Filling the VF Nimbus (VF-4A-FOG)

  1. Unplug the unit from the wall outlet. Open the water tank lid and fill with water. Max capacity is 6-gallons. Use two EfferSan tablets per gallon of water. Let the tablets fully dissolve (4-5 minutes) before tuning on.
  2. Flip the lid back down, then plug the power cord into the outlet.
  3. Press the power button. The power light will be green or blue.
  4. When the disinfectant runs low, the machine will auto turn off. At that point, the water shortage light will be on (red light). Start at Step 1 to refill.

Part List

viruserv VF-4A-FOG VF Nimbus Four Atomizer Fogger - Part
List

DISPLAY PANEL

Operation

  1. Display: the display indicates the room temperature in Celsius. If no function button is pressed, the display will turn dark after 5-seconds.
  2. Mist Button: press the Mist Button to choose between levels 1~5. Level 5 is the highest power working mode. The default mist level is 5.
  3. Humidity Button: press the Humidity Button and it will increase 5%RH (relative humidity). If you want to set a target humidity, it has a range from 40%-90%RH. Continue to touch until max 90%. Cycle through if you go past your desired RH. When the %RH reaches your target humidity, the fogger will stop. The fan will stop after 10-seconds, along with the Anion function.
  4. Timer Button: the timer can be selected in 1-hour increments, from1-12 hours. Once you choose your setting, after 3-seconds, it will turn to timer mode. Once the duration is complete, the machine will auto turn off. Touch the Power Button to restart.
  5. Anion Button: the Anion function creates negative ions, which cause floating particulates (dust, dander, allergens, pathogens) in the air to cling together and drop to the floor. If the disinfectant runs low, the Anion function will auto turn off. Once the tank is refilled, the Anion function will work again.
  6. Auto/Sleep Button: touch sleep to start sleep mode, touch any button to wake up.

Disinfectant Shortage

If the disinfectant runs low, the fog will stop, and the fan will stop after 10-seconds. The water shortage signal will flash for 0.5 seconds, sound a beep 3-times, then turn off after 15-seconds.
The water level light will turn off as well.

Problem

viruserv VF-4A-FOG VF Nimbus Four Atomizer Fogger -
Problem

Documents / Resources

| viruserv VF-4A-FOG VF Nimbus Four Atomizer Fogger [pdf] User Manual
VF-4A-FOG, VF Nimbus Four Atomizer Fogger
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals