiling fan.
If the fan has a light kit attached, the light will flash on and off to indicate the pairing process is activated. -
Turn ON the fan and change the speed of the ceiling fan via the remote to check the operation and successful pairing.
-
If pairing has been unsuccessful, repeat this set of steps again.
PAIRING REMOTE & RECEIVER – WHEN 2 OR MORE DC CEILING FANS ARE INSTALLED IN
ONE LOCATION
When two or more fans are located near each other, you may want to have the remote/receiver for each fan set to a different code, so that the operation of one fan does not affect the operation of the other fan/s.
NOTE: Ensure that you have installed a single-pole disconnection switch
in the fixed wiring for each fan.
NOTE: Ensure power to the receiver is ON prior to pairing the remote with
the receiver.
Remote / Receiver pairing for Ceiling fan 1:
-
Turn OFF the mains supply to the receivers of both ceiling fans 1 and 2.
-
Install the 3V DC battery in the compartment. Please make sure the polarity of the battery is correct.
(Fig.12) -
Turn on the power to receiver 1. Keep the power OFF to receiver 2. (Each ceiling fan must have its own
isolation switch, so that only the ceiling fan that needs to be paired with the remote will be ON). -
Press and hold the “ ” button of remote 1 for 3-5 seconds within 30 seconds of switching the power ON to the receiver of ceiling fan 1.
If the fan has a light kit attached, the light will flash on and off to indicate the pairing process is activated. -
Turn ON and change the speed of the ceiling fan 1 by the remote to check the operation and successful pairing.
-
If pairing has been unsuccessful, repeat this set of steps again.
Remote / Receiver paring for Ceiling fan 2:
-
Turn off the mains supply to the receivers of both ceiling fans 1 and 2.
-
Install the 3V DC battery in the compartment. Please make sure the polarity of the battery is correct.
(Fig.12) -
Turn on the power to receiver 2. Keep the power OFF to receiver 1. (Each ceiling fan must have its own isolation switch so that only the ceiling fan that needs to be paired with the remote will be ON).
-
Press and hold the “ ” button of remote 2 for 3-5 seconds within 30 seconds of switching the power ON to the receiver of ceiling fan 2.
If the fan has a light kit attached, the light will flash on and off to indicate the pairing process is activated. -
Turn ON and change the speed of ceiling fan 2 by the remote to check the operation and successful pairing.
If pairing has been unsuccessful, repeat these set of steps again
Remote Control Buttons (Fig. 13)
1 – FAN SPEED CONTROL BUTTON:
There are 6 available speeds. The “ I ” button is for the lowest speed,
and the “ VI ” button is for the fastest speed.
NOTE: when you turn on the fan for the first time or switch the main
power to the controller, you need to start the fan on high “VI” speed first
and then choose a lower speed. 5-10 seconds is required to allow the DC fan to
respond to the remote for each speed or fan direction selection.
2 – FAN OFF BUTTON:
Press the button to turn the fan off.
3 – REVERSE FUNCTION BUTTON:
Press the button to activate the reverse running function. The fan must be
operating to activate the reverse function.
4 – LIGHT CONTROL BUTTON:
Press the button to turn the light ON/OFF.
The LED light has a 3-step dimmable function which is controlled by an ON/OFF
switch.
When the LED light is ON and at 100% brightness, press the light button “ON
and then OFF within 5 seconds”, to dim the LED light. Repeat pressing ON and
then OFF within 5 seconds to dim further in the following sequence: 100%
brightness → 50% brightness → 20% brightness → 100% brightness.
To switch back to 100% brightness at any stage, turn OFF the luminaire, and
then wait after 5 seconds turnON the luminaire, it will reset to 100%
brightness.
REPAIRING THE REMOTE & RECEIVER PAIRING – WHEN 1 CEILING FAN IS INSTALLED
- If the remote and receiver lose control after installation or during use, the pairing of the remote and the receiver must be repaired.
- Below are the operating symptoms and the steps to repair the pairing of the remote and receiver.
Symptoms:
- Loss of control – Fan is only running at high speed after installation
- Loss of control – No reverse function after installation
- Loss of control – Remote cannot communicate with the receiver
Repairing Steps:
A. Switch OFF the main power to the ceiling fan for 30 seconds.
B. Press and hold the “ ” button on the remote for 3-5 seconds within 30
seconds of switching the power ON to the receiver of the ceiling fan.
C. Turn ON and change the speed of the ceiling fan via the remote to check the
operation and successful pairing.
THE RECEIVER PROVIDES THE FOLLOWING LEVEL OF PROTECTION:
-
Lock position: the receiver has a built-in safety feature to protect against obstruction during operation.
The motor will be locked from the operation and will disconnect from power after 30 seconds of interruption.
Please remove obstacles before re-starting. To reset, simply turn off the power supply to the fan motor and re-start. -
Over 80W protection: when the receiver detects power consumption that is greater than 80W, the receiver power will be stopped and operation will immediately discontinue. Turn the receiver power on after 5 seconds to restart the fan.
AFTER INSTALLATION
NOTE: Ceiling fans tend to move during operation due to the fact that
they are mounted on a rubber grommet.
If the fan was mounted rigidly to the ceiling it would cause excessive
vibration. Movement of a few centimeters is quite acceptable and DOES NOT
suggest any problem.
TO REDUCE THE FAN WOBBLE: Please check that all screws which fix the mounting bracket and down rod are secure.
BALANCING KIT: A balancing kit is provided to balance the ceiling fan on initial installation. Please refer to the instruction on how to use the balancing kit. The balancing kit can be used to assist re-balancing should the ceiling fan become un-balanced again. Store your balancing kit away after installation for future use if required.
NOISE:
When it is quiet (especially at night) you may hear occasional small noises.
Slight power fluctuations and frequency signals superimposed in the
electricity for off-peak hot water control may cause a change in fan motor
noise. This is normal. Please allow a 24-hour “settling-in” period, most
noises associated with a new fan disappear during this time.
The manufacturer’s warranty covers actual faults that may develop and NOT
minor complaints such as hearing the motor run – All electric motors are
audible to some extent.
CARE & CLEANING
NOTE: Always turn OFF the power at the mains switch before performing any maintenance or attempting to clean your fan.
- Every 6 months periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush or lint-free cloth to avoid scratching the paint finish. Please turn off electrical power when you do so.
- Do not soak or immerse your ceiling fan in the water or other liquids. It could damage the motor or the blades and create the possibility of an electrical shock.
- Ensure that the fan does not come in contact with any organic solvents or cleaners.
- To clean the fan blade, wipe with only a damp clean cloth with NO organic solvents or cleaners.
- The motor has a permanently lubricated ball bearing so there is no need for oil.
SAFETY PRECAUTIONS FOR BATTERY
- WARNING – Keep new and used batteries away from children.
- CAUTION – Do not ingest battery—Chemical burn hazard.
- Always use 3V CR2032 DC battery type with this ceiling fan remote controller.
- Ensure the batteries are inserted with the correct polarity.
- To prevent false operation during battery insertion or replacement, this ceiling fan must be disconnected from the supply mains.
- Remove batteries from the product when not in use for long periods of time.
- Batteries must be removed from the remote transmitter before it is discarded.
- Dispose of exhausted batteries immediately and safely (so they cannot be retrieved by children). Batteries can still be dangerous. Contact your local council to safely dispose of the battery.
- Regularly check the product and make sure the battery box lid is correctly secured. If the battery compartment does not close securely, stop using the product, and keep it away from children.
- If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. If you suspect your child has swallowed or inserted a button battery, immediately call the 24-hour Poisons Information Centre on 13 11 26 for fast, expert advice.
- Battery Leaks: Battery contains chemicals and should be treated as any chemical would. Take precautions when handling leaked battery chemicals. Battery chemicals should not be placed near the eyes or ingested. Contact Poisons Information Centre on 13 11 26 for fast, expert advice.
TECHNICAL INFORMATION
Fan
Fan Models| 56″ DC fan – PEREGRINE
---|---
LD-PERE -FAN / SKU# 213280 , 213281,213282
Rated Voltage| 220-240V— 50Hz
Rated Wattage (Motor)| 38W
Rated wattage (Lamp)| GX53 (SKU#121354 / SKU#121359) , Max.12W ( not included)
Battery for remote Weight
Canopy Dimensions| 3V CR2032 (Included)
4.4 kg
H:55mm Dia:142mm
LUCCI CEILING FAN WARRANTY DETAIL
LUCCI WARRANTY HOTLINE- 1800 602 243
THIS WARRANTY IS VALID IN AUSTRALIA ONLY
In the event of service is required, please call the Lucci Fan Warranty
Hotline on 1800 602 243 between 9 am & 5 pm (EST) Monday to Friday. Please
make sure you have all the ceiling fan details filled out at the end of the
manual before making the call.
Every Lucci ceiling fan is thoroughly inspected and tested before being
released for sale. In addition to any warranty rights or conditions under
statutory regulations, Lucci warrants all of its ceiling fans against
defective workmanship and faulty materials for twenty-four (24) months from
the date of purchase. Lucci undertakes, at its option, to repair or replace,
free of charge, each product or part thereof on condition that;
- The fan or relevant part has not been subjected to misuse, neglect, or being involved in an accident.
- The repairs are not required as a result of normal wear and tear.
- The product was installed by a licensed electrical contractor.
- A copy of the original receipt of purchase is presented.
- A 12-month warranty applies when used in any non-domestic applications.
- This warranty does not cover stains, scratch and scuff marks, or dents if the product is purchased through a factory outlet or to refurbished items.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Lucci Design cannot be held responsible for any repair other than those carried out by it or one of its Authorised Service Agents. Please keep this warranty information in a safe place. This information must be produced in the event of service being required.
Distributed by:
Beacon Lighting
140 Fulton Drive
Derrimut, Victoria, 3026
Australia
Ph +613 9368 1000
Fax +613 9360 9332
Email: warranty@beaconlighting.com.au
CEILING FAN WARRANTY INFORMATION
LUCCI WARRANTY HOTLINE- 1800 602 243
Complete and retain this form for your personal records and warranty purposes.
NAME……………………………………………………………………………………………………..…
ADDRESS……………………………………………………………………………………………..……
……………………………………………………POSTCODE……………………………………………
MODEL NUMBER………………………………………………………………………………………..…
(PO# + DATE CODE Sticker here)
PO NUMBER or DATE CODE …………………………………………………………………………….
DATE OF PURCHASE………………………………………………………………………………….…
INSTALLING LICENSED ELECTRICIAN……………………………………………………………..…
LICENCE No………………………………………………………………………………….……………
ATTACH PROOF OF PURCHASE HERE
THIS COMPLETED DETAIL PAGE SHOULD BE PRODUCED AND FAXED TO THE WHOLESALER OR THEIR AUTHORISED AGENTS BEFORE OBTAINING WARRANTY SERVICE
Read User Manual Online (PDF format)