ASTE FINLAND LUMIO 90 F Lumio Series Impulse Freezer User Manual

June 6, 2024
ASTE FINLAND

ASTE FINLAND LUMIO 90 F Lumio Series Impulse Freezer

OVERVIEW

Aste constantly works on the further development of all models. Therefore please understand that we have to reserve the right to make design, equipment and technical modifications.

SAFETY INSTRUCTIONS

Please read this operating and maintenance manual carefully. We suggest to keep the guide into your possession during the entire life cycle of the product.

After delivery, immediately check the appliance for possible transport damage and make sure it works properly. All safety devices must be present and functional before operating the appliance.

Do not leave children without supervision. Ensure that they do not play with the appliance. In the case of appliances provided with locks, the key must be kept at a site where children cannot have access to it to avoid unintentional locking.

ASTE-FINLAND-LUMIO-90-F-Lumio-Series-Impulse-Freezer-
FIG-1

INSTALLATION AND USE

  • The appliance always has to be transported and displayed vertically.
  • The appliance is designed for inside use only.
  • The surroundings should not transcend the following conditions (based on a standard environment):
    • 25°C temperature
    • 60% humidity
    • 0,2 m/s air speed

ASTE-FINLAND-LUMIO-90-F-Lumio-Series-Impulse-Freezer-
FIG-2

Keep a minimum distance of 10 cm between the appliance and neighboring surfaces (walls, roof, furniture etc.).
Keep clear of obstructions all ventilation openings in the appliance enclosure or for built-in structure.

Before connecting the device, check:

  • The power rating (on the type plate)
  •   The relevant local electrical safety regulations

Do not use an extension cord to connect the appliance to the electrical circuit.

Make sure that the power cable and plug are undamaged before connecting the appliance. The damaged cable can only be replaced with a cable identical to the original part.

After delivery, keep the appliance in a warm ambient temperature for 2 hours before starting it.

Do not use electrical appliances inside the storage compartments of the appliance, unless they are of the type recommended by the manufacturer.

Do not store explosive substances such as aerosol cans with a flammable propellant in the appliance. The user is solely responsible for damages to properties or products, or injuries to persons resulting from careless and improper use of the appliance.

Do not expose the appliance into direct sunlight. Do not heat the appliance to more than 70°C.

DEFECTS}
Only authorized service specialists may perform work on the electrical and refrigeration systems. If this is not observed, all warranty and liability claims become invalid. Damaging the refrigerant circuit can lead to severe injuries. Do not damage the refrigerant circuit!

WHEN OUT OF USE

  • Make sure that the appliance is thoroughly cleaned and dried. Proper cleaning prevents corrosion and mold formation.
  • Appliances out of use may be dangerous for children, therefore position the appliance in such manner that no person can get locked up.
  • When disconnecting the appliance from the power supply, always take hold of the plug. Do not pull the cable.

ASTE-FINLAND-LUMIO-90-F-Lumio-Series-Impulse-Freezer-
FIG-6

PUTTING INTO OPERATION

INSTALLATION

IMPORTANT!
Never move the appliance by grasping the handle of the lid.

Position the device where it is protected from sunlight and other heat sources, since operation may be disturbed if the ambient temperature exceeds +25°C.

  • The appliance should not be operated in rooms where the temperature drops below +10°C since this disrupts the lubrication of the compressor.

Leave at least 10 cm space between the appliance’s sidewalls/roof/back and neighboring surfaces such as other devices, walls, furniture, and ceiling to provide free air flow behind the device to enable proper operation. If the furnishing of the room allows positioning only close to the heat source the following minimum clearances must be kept:

  •  Put a 0.5-1 cm thick insulation board between two devices if they are 3 cm or less apart.
  •  Min. 30 cm from oil or coal-fired ovens.

IMPORTANT!
If the humidity is above 60%, condensation may occur on the glass.

ELECTRICAL CONNECTION
The appliance may be connected to 220-240 V, 50 Hz mains via a properly mounted grounded socket. Check if the voltage meets the local voltage and make sure that the connecting cable isn’t stuck anywhere.
A fuse/circuit breaker of 10 A is required for the operation of the appliance.

  • If the connection cable is damaged or it has to be extended, the job must be done by a qualified electrician to avoid dangerous situations.

Do not use an extension cord! The appliance must be positioned in a way that the main plug is easily accessible.

