IP44 DE CUT ONE Outdoor Wall Light Instruction Manual

June 6, 2024
IP44 DE

IP44 DE CUT ONE Outdoor Wall Light Instruction Manual

cut one instructions for use

  1. Push main cable through cable entry part of the wall bracket and ensure tight seal.
  2. Attach wall bracket. Pay attention of position „top“. Use the washer gaskets with rubberized face against to the wall bracket. Seal unused mounting holes.
  3. Establish ground connection and connect power lines.
  4. Hook light housing into notch of the wall bracket. Press luminaire to the wall bracket and tight set screws flush and evenly. Avoid pinched cables.

light technology:

230V Power LED / 2700K system performance: 8 W/498 lm EEC

technical information:

operating voltage 230V / 50Hz

protection class
safety class 1
Luminaire is suitable for mounting on normal inflammable surfaces.
conformity mark

maintenance:

Disconnect the electrical installation.
This luminaire contains built-in LED lamps. The LED lamps can be replaced by IP44.de in case of a failure of the LED. In this case, please get in touch with your retailer.

dimming:

The luminaire can be dimmed with an approved leading- or trailing edge dimmer. Please contact IP44.de service center for a list of approved dimmers.

care:

Regularly clean luminaire from dirt and deposits. Do not use a high pressure cleaner for cleaning. Please note care instructions at www.IP44.de.

safety:

We point out that the electric connection of light fixtures has to be done by a certified installer. We assume no accountability for damages which are a result of non-appropriate
mounting or application of the luminaire. Modifications on the luminaire will result in loss of warranty.

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals