equation TH40DP6 Digital Programmable Room-Temperature Thermostat Instruction Manual

June 6, 2024
equation

TH40DP6 Digital Programmable Room-Temperature Thermostat
Instruction Manualequation TH40DP6 Digital Programmable Room-
Temperature Thermostat

DIGITAL PROGRAMMABLE ROOM-TEMPERATURE THERMOSTAT, WIRED FOR BOILERS., WALL- MOUNTED.

equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
1| equation
TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
2
---|---
equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
3| equation
TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
4
equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
5

INTRODUCTION

The room thermostat turns the heating system on and off to obtain the desired temperature (set temperature). It detects the air temperature and compares it with the set temperature. If the room temperature is lower than the set temperature, the thermostat turns on the boiler, and turns it off when the set temperature is reached, and so on.
Energy efficiency is ensured by a self-learning TPI control algorithm, which adapts to the environment and provides tight temperature regulation with minimal energy consumption.
To obtain an optimum setting, set a low temperature (18°C for example) and increase degree by degree each day to reach the temperature that suits you (comfort temperature).
The thermostat does not affect the power of the boiler, so there is no need to set a higher temperature to heat faster.
If the radiators have valves (manual or thermostatic) make sure that the radiators located in the same room as the thermostat are open.
The thermostat is compatible with modulating boilers, but with a reduction in performance. It is compatible with floor heating system is included in a full system by a specialist (hot water control should be managed by another system)

INSTALLATION

The thermostat must be installed on a wall away from any source of heat (fi replace, radiator, sun) and drafts (window, door), at a height of 1.2 m to 1.5 m.
It must be connected to the inputs for an “ON/OFF” remote thermostat (T1 and T2) of a boiler, regardless of the polarity. The diagram on the label stuck in the box corresponds to the particular case of a series connection to the boiler supply. In this case, it is important to connect phase (L) to terminal A of the thermostat.
The installation must be carried out by a person possessing the required qualifi cations while respecting the national wiring standards in force.
Inserting batteries

  1. Push the cover of the battery compartment in the direction of the arrow in order to remove it.
  2. Insert 2 AA (LR06) 1,5V batteries in the compartment. Make sure you observe the right polarity (“+” and“-”).
  3. Place the cover of the battery compartment back.

Important!

equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
6

  • Do not let children play with batteries
  • Do not ingest batteries
  • Non-rechargeable batteries are not to be recharged;
  • Different types of batteries are not to be mixed;
  • New and used batteries are not to be mixed;
  • Batteries are to be inserted with the correct polarity;
  • Exhausted or leaking batteries are to be removed from the appliance and safely disposed of;
  • If the appliance is to be stored unused for a long period, the batteries should be removed;
  • The supply terminals are not to be short-circuited;
  • The batteries must be removed from the appliance before it is scrapped.

USE

Displaysequation TH40DP6 Digital Programmable Room-Temperature
Thermostat - figure 7

Controls and navigationequation TH40DP6 Digital Programmable Room-
Temperature Thermostat - figure 8

First start-up
When inserting the batteries for the first time, it is necessary to set the user’s language, the date and time, and the type of programming.

|
---|---

  1. Choose the language using the and keys

  2. Press (Right key) to validate.

  3. the indication is displayed and the year is flashing

  4.  Set the year using and keys

  5. Press to validate.
    equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
11

  6. Set the month using and keys.

  7. Press to validate.

  8. Set the day using and keys.

  9. Press to validate.

  10. Set the hour using and keys.

  11. Press to validate.

  12. Set the minutes using and keys.

  13. Press to validate, the indication is displayed and the type of programming is flashing. Set the programming type using and keys The programming type “7d” allows to set different time ranges for each day of the week.
    The programming type “5-2” proposes a setting for weekdays (from Monday to Friday) and another one for weekends (Saturday and Sunday).

  14. Press to validate.

Operating modes

Several operating modes are available:

  • AUTO : The thermostat follows the pre-recorded internal programs for each day of the week. These programs defi ne which temperature to set for each of the 6 time ranges of the day. It is possible to customize these programs.
  • MAN (Manual): The thermostat constantly monitors the set temperature using the and   keys.
  • OFF (Frost Protection Mode): The thermostat maintains a temperature above 5°C to protect against freezing.