USE OF THE APPLIANCE

STARTING UP

IMPORTANT!
All packaging materials are recyclable/energy waste.

  1. Make sure that all packaging material and foreign objects are removed from the appliance.
  2.  Clean the appliance with detergent before switching it on, dry it with a soft, clean cloth and let it ventilate for a while.
  3.  It is advised to keep the appliance in an upright position for at least 2 hours after transport before using it.
  4.  It is advised to switch on the appliance and check its operation before positioning it at the final place.
  5.  Leave the appliance connected in an empty state for 2 hours to check the functioning before adding goods for the first time. Do not load food to be frozen before the temperature display reads -18°C.

SET OF DIVIDERS

ASTE-FINLAND-LUMIO-90-F-Lumio-Series-Impulse-Freezer-
FIG-7

DIVIDERS INSTALLATION (DEFAULT SETUP)

IMPORTANT!
Wear safety gloves during the installation.

  1. Make sure there are no foreign objects present in the food storage of the appliance.
  2.  Position the slotted basement profiles inside the appliance. Insert transversal dividers into the profiles.
  3.  Make sure T-shaped profiles are placed in the middle. Please note the orientation of L-shaped profiles. Insert lateral dividers into slots in the basement profile.

ASTE-FINLAND-LUMIO-90-F-Lumio-Series-Impulse-Freezer-
FIG-8

  •  Insert lateral dividers into slots in the basement profile.
  •  Make sure the dividers have prescribed distance between each other. Distances are indicated by the number of empty slots of the basement profile and can be customized if needed.

ASTE-FINLAND-LUMIO-90-F-Lumio-Series-Impulse-Freezer-
FIG-9

  •  Secure the dividers using clips. Apply them all the way down at the point of the intersection of lateral and transversal dividers. Check that clips are securely positioned.

ASTE-FINLAND-LUMIO-90-F-Lumio-Series-Impulse-Freezer-
FIG-10

DIGITAL CONTROLLER

HINT!
The digital temperature controller is located in the lower part of the appliance, close to the power cable.

ASTE-FINLAND-LUMIO-90-F-Lumio-Series-Impulse-Freezer-
FIG-11

  • Select the desired target temperature by pressing or Turn lights ON/OFF by pressing Press and hold for 3 seconds to switch ON or  turn OFF the appliance.
  • Start defrosting by pressing and holding for 3 seconds.
  • Thawing is fully automatic. It is recommended to defrost and clean the appliance every 3 months (see chapter 4. Cleaning and Maintenance).

FILLING
To achieve optimal cooling, it is advised to fill up the appliance when it is less frequently used, since the frequent opening of the appliance hinders cooling of its contents.

  1.  Check the maximum load.
  2.  Do not overload the device with products. Inside you will see line indicators that show the maximum level.
  3.  Be careful not to block air circulation.

ASTE-FINLAND-LUMIO-90-F-Lumio-Series-Impulse-Freezer-
FIG-12

IMPORTANT!
Always mind the maximum load (see chapter 6. Technical Specifications).

ENERGY-SAVING TIPS

HINT!
Do not place the appliance in direct sunlight, HVAC outlets or near heat- producing appliances (like ovens, boilers and heaters).

  • The appliance reaches its top efficiency when it works 24/7, do not switch it off during the night.
  • Always close the lid.
  • Level the appliance, so the lid closes tightly. The appliance will run with higher energy efficiency.
  • Keep your appliance clean and well maintained: dust on the condenser or any unsolved problem can cause increased energy consumption.
  • Fill the appliance according to the prescribed instructions to allow energy-efficient operation.
  • Wipe goods dry before placing them in the appliance. This cuts down on moisture build-up inside the appliance.
  • Turn off the interior lighting of the appliance for the night.
  • Maintain and clean the appliance in a proper way. If the condenser coil is not cleaned at least 4 times per year, the efficiency of the appliance will decrease significantly.

IMPORTANT!
Once the appliance is switched off, or in case the power is cut off, wait for at least 5 minutes before plugging in again to avoid damaging the compressor or cooling system of the appliance.

WARNING!
Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the current user manual.

CLEANING AND MAINTENANCE

IMPORTANT!
Lack of maintenance will cause the appliance to break down.

PREPARATION

  1.  Remove or relocate the appliance’s contents.
  2.  Disconnect the appliance from the mains.
  3.  Remove lids to allow free air circulation.
  4.  Let the appliance defrost for 12 hours.

