- Intended use
- Air10 oximeter adapter
- S9 oximeter adapter
- AirSense 10 / AirCurve 10 / Lumis S9
- Associated accessories
- Save the packaging
- Setup
- Removing and returning the oximeter adapter and SD card
- Cleaning and maintenance
- Troubleshooting
- Technical specifications
- Symbols
- Limited warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
37302 Air 10 Oximetry Module
User Guide
Thank you for choosing a ResMed oximeter adapter.
Intended use
The oximeter adapter connects a NONIN Xpod™oximeter to your device. Oximetry
data (oxygen saturation and pulse rate) is recorded on the SD card inserted
into the device.
The Air10 oximeter adapter shown in illustration A is compatible with
AirSense™ 10 / AirCurve™ 10 / Lumis™ devices. The oximeter adapter shown in
illustration B is compatible with S9 devices.
The oximeter adapter is intended for home and hospital use.
Read the entire guide before using the oximeter adapter.
Air10 oximeter adapter
Refer to illustration A:
- Adapter connector
- Release button
- Oximeter port.
S9 oximeter adapter
Refer to illustration B:
- Oximeter port
- Release buttons
- Adapter clip
- Adapter connector.
AirSense 10 / AirCurve 10 / Lumis S9
Refer to illustration C:
- SD Card cover
- Air filter cover
- Adapter cover
- Adapter port.
Refer to illustration D:
- DC power inlet
- Adapter clip socket
- Adapter port
- SD card slot
- Alarm (Bilevel alarmed devices only).
Associated accessories
- Xposed oximeter
- Xposed fixation clip
- Finger pulse sensor
- Oximetry accessories pack (including Xpod oximeter, Xpod fixation clip, and 3M oximeter soft sensor reusable).
Note: The compatible finger pulse oximeters are calibrated for the display of functional oxygen saturation.
Save the packaging
Keep all the packaging the oximeter adapter came in. You will need to return the oximeter adapter, this User Guide, and the SD card to your care provider.
Setup
Refer to illustration E or F:
-
Unplug your device from the power outlet.
-
Make sure an SD card is inserted into the SD card slot on your device.
-
Connect the oximeter adapter to your device.
-
Align the Xpod oximeter connector with the oximeter adapter port and connect them.
Not pictured: -
Connect the Xpod oximeter to the finger pulse sensor.
For instructions refer to the User Guide supplied with the finger pulse sensor. -
Connect the finger pulse sensor to your finger.
-
Plug your device back into the power outlet.
The AirSense 10 / AirCurve 10 / Lumis device will briefly display the oximeter software code, eg, SX123-4567.
The S9 device will briefly display Oximeter enabled.
You are now ready to start therapy. For more information, refer to your device User Guide.
Removing and returning the oximeter adapter and SD card
- Remove the sensor from your finger.
- Unplug your device from the power outlet.
- Press the release button/s on the side of the oximeter adapter and pull gently to remove it from the device.
- Pull the Xpod oximeter out of the oximeter port on the oximeter adapter.
- Remove the finger sensor cable from the Xposed oximeter.
- Open the SD card cover and push in the SD card to release it.
- Place the SD card in the protective folder and send it back to your care provider together with the oximeter adapter and this User Guide.
Cleaning and maintenance
If you need to, wipe the outside of the oximeter adapter with a clean, dry
cloth.
For instructions on how to clean the oximeter and its sensor, refer to the
User Guide supplied with those accessories.
Troubleshooting
If you have any problems, refer to the following troubleshooting topics. If
you are not able to fix the problem, contact your care provider or refer to
www.resmed.com.
Do not try to open the oximeter adapter.
Problem/possible cause | Solution |
---|
AirSense 10 / AirCurve 10 / Lumis: Check your finger sensor or press OK to
continue without oximetry S9: Check the oxi sensor or press the dial to
accept no oximetry data logging
The finger pulse sensor is not attached to your finger| Make sure the finger
pulse sensor is properly attached according to the instructions supplied with
that accessory.
The sensor cable is not connected to the Xpod oximeter at the start of
therapy.| Disconnect and reconnect the Xpod oximeter connector and sensor
cable according to the instructions supplied with these accessories.
AirSense 10 / AirCurve 10 / Lumis: Check oximeter connection or press OK to
continue without oximetry S9: Connect the oxi sensor or press the dial to
accept no oximetry data logging
The oximeter adapter is not connected properly or data is not transmitting
correctly.| Remove your oximeter adapter from the device according to the
instructions. Reattach your oximeter adapter and plug your device back into
the power outlet.
S9: Insert your SD Card or press dial to accept no oximetry data logging
The device cannot detect an SD card and no oximetry data can be logged or
stored.| Make sure that an SD card is correctly inserted in the SD card slot
of your device.
Note: If you need help or to report an unexpected issue, contact a ResMed representative, ResMed Technical services, or seewww.resmed.com.
