INTRODUCTION
The room thermostat turns the heating system on and off to obtain the desired
temperature (set temperature). It detects the air temperature and compares it
with the set temperature. If the room temperature is lower than the set
temperature, the thermostat turns on the boiler, and turns it off when the set
temperature is reached, and so on.
Energy efficiency is ensured by a self-learning TPI control algorithm, which
adapts to the environment and provides tight temperature regulation with
minimal energy consumption.
To obtain an optimum setting, set a low temperature (18°C for example) and
increase degree by degree each day to reach the temperature that suits you
(comfort temperature).
The thermostat does not affect the power of the boiler, so there is no need to
set a higher temperature to heat faster.
If the radiators have valves (manual or thermostatic) make sure that the
radiators located in the same room as the thermostat are open.
The thermostat is compatible with modulating boilers, but with a reduction in
performance. It is compatible with floor heating system is included in a full
system by a specialist (hot water control should be managed by another system)
INSTALLATION
The thermostat must be installed on a wall away from any source of heat (fi
replace, radiator, sun) and drafts (window, door), at a height of 1.2 m to 1.5
m.
It must be connected to the inputs for an “ON/OFF” remote thermostat (T1 and
T2) of a boiler, regardless of the polarity. The diagram on the label stuck in
the box corresponds to the particular case of a series connection to the
boiler supply. In this case, it is important to connect phase (L) to terminal
A of the thermostat.
The installation must be carried out by a person possessing the required
qualifi cations while respecting the national wiring standards in force.
Inserting batteries
- Push the cover of the battery compartment in the direction of the arrow in order to remove it.
- Insert 2 AA (LR06) 1,5V batteries in the compartment. Make sure you observe the right polarity (“+” and“-”).
- Place the cover of the battery compartment back.
Important!
- Do not let children play with batteries
- Do not ingest batteries
- Non-rechargeable batteries are not to be recharged;
- Different types of batteries are not to be mixed;
- New and used batteries are not to be mixed;
- Batteries are to be inserted with the correct polarity;
- Exhausted or leaking batteries are to be removed from the appliance and safely disposed of;
- If the appliance is to be stored unused for a long period, the batteries should be removed;
- The supply terminals are not to be short-circuited;
- The batteries must be removed from the appliance before it is scrapped.
USE
Displays
Controls and navigation
First start-up
When inserting the batteries for the first time, it is necessary to set the
user’s language, the date and time, and the type of programming.
|
---|---
-
Choose the language using the and keys
-
Press (Right key) to validate.
-
the indication is displayed and the year is flashing
-
Set the year using and keys
-
Press to validate.
-
Set the month using and keys.
-
Press to validate.
-
Set the day using and keys.
-
Press to validate.
-
Set the hour using and keys.
-
Press to validate.
-
Set the minutes using and keys.
-
Press to validate, the indication is displayed and the type of programming is flashing. Set the programming type using and keys The programming type “7d” allows to set different time ranges for each day of the week.
The programming type “5-2” proposes a setting for weekdays (from Monday to Friday) and another one for weekends (Saturday and Sunday). -
Press to validate.
Operating modes
Several operating modes are available:
- AUTO : The thermostat follows the pre-recorded internal programs for each day of the week. These programs defi ne which temperature to set for each of the 6 time ranges of the day. It is possible to customize these programs.
- MAN (Manual): The thermostat constantly monitors the set temperature using the and keys.
- OFF (Frost Protection Mode): The thermostat maintains a temperature above 5°C to protect against freezing.
Change Operating mode
- Press (right key) to put the thermostat in Frost Protection Mode, which is displayed.
- Press again to activate the thermostat, disappears.
- Press (central key) to switch between AUTO and MANUAL modes.
It is not possible to activate AUTO or MANUAL mode when the thermostat is in OFF mode.
AUTO mode programs
The AUTO mode allows 6 temperature level changes that can be programmed for
each day between 12:00 am and 11:50 p.m. Each temperature level can be set
between 5 ° C and 35°C by steps of 0.5°C. The default programs are
:
Customize programs
-
Press MENU (left key) to enter the Programmation menu , symbol and indication are flashing
-
Press (right key) to validate, the first day is displayed and its number is flashing.