ASTE-FINLAND-LUMIO-90-F-Lumio-Series-Impulse-Freezer-
FIG-13

CLEAN INSIDE/OUTSIDE

IMPORTANT!
Do not clean the appliance with high-pressure or steam cleaners.

  •  Remove inner glass to reach all surfaces.
  •  Clean the inside and outside of the appliance with water and non-aggressive detergent.
  •  Dry previously cleaned surfaces with a soft, clean and dry cloth.

ASTE-FINLAND-LUMIO-90-F-Lumio-Series-Impulse-Freezer-
FIG-14

IMPORTANT!
Wear safety gloves to avoid the danger of injury during cleaning.

CLEAN CONDENSER

IMPORTANT!
Only the ventilation grating to the condenser may be opened. Only a trained specialist may open other covers of the appliance.

  • The front grill is mounted to the frame with five screws located close to its edges.
  •  Remove the ventilation grating by pulling it out to reach the condenser.
  •  The condenser must be cleaned at least 4 times a year with a brush or vacuum cleaner. Make sure that fins are not damaged or bent.

ASTE-FINLAND-LUMIO-90-F-Lumio-Series-Impulse-Freezer-
FIG-15

RE-INSTALL

  •  Install ventilation grating, inner glass and lids back.
  •  Connect the appliance to the main circuit.
  •  Switch on the appliance.
  •  Put contents back in after 1 hour.

TAKING THE APPLIANCE OUT OF SERVICE

Empty the appliance’s contents and pull out the power plug.
Make sure that the appliance is thoroughly cleaned and dried. Thus mould formation and corrosion are prevented.
The appliance out of use may be dangerous for children, therefore remove its lid or position the appliance in such manner that no person can get locked up.

IMPORTANT!
Secure loose parts of the appliance before moving it to the storage.

TROUBLESHOOTING

Problem Possible causes Remedy
The appliance does not operate The appliance is not switched ON. Switch ON

the appliance
The power plug is not plugged in correctly| Reconnect the appliance to the power supply in a correct way
Power relay tripped| Wait for at least 5 minutes then restart the appliance
The power cable/plug is damaged| Contact the seller or your local service provider
The airflow is restricted| Check the distance

between the appliance and its surroundings / Nothing blocks the

airflow inlets/outlets /

Condenser is not dirty

The fuse is blown/the circuit breaker tripped| Replace the fuse/reset the circuit breaker
The electronic board may be defective| Contact the seller or your local service provider
Water condensation on surfaces| Too high ambient temperature and/or relative humidity %| Install the appliance in an adapted environment
Appliance gets too cold /

Ice formation on inner surfaces

| Too low ambient temperature| Install the appliance in an adapted environment
The temperature regulation may be incorrect| Contact the seller or your local service provider
LED lights do not operate| The appliance is not switched ON| Switch ON the appliance
Lights are turned OFF| Switch ON lights using the digital controller
LED lights are burned out| Contact the seller or your local service provider
Problem| Possible causes| Remedy
---|---|---
Unpleasant smell| Re-evaporation tray is dirty| Contact the seller or your local service provider
Appliance’s

performance level of cooling is not enough

| Too high ambient temperature and/or relative humidity %| Install the appliance in an adapted environment
The airflow is restricted| Check the distance

between the appliance and its surroundings / Nothing blocks the

airflow inlets/outlets / Condenser is not dirty

The lid is not closed correctly| Close the lid correctly
The lid gasket does not seal properly| Clean the gasket from dirt
Wrong temperature setting| Check temperature

settings using electronic display

Disturbing noise /

Disturbing vibration

| The gurgling sound is produced by the flow of refrigerant| Such sound is normal
Popping and cracking sounds are produced by the contraction

and expansion of refrigerant

| Such sounds are normal
The surface under the appliance is not flat

enough

| Position the appliance

steadily on a flat surface

The appliance is not levelled correctly| Level the appliance to

ensure that its position is steady

Problem Possible causes Remedy
The digital controller does not operate The appliance is turned OFF Switch