Change Operating mode

  1. Press (right key) to put the thermostat in Frost Protection Mode, which is displayed.
  2. Press again to activate the thermostat, disappears.
  3. Press (central key) to switch between AUTO and MANUAL modes.
    It is not possible to activate AUTO or MANUAL mode when the thermostat is in OFF mode.

equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
14

AUTO mode programs
The AUTO mode allows 6 temperature level changes that can be programmed for each day between 12:00 am and 11:50 p.m. Each temperature level can be set between 5 ° C  and 35°C by steps of 0.5°C. The default programs are :equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
15

Customize programs

  1. Press MENU (left key) to enter the Programmation menu , symbol and indication are flashing
    equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
16

  2. Press (right key) to validate, the first day is displayed and its number is flashing.

  3. Choose the day to change using and keys If the “5-2” programming type has been chosen when first startup, only “MO: FR” and “SA: SU” options can be changed.

  4. Press to validate, the first time range is fl ashing, the trigger time and the set temperature are displayed.

  5. Choose the first time range to change using the and keys

  6. Press to validate, the trigger time is flashing

  7. Set the time using the and keys

  8. Press to validate, the temperature is flashing

  9. Set the temperature using the and keys
    equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
17

  10. Press to validate.

  11. Go back to point 5 for each of the other time ranges

  12. Go back to point 3 for each of the other days or copy the day (see below) At each time, it is possible to go back to the previous step by pressing (Left key)

Copying time ranges from one day to another
equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
18

  1. Press MENU (left key) to enter the Programmation menu, symbol and indication are flashing
  2. Press (right key) to validate, the first day is displayed and its number is fl ashing.
  3. Choose the day to copy using and keys
  4. Press COPY (central key)
  5. The name of the day to copy (source) is replaced by indication, and the day on which to copy (target) is fl ashing.
  6. Choose the target day using and keys
  7. Press to validate,
  8. Go back to point 6 for each of the other days to copy on.
    equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
19

Setting Date and Time

  1. Press MENU (left key) to enter the Programmation menu, symbol and indication are flashing

  2. Press (setting temperature key) to enter settings menu, symbol and indication are flashing
    equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
20

  3. Press to validate, the year is displayed and the indication is fl ashing
    equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
21

  4. Press to validate, the year is fl ashing

  5. Set the year using and keys

  6. Press to validate, the month is displayed and the indication is flashing

  7. Press to validate, the month is flashing

  8. Set the month using and keys

  9. Press to validate, the day is displayed and the indication is flashing
    equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
22

  10. Press to validate, the day is flashing

  11. Set the day using et keys

  12. Press to validate, the hour is displayed and the indication is flashing

  13. Press to validate, the hour is flashing

  14. Set the hour using and keys

  15. Press to validate, the minutes are dis- played and the indication is flashing
    equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
23

  16. Press to validate, the minutes are flasing

  17. Set the minutes using and keys

  18. Press to validate

Temperature override

In AUTO mode, it is possible to correct the setpoint temperature using the and keys.
This temporary setting will be canceled at the next scheduled time range.
Example: It is Saturday at 10 am, the set temperature is 18°C, I can rise to 19°C using the key, and it will automatically switch to 21°C at 12 pm.

Press AUTO (central key) to force a return to the programmed temperature without waiting for the next range.
Press “+ 1h ” (right key) to limit the override period to one hour.

Vacation mode

This function allows you to program a constant temperature for a chosen number of days, in order to reduce energy costs.

  1. Press MENU (left key) to enter the Programmation menu, symbol and indication is fl ashing

  2. Press twice, symbol and indication is flashing
    equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
24

  3. Press to validate, the indication is displayed and the number of days is flashing

  4. Set the number of days using and keys

  5. Press to validate, the indication is displayed and the temperature is flashing

  6. Set the desired temperature using et keys

  7. Press to validate, the remaining number of days will change every day at midnight

  8. To cancel, press MENU (left key), then press to validate

Keypad lock

  1. Keep pressing MENU (left key) and (right key) simultaneously for 5 seconds to lock the keypad. The symbol is displayed.
  2. Proceed in the same way to unlock.

equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
25

Optimum start

This Thermostat has optimization functions that aim to save energy while maintaining suitable comfort levels.
The thermostat learns how long it takes your home to reach a set temperature and then turns the heating on a bit earlier to achieve that temperature at the programmed time.
By default optimization is disabled, see instructions in installer mode on how to activate it.

The Thermostat displays during the optimization period if set.