-
Choose the day to change using and keys If the “5-2” programming type has been chosen when first startup, only “MO: FR” and “SA: SU” options can be changed.
-
Press to validate, the first time range is fl ashing, the trigger time and the set temperature are displayed.
-
Choose the first time range to change using the and keys
-
Press to validate, the trigger time is flashing
-
Set the time using the and keys
-
Press to validate, the temperature is flashing
-
Set the temperature using the and keys
-
Press to validate.
-
Go back to point 5 for each of the other time ranges
-
Go back to point 3 for each of the other days or copy the day (see below) At each time, it is possible to go back to the previous step by pressing (Left key)
Copying time ranges from one day to another
- Press MENU (left key) to enter the Programmation menu, symbol and indication are flashing
- Press (right key) to validate, the first day is displayed and its number is fl ashing.
- Choose the day to copy using and keys
- Press COPY (central key)
- The name of the day to copy (source) is replaced by indication, and the day on which to copy (target) is fl ashing.
- Choose the target day using and keys
- Press to validate,
- Go back to point 6 for each of the other days to copy on.
Setting Date and Time
-
Press MENU (left key) to enter the Programmation menu, symbol and indication are flashing
-
Press (setting temperature key) to enter settings menu, symbol and indication are flashing
-
Press to validate, the year is displayed and the indication is fl ashing
-
Press to validate, the year is fl ashing
-
Set the year using and keys
-
Press to validate, the month is displayed and the indication is flashing
-
Press to validate, the month is flashing
-
Set the month using and keys
-
Press to validate, the day is displayed and the indication is flashing
-
Press to validate, the day is flashing
-
Set the day using et keys
-
Press to validate, the hour is displayed and the indication is flashing
-
Press to validate, the hour is flashing
-
Set the hour using and keys
-
Press to validate, the minutes are dis- played and the indication is flashing
-
Press to validate, the minutes are flasing
-
Set the minutes using and keys
-
Press to validate
Temperature override
In AUTO mode, it is possible to correct the setpoint temperature using the and
keys.
This temporary setting will be canceled at the next scheduled time range.
Example: It is Saturday at 10 am, the set temperature is 18°C, I can rise to
19°C using the key, and it will automatically switch to 21°C at 12 pm.
Press AUTO (central key) to force a return to the programmed temperature
without waiting for the next range.
Press “+ 1h ” (right key) to limit the override period to one hour.
Vacation mode
This function allows you to program a constant temperature for a chosen number of days, in order to reduce energy costs.
-
Press MENU (left key) to enter the Programmation menu, symbol and indication is fl ashing
-
Press twice, symbol and indication is flashing
-
Press to validate, the indication is displayed and the number of days is flashing
-
Set the number of days using and keys
-
Press to validate, the indication is displayed and the temperature is flashing
-
Set the desired temperature using et keys
-
Press to validate, the remaining number of days will change every day at midnight
-
To cancel, press MENU (left key), then press to validate
Keypad lock
- Keep pressing MENU (left key) and (right key) simultaneously for 5 seconds to lock the keypad. The symbol is displayed.
- Proceed in the same way to unlock.
Optimum start
This Thermostat has optimization functions that aim to save energy while
maintaining suitable comfort levels.
The thermostat learns how long it takes your home to reach a set temperature
and then turns the heating on a bit earlier to achieve that temperature at the
programmed time.
By default optimization is disabled, see instructions in installer mode on how
to activate it.
The Thermostat displays during the optimization period if set.
Installer Mode
The thermostat is factory set to control a gas boiler.
Installer Mode allows you to modify these factory settings respecting the
below values.
Applications| Cycles / hour| mini ON time| Settings to
change
---|---|---|---
Gas boiler (<30 kW)| 6| 1 min| No change
Oil boiler – Heat pump
Pellet stove| 3| 4 min| Parameter 30T on 4
Parameter 2CR on 3
- Keep pressing MENU (left key) and (tempe- rature setting) simultaneously for 3 seconds to access installer mode.
