4RF Aprisa SR+ Data Driven Protected Station User Guide
- June 6, 2024
- 4RF
Table of Contents
- Contents
- Check the box contents
- Install the Aprisa SR+ Data-Driven Protected Station and connect the
- Connect the antenna and apply power to the Aprisa SR+ Data-Driven
- Set up the Aprisa SR+ Data-Driven Protected Station
- Monitor the Aprisa SR+ Data-Driven Protected Station signal strength
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
User Guide
Aprisa SR+ Data Driven Protected Station
Contents
Follow these steps to set up your Aprisa SR+ Data-Driven Protected Station:
- Check the box contents
- Install the Aprisa SR+ Data-Driven Protected Station and connect the protection earth
- Connect the antenna and apply power to the Aprisa SR+ Data-Driven Protected Station
- Connect to the Aprisa SR+ Data-Driven Protected Station
- Set up the Aprisa SR+ Data-Driven Protected Station
- Monitor the Aprisa SR+ Data-Driven Protected Station signal strength
Check the box contents
The Aprisa SR+ Data-Driven Protected Station is shipped to you in a containing
the following:
Aprisa SR+ Data-Driven Protection Station
- Two Aprisa SR+ radios mounted on a 19” rack mount shelf.
- Two duplexers mounted on a 19” rack mount shelf with fitted SMA to TNC cables for connection to the radios
- Two 2 pin female power connectors
- One 4 pin female remote control connector
Install the Aprisa SR+ Data-Driven Protected Station and connect the
protection earth
The Aprisa SR+ Data-Driven Protected Station is designed to mount in a standard 19” rack.
The Aprisa SR+ Data-Driven Protected Station has an earth connection point on
the left top of each radio. Use the supplied M4 screw to earth the enclosure
to protect earth.
The antenna feeder cable should use grounding kits for lightning protection as
specified or supplied by the coaxial cable manufacturer to properly ground or
bond the cable outer.
Connect the antenna and apply power to the Aprisa SR+ Data-Driven
Protected Station
Connect the antennas to the duplexer antenna ports (N-type female connector).
If the antennas are not available, terminate the antenna ports with N-type
male 50-ohm terminators (5 Watts min).
The Aprisa SR+ Data-Driven Protected Station is operated from a DC source of
voltage between +10 VDC and +30 VDC (negative earth) and consumes up to 35
Watts. Two power connectors (Phoenix Contact 2 pin female) are supplied fitted
to the radios. Wire your power source to the two power connectors (- / +) and
plug the connectors into the radios. The connector screws can be fastened to
secure the connectors.
Note: The radio fuses will blow if the connected power supply is over- voltage, or the polarity is reversed. Two spare fuses are located inside the enclosure (see the ‘Spare Fuses’ section of the Aprisa SR+ User Manual). Turn your power source on. All the LEDs on both radios will flash orange for one second and then change to:
- Active radio – the OK, MODE, and AUX LEDs will light green and the TX and RX LEDs will light green (steady or flashing).
- Standby radio – the OK, TX, RX, and AUX LEDs will light green and the MODE LED will flash green.
If the IP addresses of radios in the Data-Driven Protected Station are unknown
for some reason, they can be shown or changed via the Command Line Interface
(CLI) on the radios MGMT USB ports. USB to UART Bridge VCP Drivers are
required to connect the radio USB port to your PC. You can download and
install the relevant driver from
https://www.silabs.com/products/development-tools/software/usb-to-uart-
bridge-vcp-drivers. Set the PC serial port to 38,400 baud, 8 data bits, no
parity, and 1 stop bit, with no hardware flow control.
- Connect your PC USB port to the primary Aprisa SR+ (A) MGMT USB port (see the Aprisa SR+ User Manual CLI section)
- Login to the radio with the default login ‘admin’ and password ‘admin’.
- At the command prompt,>> type ‘cd APRISASR-MIB-4RF’ and enter
- At the command prompt >> type ‘ls Terminal’ and enter to show the existing IP address
- At the command prompt >> type ‘set termEthController1IpAddress xxx.xxx.xxx.xxx’ and enter to change the IP address.
The Data-Driven Protected Station is configured in the 4RF factory as a Data- Driven Protected Station. If for some reason it is not set up as a
Data-Driven Protected Station, please see ‘Creating a Data-Driven Protected Station’ in the Aprisa SR+ User Manual.
Set up the Aprisa SR+ Data-Driven Protected Station
Login using the IP address of either the primary or secondary radio (do not
use the PVIP address for login). All parameters will be automatically
synchronized on both radios.
Set the Ethernet Operating Mode and the Compliance Mode required. The
Protection Type should already be set to ‘Serial Data-Driven Switching’.
Set the unique radio Network ID to be the same in your entire network.
Set the Aprisa SR+ TX Frequency, RX Frequency, TX Power, and Channel Size to comply with your site license. Set the Antenna Port Configuration required.
You can now configure the remaining Data-Driven Protected Station and network
parameters and settings.
For more information, please refer to the Aprisa SR+ User Manual available
from the 4RF website https://www.4rf.com/secure (login required).
Reboot both Primary and Secondary radios.
The Aprisa SR+ Data-Driven Protected Station is ready to operate.
Monitor the Aprisa SR+ Data-Driven Protected Station signal strength
When the network is installed, the radio signal strength can be monitored on
remote stations by setting the radio to Test Mode. To enter Test Mode, press
and hold the TEST button on the front panel until all the LEDs flash green
(about 3 – 5 seconds). In Test Mode, the LED Display panel presents a real-
time visual display of the RSSI. This can be used to adjust the antenna for
optimum signal strength.
Note: The response time is variable and can be up to 5 seconds. To exit Test
Mode, press and hold the TEST button until all the LEDs flash red (about 3 –
5seconds).
If the network is operating correctly, all the LEDs OK, MODE, AUX, TX, and RX
LEDs will be light green.
Aprisa SR+ Quick Start Guide – Data-Driven Protected Station 1.1.0 © 2021 4RF Limited. All rights reserved. This document is protected by copyright belonging to 4RF Limited and may not be reproduced or republished in whole or part in any form without the prior written permission of 4RF Limited. While every precaution has been taken in the preparation of this literature, 4RF Limited assumes no liability or errors and omissions, or from any damages resulting from use of this information. The contents and any product specifications within it are subject to revision due to ongoing product improvements and may change without notice. Aprisa and the 4RF logo are trademarks of 4RF Limited. All other marks are the property of their respective owners.