TASK Power LP30HR15NDGSN30 Lighted Power Strip Instruction Manual
- June 17, 2024
- TASK power
Table of Contents
- TASK Power LP30HR15NDGSN30 Lighted Power Strip
- General Guidelines
- Wiring for Combined Light and Receptacle Circuit – Non Dimmable
- Wiring for Separate Light and Receptacle Circuits
- Wiring Diagram for Combined Light & Receptacle Circuit – Non-Dimmable
- Wiring Diagram for Separate Light & Receptacle Circuits
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TASK Power LP30HR15NDGSN30 Lighted Power Strip
General Guidelines
- Power source MUST be a 20 amp branch circuit protected by a GFCI at the panel or GFCI prior to the connection at LPS.
- All wiring must meet NEC® and local codes.
- Light valance recommended.
- Firmly insert plug straight into receptacle, applying equal pressure to both blades at the same time. Gently rock plug, if needed.
Turn power off at panel. Carefully pry open each piece with tool (provided). Insert Romex connector into knockout hole inside of back frame. Pull wires into LPS.
Wiring for Combined Light and Receptacle Circuit – Non Dimmable
Step 1
Secure LPS to wall by screwing into wall studs or use the anchors provided.
Connect BLACK Romex wire to BLACK wire from receptacles and switch. Connect
WHITE Romex wire to WHITE wire from receptacles and driver. Ground all GREEN
wires to PEM studs inside of back frame.
Step 2
When connecting 2 or more LPS fixtures, run Romex from fixture to fixture.
Ground each section to the next.
Step 3
To terminate last LPS, use wire nuts on ends of the wires.
Step 4
Snap cover in place and turn power on.
Wiring for Separate Light and Receptacle Circuits
Step 1
Secure LPS to wall by screwing into wall studs or use anchors provided. If
running two circuits, one for receptacles, one for lighting, connect fixtureN
wires to appropriate Romex wires. BLACK to BLACK. WHITE to WHITE. Ground all
GREEN wires to PEM studs inside of back frame.
Step 2
When connecting 2 or more LPS fixtures, run Romex from fixture to fixture.
Ground each section to the next.
Step 3
To terminate last LPS, use wire nuts on ends of wires.
Step 4
Snap cover in place and turn power on.
Wiring Diagram for Combined Light & Receptacle Circuit – Non-Dimmable
Wiring Diagram for Separate Light & Receptacle Circuits
- Customer Service: 800-445-6404 www.TaskLighting.com
- Design Services & Tech Support: 866-848-9094 DesignAndSupport@TaskLighting.com