Installer Mode

The thermostat is factory set to control a gas boiler.
Installer Mode allows you to modify these factory settings respecting the below values.

Applications| Cycles / hour| mini ON time| Settings to change
---|---|---|---
Gas boiler (<30 kW)| 6| 1 min| No change
Oil boiler – Heat pump
Pellet stove| 3| 4 min| Parameter 30T on 4
Parameter 2CR on 3

  1. Keep pressing MENU (left key) and (tempe- rature setting) simultaneously for 3 seconds to access installer mode.
  2. Choose parameter to change using and keys
  3. Press to change a parameter,
  4. Set the parameter using and keys
  5. Press to validate
  6. Press to exit installer mode
    equation TH40DP6 Digital Programmable Room-Temperature Thermostat - figure
26
Param. Description Values range
1LA Display language 1=EN, 2411_, 3=FRI 4=DE, 5=IT, 6=ES,

7=PT18=CZ, 9=HUJO=PLi1=R0112=SKI13=HR
2CR| Cycle Rate| 31619, 12
30T| Minimum boiler ON time| | 1
5 min
4LL| Lower temperature limit| 5….21°C
5UL| Upper temperature limit| 21….35°C
650| Ty| oe of| orogrammation| 1=7 days, 2=5+2 days
9LC| Fail Safe| 0=Disabled, 1= Enabled
10BL| Backlight| 0=Disabled, 1= Enabled
11CL| Clock format| 0=24h 1=12h
12DS| Daylight saving| 0=Disabled, 1= Enabled
13T0| Temperature offset| -3 +3°C
15SD| Reset schedule| 0, 1| Reset
16FS| Factory reset| 0, 1| (Reset)
170P| 0| timum start| 0=Disabled, 1= Enabled
19LK| Lock options| 1=Partial, 2=Total
Technical data

Type of Control| Independently mounted control for Surface mounting
Electrical protection| IP30 No protection against water ingress
CLASS II Product that does not incorporate protective earthing provision,
but a double insulation as provision against electric shock
Type of Batteries| 2 batteries AA (LRO6 )115 V (not supplied)
Temperature range| 5-35°C
Action| Micro-interrupt,| Type| 1.0
Rated current| Rated voltage : 24-230V–, 50-60Hz – Max rated current for Resistive load : 3A
Max rated current for Inductive load :1A
Environment| Pollution degree = 2 (standard household conditions without conductive dust)
Regulation class
,
(according 811/2013)| Class IV| Rated impulse voltage| 2500 V
Energy efficiency gain (contribution to seasonal space heating energy efficiency)| 2%
Class of Software| Class A| I Overvoltage Category according IEC/EN 60730-1| II
Supplier| ADEO Services -135 Rue Sadi Carnot, CS 00001, 59790 – RONCHIN – FRANCE

TROUBLESHOOTING

Operation issues are often due to minor causes; please go over the table below before contacting the After-Sales Service. This could save you time and spare you unnecessary  expenses.

Problem Causes, solutions
No Display Check batteries by opening cover.

Check that batteries are placed in the correct position.
Replace the batteries.
The symbol is displayed| The batteries are getting weak.. (less than 10% capacity)
The symbols and are flashing| Replace batteries immediately
The symbols and — are displayed| The sensor is faulty, contact your installerto repair or replace
the thermostat.

In case of persistent problem, please contact the after-sales service of your store.

Warranty
The warranty does not cover problems related to improper installation, incorrect wiring or improper use.

Processing waste of electronic and electric devices at life-cycle end.

This image indicates that this product must not be disposed of with unsorted home trash. A system for disposal and special processing of used electric and electronic devices, manda-tory to follow, has been implemented including the right to have vendors retrieve free-of-charge used appliances upon purchase of new appliances, as well as special collection of such waste by approved organisations. For more information on this, you can contact your store or your town hall. Proper disposal of used electric and electronic appliances ensures their adequate processing and recycling in order to avoid damage to the environment and public health as well as to preserve natural resources.

Made in United Kingdom
ADEO Services – 135 Rue Sadi Carnot
CS 00001 – 59790 RONCHIN – France

Documents / Resources

| equation TH40DP6 Digital Programmable Room-Temperature Thermostat [pdf] Instruction Manual
TH40DP6, Digital Programmable Room-Temperature Thermostat, TH40DP6 Digital Programmable Room-Temperature, Thermostat, Thermostat
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals