Tendcent TM8 Face Recognition and Temperature Terminal Instructions
- June 6, 2024
- Tendcent
Table of Contents
Tendcent
Tendcent TM8 Face Recognition and Temperature Terminal
8-inch ultra-thin Face Recognition Body Temperature Detection Terminal
Suitable for Brake machine, wall-mounted, desktop, floor-
mounted installation
Model:
Suitable for office areas, hotels, passage gates, office buildings, schools,
shopping malls,shops, communities, construction sites and other public
services and management projects where face access control is required.
Product Features
- Wide dynamic monocular living anti-counterfeiting, completely solving the deception of various photos on various uploads;
- Support LED intelligent fill light;
- Support serial port, Wiegand 26-bit, 34-bit output, and support output content configuration;
- Real-time body temperature monitoring, and body temperature tolerance range is accurate to 0.3 °, body temperature detection distance is 0.3-0.5 meters;
- Support the device to store thousands of people locally
- The cloud platform device supports the simultaneous storage of 50,000 face photos (less than 400KB), 1 million identification records (0.45KB), and 20,000 live capture photos;
- The LAN device supports simultaneous storage of 20,000 face photos (the photo is calculated based on 100KB) and 1 million recognition records (including the recent 10,000 live capture photos).
Instructions
- N face recognition, the face database supports 20,000 faces, and the top1 percentage of hits is 99.99%;
- The accuracy ratio of 1: 1 personal identification is over 99%;
- Fast recognition
- Face tracking and detection takes about 20ms;
- Face feature extraction takes about 200ms;
- The live detection of face identification takes 0.2ms;
- Feature identification takes 0.5ms (multiple recognition of 10,000 face database takes average);
- Support stranger detection, stranger level can be configured;
- Support live photo saving on face recognition or stranger detection;
- Support HTTP port connection;
- Support public network and local area network management
- Support screen display of content configuration
- Support identifying distance configuration
Environmental Requirements:
Conditions to be avoided during use:
- The sensor should be used in an indoor environment because it is greatly influenced by the environment when used outdoors
- Because of the characteristic of an infrared sensor, the accuracy of measurement will be seriously affected in the application environment, such as the sensor facing the window, air conditioner, radiator and other high-temperature objects
Product Specification Table
Product model | Category | Performance |
---|---|---|
camera | Resolution | 200W |
Types | RGB + IR | |
Aperture | 4.0mm | |
Focus | 0-2 米 0 to 2 meters | |
White balance | Auto | |
Screen | size | 8 IPS |
8-inch, full-view IPS LCD screen
| |
---|---|---
Resolution| 1280800 500cd 1280 800, brightness 500cd
Processor| CPU| 4 cores,RK3288
RAM| DDR3| 2GB
ISP| Image Processing| ISP Built-in dual-channel ISP
Local storage| Tf card| 8GB
Accessories| Fill light| Infrared, LED lights
Card reader module (Reserved)| IC/ID IC / ID card reader, ID card reader
and thermal imaging temperature
detection module
Network module| 2.4Gwifi、4G 网卡Support wired, 2.4Gwifi, 4G network card
Port| Audio| line out 1 Audio line out
USB 口 USB port| USB2.0 micro2 个
USB2.0 and 2micros
232
Serial port 232
| 2 RS232 ports, 1 WG input, and with WG output
Wiegand port| 2.5mmX2PIN
| Reset port| Lateral pore position, external buttons
---|---|---
OTG OTG port| 1 In Channel 1
Functions
| Offline locally use| 20 thousand local face database
Face Detection| Support simultaneous detection and tracking
of 5people
1: N face recognition| Support one in 10,000 error recognition with 99% pass
rate
1:1| Support optional card swiping module, ID card module which can realize 1:
1 face identification
Stranger detection| Support
Distance recognition adjustment| Support
Remote upgrade| Support
Device port| Including equipment management, access
control, personnel or photo management, record query,
etc.