Technical specifications
Operating temperature | +41°F to +95°F (+5°C to +35°C) |
---|---|
Operating humidity | 10 to 95% non-condensing |
Operating altitude | Refer to your device User Guide for details. |
Storage and transport temperature | -4°F to 140°F (-20°C to +60°C) |
Storage and transport humidity
Air10 oximeter adapter
S9 oximeter adapter| 5 to 95% non-condensing
10 to 95% non-condensing
Design life
Air10 oximeter adapter
S9 oximeter adapter| 1825 connections
1825 connections
Weight
Air10 oximeter adapter
S9 oximeter adapter| 0.95 oz (27 g)
0.77 oz (22.1 g)
Oximeter compatibility
Air10 oximeter adapter
S9 oximeter adapter| XPod 3012, XPod 3012LP
Xpod 3012
Electromagnetic compatibility| Refer to your device User Guide for details.
Note: The manufacturer reserves the right to change these specifications without notice.
Symbols
The following symbols may appear on the oximeter adapter or packaging:
Caution/Warning. Read instructions before use. Manufacturer.
European Authorized Representative. Batch code Catalog number. Serial number.
IP21 Protection against insertion of fingers and against vertically
dripping water. I P22 Protected against finger-sized objects and against
dripping water when tilted up to 15 degrees from specified orientation.
Humidity limitation. Temperature limitation. China pollution control logo.
Canadian Standards Association. Type BF equipment.
Prescription-only (In the US, Federal law restricts these devices to sale by
or on the order of a physician). Atmospheric pressure limitation.
Importer. Medical device.
See the symbols glossary at ResMed.com/symbols.
Notes:
- IP21 rating applies only to the S9 oximeter adapter.
- IP22 rating applies only to the Air10 oximeter adapter.
Environmental information
This device should be disposed of separately, not as unsorted municipal waste.
To dispose of your device, you should use the appropriate collection, reuse,
and recycling systems available in your region. The use of this collection,
reuse, and recycling system are designed to reduce pressure on natural
resources and prevent hazardous substances from damaging the environment.
If you need information on these disposal systems, please contact your local
waste administration. The crossed-bin symbol invites you to use these disposal
systems.
If you require information on the collection and disposal of your ResMed
device please contact your ResMed office, local distributor, or go to
www.resmed.com/environment.
WARNING
- Do not open or modify the oximeter adapter. The oximeter adapter is not designed to be serviced. There are no serviceable parts inside.
- Only use compatible NONIN™ finger pulse oximeters*.
- The finger pulse oximeter and cable needs to be verified for compatibility with AirSense 10 / AirCurve 10 / Lumis devices, otherwise, patient injury can result.
- Finger pulse oximeters must not be used with excessive pressure for prolonged periods as this can cause patient pressure injury.
- The reported values from the finger pulse oximeter are not appropriate to be used for diagnostic purposes and it shall not be used for vital sign monitoring.
*For part numbers of compatible oximeter accessories, refer to www.resmed.com or contact your care provider. For information on how to use these accessories, refer to the user guide that comes with these accessories.
CAUTION
- In the US, Federal law restricts this device to sale by or on the order of a physician.
- Only use the oximeter adapter as specified in this guide.
- S9 oximeter adapters are specifically designed for use with ResMed S9 devices.
- Air10 oximeter adapters are specifically designed for use with ResMed AirSense 10 / AirCurve 10 / Lumis devices.
- Do not use liquids to clean any part of the oximeter adapter.
- Factors that may degrade pulse oximeter performance or affect the accuracy of the measurement include the following: excessive ambient light, excessive motion, electromagnetic interference, blood flow restrictors (arterial catheters, blood pressure cuffs, infusing lines, etc.), moisture in the sensor, improperly applied sensor, incorrect sensor type, poor pulse quality, venous pulsations, anaemia or low haemoglobin concentrations, cardio green or other intravascular dyes, carboxyhaemoglobin, methaemoglobin, dysfunctional haemoglobin, artificial nails or fingernail polish, or a sensor not at heart level.
Note: Any serious incident that has occurred in relation to this device should be reported to ResMed and the competent authority in your country.
Limited warranty
Refer to your device User Guide.
ResMed Pty Ltd
1 Elizabeth Macarthur Drive
Bella Vista NSW 2153 Australia
See ResMed.com for other ResMed locations worldwide. Air10, AirCurve, AirSense, Lumis, ResScan and S9 are trademarks and/or registered trademarks of the ResMed family of companies. For patent and other intellectual property information, see ResMed.com/ip. Nonin and XPod are trademarks of Nonin Medical and registered in U.S. Patent and Trademark Office. © 2022 ResMed. 3781043/1 2022-02
References
- Sleep apnea and COPD - learn about symptoms and treatment | ResMed
- Environmental policy - ResMed
- Legal disclaimers and intellectual property - ResMed
- ResMed.com/symbols
- Sleep apnea and COPD - learn about symptoms and treatment | ResMed
- Environmental policy - ResMed
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>