ON the appliance
The electronic board may be defective| Contact the seller or your local service provider
The lid does not close properly| The lid gasket does not seal properly| Clean the gasket from dirt.
The lid gasket is

flattened since it was

squeezed between the appliance body and

the lid

| Unflatten the gasket by gently pulling it off
The dividers are not properly positioned| Make sure dividers are positioned in a proper way
The appliance is not levelled correctly| Level the appliance to ensure that it stands upright
Excessive ice formation in the evaporator area| Too high ambient temperature and/or relative humidity %| Install the appliance in an adapted environment
The lid is not closed correctly| Close the lid correctly
The lid gasket does not seal properly| Clean the gasket from dirt
The heating element may be defective| Contact the seller or your local service provider

In case the malfunction is not caused by any of the above-mentioned factors or persists over a long period of time or in order to order spare parts*, please contact the seller, your local service partner or get in touch with our after- sales service:
+358 (0)29 7020 0150 or via e-mail: [email protected]
The minimum period during which spare parts, are necessary for the repair of the appliance is 8 years after placing the last unit of the model on the market

TECHNICAL SPECIFICATIONS

Type LUMIO ® 90 F LUMIO ® 145 F LUMIO ® 185 F
Net Weight 89 kg 170 kg 250 kg
Gross Volume 200 l 470 l 620 l
Net Volume 87 l 195 l 270 l
Max Load per Side 24 kg 70 kg 70 kg
Width (external) 625 mm 1456 mm 1873 mm
Depth (external) 900 mm 895 mm 895 mm
Height (external) 930 mm 927 mm 935 mm
Power Input 250 W 920 W 920 W
Defrosting Automatic Automatic Automatic
Defrosting Input 490 W 1800 W 1800 W
Avg. Consumption 5.5 kWh/24h 14.4 kWh/24h 18.3 kWh/24h
Classification* 3L1 3L1 3L1
Temperature range -25°C … -18°C -25°C … -18°C -25°C … -18°C
Factory Setting -21°C -21°C -21°C
Energy Class D E E
Compressor Embraco Embraco Embraco
Refrigerant R290 R290 R290
Temperature Control Digital Digital Digital
Evaporator Finned Coil Finned Coil Finned Coil
Condenser Material Steel Aluminium Aluminium
Condenser Type Bent Wire Maint. Free Maint. Free
Lighting LED LED LED
Cable Length 3 m 5 m 5 m
Service Frequency 36 months 36 months 36 months

You can find the detailed explanation of product classification according to applicable standard using the link: www.astecoolers.com/products

ENVIRONMENTAL POLICY & RECYCLING
Environmental awareness is key throughout the complete life cycle of our products: from designing to producing it to finally recycling it.
We keep a close eye on the economical and effective use of new environmentally friendly materials in our products and production. Our target is to minimise the use of non-renewable natural resources.
We are convinced that sustainable production is the only correct way of working with respect for our customers, consumers and our planet today and in the future.
We strongly advise you to visit www.astecoolers.com/products to check the optimal storing temperatures for food and beverages. Incorrect temperature setting may result in spoilage and food waste.

DISPOSING OF THE APPLIANCE

WARNING!
The thermal insulation material is EPP.

The appliance contains some reusable materials and should be disposed of properly — not simply with unsorted household refuse. Appliances that are no longer needed must be disposed of in a professional and appropriate way, in accordance with the current local regulations and laws.
Please check your obligations in accordance with the national WEEE* provisions and the local WEEE disposal partner. Ensure that the piping is not damaged in the process.
Both insulating material and the coolant of the appliance bought by you are environment-friendly materials, which do not damage the ozone layer around the globe in any form.
Waste Electrical and Electronic Equipment Directive

The warranty terminates upon:**

  •  outside & wrong usage
  •  not following the instructions
  •  negligence of maintenance

The minimum duration of the warranty is 12 months. For more information, please contact the seller, your local service partner, or get in touch with our after-sales service:
+358 (0)29 7020 0150 or via e-mail: [email protected]

DETAILED PRODUCT INFORMATION
Detailed product information is available from the European product database (EPREL).

  1.  Use the QR code on the rating plate to find the product information from EPREL.
  2.  You can also access the EPREL using the link: https://eprel.ec.europa.eu/
  3.  You will be asked to enter the model ID. You can find the model ID on the rating plate.

HINT!
You can find product specifications, hints, recommendations, product cards and other helpful information from www.astecoolers.com

Aste Finland Oy Koskivuorenkatu 5 30420 FORSSA – FINLAND
[email protected] Tel. +358 (0)2 970 200 160
www.astecoolers.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ASTE FINLAND User Manuals

Related Manuals