General parameters| Protection level| For semi-outdoor or pure outdoor
use
| |
---|---|---
Power| DC12V
Operating temperature| -10℃-60℃
Working humidity| 10%-90%
Static electricity| 4K/8K
Battery radiation| Not exceeded
Power consumption| 5W MAX
Equipment weight| 1.6KG
About3.5 lbs
Equipment size| 373.713585mm
Modules| Functions| Introductions
---|---|---
Display interface| Boot interface| Neutral (customizable)
| Verification interface|
1. Including display of prompt ‘Please punch in’ , network signal (whether it is bound/connected), time, date, weekday;
2. Pop-up prompts for abnormal network connection, notification display, ID card information, and prompts for successful or failed verification , which can be customized
3. Including the version number, the number of people, and the number of pictures in database.
---|---|---
Menu interface| Menu style and human-computer interaction, how to enter
other modules, management, etc.
User Management
| User added| Add people to local apps
User delete| Delete people on local apps
Equipment management
| Unlocking rules| Door opening time after verification
Wiegand / RS23| Wiegand format 26/34, RS232
language settings| Simplified Chinese
Network settings| Wired, Wifi
Time settings| Time, date, time zone, setting (manual setting or server
synchronization)
| |
---|---|---
Voice settings| 0-10 (0 is silent, the default is 5)
Brightness settings| 1-10 (default is 5)
About this machine
| Date of
manufacture
| The equipment time
Serial number| Devise serial number
Manufacturer| Manufacturer name
Machine type| Device model
Others| Other functions| Customizable
Dimensions
- Body temperature of scanning face
- Standard body temperature
The schematic diagram of the gate is shown in t he figure below.
Note: If the cable interface is different from the illustration, see the
cable supplement on the next page (subject to the actual product and wiring
diagram)
Instructions for appearance
-
According to the requirements of the installation site, a space of 35mm in diameter is generally opened in the middle or front of the gate , as shown in the figure, is the recommended opening position.
Note: The position of the opening should be based on the actual application and the type of gate 35mm is only a reference. -
Unscrew the nut at the bottom of the gate , pass the cable through the nut, and remove the nut, as shown in the figure.
Note: Do not connect the network cable, power cable, etc. At this time to avoid installation trouble -
Under the gate , pass the cable and cable interface through the washer and nut in sequence, and tighten the nut to the thread , as shown in the figure.
-
Connect the power and network cable, and the screen will start
-
Hold the post with both hands and turn it gently to adjust the angle of the gate , as shown in the figure. According to the recognition interface, adjust the gate to the proper recognition angle
For Desktop
- The nut needs to be removed, the tail wire is passed through the stainless steel bracket and the nut in sequence, and the angle is tightly tightened; it is suitable for program debugging.
- Place the desktop on the desktop, and place the device on the two “L” card positions above the bracket and adjust the angle; It is suitable for the front desk visitors.
For wall mounted
-
Rotary type : Firstly, put the white 86 switchback box on the wall at 1400mm and the specific height should depend on the actual use.And then mark the four corners of the back box with a pen, drill four holes with an impact drill, place the rubber plug in the hole, fix the back box with screws, and then do the cable. This method is installed for surface If concealed installation is required, draw a hole in the four sides of the size of the back box with an impact drill. Cement inserted inside should be estimated . After the cement is completely dry, fix the device to the back box with screws, as shown in the figure.
If there is any mistake with hand measure, subject to the actual product.
Note: Before tightening the screws, please ensure that all the tail wires are not crushed by the screws, causing a short circuit. -
Wall hanging type Firstly,r emove the stainless steel wall hangings from the device . And then put the stainless steel plate on the wall at an appropriate height, drill four holes with an impact drill, place the rubber plug in the hole, fix the stainless steel plate to the wall with tapping screws.( If the tail wire comes out of the back of the box, it is n ecessary to make a hole in the wall to facilitate the wiring. If the tail wire comes out from the bottom, it only needs to be fixed and routed with a large white plastic trunking.) As shown in the figure.
Wires outlet diagram of Wall-mounted
Cable wiring diagram, as follows
- Switch signal
- Wiegand input
- Wiegand output
- signal 232
8-inch face recognition tail wire description
- seven gate tail wires
- USB2.0 interface
- 12V power input
- Reset / Reset button
- Switch signal
- Wiegand input
- signal 232
- RJ45 wired network port
5Wall-mounted tail wires
- USB2.0 interface
- 12V power input
- Switch signal
- Wiegand output
- RJ45 wired network port
Product Name: Face Recognition & Temperature
Terminal Model: T-M8
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>