OneEvent THERMONEW433 Thermo One Refrigeration Sensor Instruction Manual
Thermo One™ Refrigeration Sensor
Package Contents:
- Thermo One Sensor (x1)
- Mounting Clip (x1)
- L91 AA Lithium Batteries (x2)
- Installation Instructions (x1)
- 3M™ VHB mounting tape (x1)
INSTRUCTIONS
-
Remove the battery cap screw from the bottom of the sensor enclosure.
-
Install both AA lithium batteries into the battery enclosure, noting proper polarity.
-
Install and secure the battery cap screw.
The sensor will begin transmitting at 4 second intervals in order to facilitate gateway setup and positioning. -
Determine the mounting location by considering: a. Location of cooler venting and airflow.
Note: Do not install in corner of cooler.
b. Minimize obstructions to gateway.
c. Vertical orientation of the sensor provides best signal strength.
d. Locate at least 1 inch from metal surfaces if possible. -
Use included clip and mount into racking with zip ties or mount to side of cooler with VHB tape.
Note: To remove clip slide toward base of sensor. -
Ensure the gateway is operating and connected to the OneEvent server.
-
Allow a short time to elapse for the sensor to connect to the gateway, then verify the sensor is reading in the OneEvent app.
-
Once installed, no user interaction is required.
INSTALLATION TROUBLESHOOTING
It is imperative that the sensors can communicate with a OneEvent™ gateway.
The number of walls, ceilings and metal objects in the signal path reduces the
strength of the radio frequency (RF) signals
between the sensor and the gateway. Accordingly, some sensors may have
difficulties communicating to the assigned OneEvent gateway. It may be
necessary to move the gateway closer to the sensor if
notifications are not being received during installation testing.
Installation testing begins after installing the batteries and ends by
confirming the sensor reading on the OneEvent app. The test mode transmits a
signal every 4 seconds for 60 minutes, after which
the Thermo One™ Refrigeration sensor reverts to the default transmit cycle of
3 minutes.
LIMITATIONS OF OET RF SIGNALS
OneEvent™ radio communication systems are reliable and are tested to high
standards. However, due to their low transmitting power and limited range (as
required by regulatory bodies) there are some
limitations to be considered: Receivers may be blocked by radio signals
occurring on or near their operating frequencies (i.e. signals from garage
door openers).
· Changes in the surrounding environment (renovations or furniture that has
been moved), can disrupt radio communications between the sensor and gateway.
Changes and modifications to this device not approved by OneEvent® Technologies could void the user’s authority to operate the equipment. If your sensor fails to work after you have read the previous sections, please contact your Dealer or OneEvent. If you receive a “Low Battery” alert, immediately replace them with (2) AA lithium batteries. Use of any other type will effect sensor function.
TECHNICAL SPECIFICATION
Operating frequency: 433 MHz
Range: 100m in free air (min)
Protocol: OneEvent™ RF Link
Transmit interval: 3 minutes ± 15 seconds
Sensor message duration: 20ms
OET-100413 weight: 77 grams, including batteries
FCC COMPLIANCE STATEMENT
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation. Note: the grantee is not responsible for
any changes or modifications not expressly approved by the party responsible
for compliance. Such modifications could void the user’s authority t o operate
the equipment.
FCC ID: 2AHZG-THERMONEW433
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.