- Choose parameter to change using and keys
- Press to change a parameter,
- Set the parameter using and keys
- Press to validate
- Press to exit installer mode
Param. | Description | Values range |
---|---|---|
1LA | Display language | 1=EN, 2411_, 3=FRI 4=DE, 5=IT, 6=ES, |
7=PT18=CZ, 9=HUJO=PLi1=R0112=SKI13=HR
2CR| Cycle Rate| 31619, 12
30T| Minimum boiler ON time| | 1
5 min
4LL| Lower temperature limit| 5….21°C
5UL| Upper temperature limit| 21….35°C
650| Ty| oe of| orogrammation| 1=7 days, 2=5+2 days
9LC| Fail Safe| 0=Disabled, 1= Enabled
10BL| Backlight| 0=Disabled, 1= Enabled
11CL| Clock format| 0=24h 1=12h
12DS| Daylight saving| 0=Disabled, 1= Enabled
13T0| Temperature offset| -3 +3°C
15SD| Reset schedule| 0, 1| Reset
16FS| Factory reset| 0, 1| (Reset)
170P| 0| timum start| 0=Disabled, 1= Enabled
19LK| Lock options| 1=Partial, 2=Total
Technical data
Type of Control| Independently mounted control for Surface mounting
Electrical protection| IP30 No protection against water ingress
CLASS II Product that does not incorporate protective earthing provision,
but a double insulation as provision against electric shock
Type of Batteries| 2 batteries AA (LRO6 )115 V (not supplied)
Temperature range| 5-35°C
Action| Micro-interrupt,| Type| 1.0
Rated current| Rated voltage : 24-230V–, 50-60Hz – Max rated current for
Resistive load : 3A
Max rated current for Inductive load :1A
Environment| Pollution degree = 2 (standard household conditions without
conductive dust)
Regulation class
,
(according 811/2013)| Class IV| Rated impulse voltage| 2500 V
Energy efficiency gain (contribution to seasonal space heating energy
efficiency)| 2%
Class of Software| Class A| I Overvoltage Category according IEC/EN 60730-1|
II
Supplier| ADEO Services -135 Rue Sadi Carnot, CS 00001, 59790 – RONCHIN –
FRANCE
TROUBLESHOOTING
Operation issues are often due to minor causes; please go over the table below before contacting the After-Sales Service. This could save you time and spare you unnecessary expenses.
Problem | Causes, solutions |
---|---|
No Display | Check batteries by opening cover. |
Check that batteries are placed in the correct position.
Replace the batteries.
The symbol is displayed| The batteries are getting weak.. (less than 10%
capacity)
The symbols and are flashing| Replace batteries immediately
The symbols and — are displayed| The sensor is faulty, contact your
installerto repair or replace
the thermostat.
In case of persistent problem, please contact the after-sales service of your store.
Warranty
The warranty does not cover problems related to improper installation,
incorrect wiring or improper use.
Processing waste of electronic and electric devices at life-cycle end.
This image indicates that this product must not be disposed of with unsorted home trash. A system for disposal and special processing of used electric and electronic devices, manda-tory to follow, has been implemented including the right to have vendors retrieve free-of-charge used appliances upon purchase of new appliances, as well as special collection of such waste by approved organisations. For more information on this, you can contact your store or your town hall. Proper disposal of used electric and electronic appliances ensures their adequate processing and recycling in order to avoid damage to the environment and public health as well as to preserve natural resources.
Made in United Kingdom
ADEO Services – 135 Rue Sadi Carnot
CS 00001 – 59790 RONCHIN – France
Documents / Resources
|
equation TH40DP6 Digital Programmable Room-Temperature
Thermostat
[pdf] Instruction Manual
TH40DP6, Digital Programmable Room-Temperature Thermostat, TH40DP6 Digital
Programmable Room-Temperature, Thermostat, Thermostat
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>