ENVION TA550 Air Purifier User Manual

June 12, 2024
ENVION

ENVION logo

ENVION TA550 Air Purifier

ENVION TA550 Air Purifier

Product Information

Introduction

The TA550 is an ionic air purifier designed to clean and ionize the air in your space. It features a collection blade unit, control panel, and various settings for air purification.

Thank you for purchasing the Ionic Pro® Turbo and congratulations on taking this important step in im-proving the quality of air in your home, office and other environments. Customer satisfaction is our number one goal. Your Ionic Pro® Turbo is a premium air purifying appliance which comes with a limited one-year warranty.
Enjoy your Ionic Pro® Turbo and visit our website for more exciting quality products and upgrades. envion.com

Product Benefits

  • Cleans and ionizes the air
  • Helps remove dust, pollen, and smoke particles
  • Silent operation with no fans
  • Compact and portable design

Important Warnings

  • Do not touch the metal collection blades as they may contain a static charge

COLLECTION BLADES
Please look at the “Main Parts” diagram and locate the part labeled “A”.
These are the collection blades and are a vital part of this amazing ionic air purifying system. The collection blades are where pollutants, allergens, irritants and odors are trapped when the Ionic Pro® Turbo is in proper working condition and in use.
The metal collection blades may contain a static charge. Do not touch the metal collec-tion blades, even when you take the collection bla-de unit out for cleaning.

Main Parts

ENVION TA550 Air Purifier fig-1

  • A – Collection Blades
  • B – Open Button
  • C – Control Panel
  • D – Outer Housing
  • E – Main Door
  • F – Power Cord
  • G – Base
  • H – Flip up the carrying handle

Technical Data

  • Type designation: TA550
  • Power consumption: 12 W
  • Power supply voltage: 120V ~ 60Hz
  • Air-cleaning output: 21 Dust, 44 Pollen, 20 Smoke CADR cfm
  • Operation noise level: Silent / No Fans
  • Filter type: Collection Blades / Ionizer
  • Dimensions: 9.5 x 7.3 x 27.8 in / 24.1 x 18.6 x 70.5 cm
  • Weight: 7.9 lbs / 3.6 kg

Product Usage Instructions

Getting Ready

  • Place the TA550 on a stable surface in the desired location.
  • Ensure the power cord is accessible and plugged into a power outlet.

ENVION TA550 Air Purifier fig-2

  1. ON/OFF Button
    • a. LOW output indication light (L)
    • b. MEDIUM output indication light (M)
    • c. HIGH output indication light (H)
    • d. CLEAN indication light ( )
  2. CLEAN wire cleaning mechanism
  3. OPEN main door button
  4. CLEAN indication light
  5. CARRYING HANDLE flip up for convenient carrying

Controls / Settings

The control panel of the TA550 features the following buttons and indicators:

  • ON/OFF Button: Turns the unit on and off.
  • LOW/MED/HIGH output indication lights: Indicates the current air purification setting.
  • CLEAN indication light: Indicates the need for cleaning.

Selecting Settings

  • Press the ON/OFF button to activate the ionic air purifier.
  • Press the ON/OFF button again to select the MEDIUM (MED) output setting.
  • Press the ON/OFF button once more to select the LOW output setting.
  • Press the ON/OFF button a fourth time to turn off the unit.
  • The indicator LEDs will light up to indicate the current setting (LOW, MED, HI).

CLEAN LIGHT
The red CLEAN light will turn on and the unit will shut down if cleaning is overdue or AC input is un-stable. The Ionic Pro® Turbo ionic air purifier’s coll-ection blades must be cleaned after every month of use and the internal ionizing wires must be cleaned at the same time. (See “Cleaning & Maintenance” for full directions.) Once the collection blades are properly cleaned, normal operation should resume.

Cleaning & Maintenance

With very little effort, the Ionic Pro® Turbo ionic air purifier delivers cleaner, fresher, healthier air to your indoor environment. Keep your Ionic Pro® Turbo ionic air purifier functioning properly by cleaning the collection blades after every month of use as recommended. The internal ionizing wires are an important part of the Ionic Pro® Turbo ionic air purifying system and need to be cleaned at the same time or whenever you hear excessive noise. (See “Cleaning internal ionizing wires” and “About deep cleaning” sections.)
More frequent cleaning may be required if your Ionic Pro® Turbo ionic air purifier is new or if you place it in a different location. Exposing your Ionic Pro® Turbo ionic air purifier to candle/oil lamp/fireplace soot and smoke is not recom-mended and will require the collection bla-des to be cleaned after every exposure. (See “Important warnings”.)

To clean the collection blades:

  1. Turn off and unplug the air purifier.
  2. Allow the unit to rest for a minute.
  3. Pull upward on the release latch of the collection blade unit and remove it from the main door.
  4. Discharge residual electricity by touching the blades to an electrical ground, such as a water pipe or metal faucet.
  5. Wipe away trapped particles on the blades using a slightly damp sponge or cloth.

To clean dust inside the door of the air purifier:

  1. Open the door and remove the collection blades.
  2. Use the soft brush hose attachment of a vacuum cleaner to gently remove the dust. Do not use liquids for cleaning.

CLEANING INTERNAL IONIZING WIRES
There is an internal wire cleaner that cleans the in-ternal ionizing wires by sliding up and down to scra-pe off particle residue.

  1. Gently pull the lever up and down several times.
  2. The internal ionizing wires need to be cleaned after every four weeks of use.

ABOUT DEEP CLEANING
Noisy functioning (audible loud buzzing sound) is a sign that your Ionic Pro® Turbo ionic air purifier is overdue for a complete clean-up of the collection blades and the internal ionizing wires.
The internal ionizing wires must be kept clean to en-resilient and normal operation.

DEEP CLEAN

  1. First, turn OFF and unplug your Ionic Pro® Turbo ionic air purifier.
  2. Let it rest for a minute before sliding out the collection blades as described in the “To Clean the Collection Blades” section of this manual.
  3. Use a cloth and warm, sudsy water to wipe away dirt particles on the blades’ surfaces and edges.
  4. Rinse and let the blades dry thoroughly for 24 hours before re-inserting them into your Ionic Pro® Turbo ionic air purifier. If desired, you can purchase a second set of collection blades to use while the original blades are drying to allow for virtually uninterrupted air purification.
  5. Clean the ionizing wires as described in the “To clean the Ionizing Wires” section of this manual.

TROUBLESHOOTING

OZONE AND YOUR HEALTH
After you activate your Ionic Pro® Turbo ionic air purifier, you may notice a new clean scent.

TROUBLE REASON TROUBLE SHOOTING
Indication/Setting light does not turn on. Machine is unplugged. Check if

plug is loose.
ON/OFF button has not been pressed.| Press the ON/OFF button.
Main door not closed.| Close door.
Red CLEAN light is on or the unit shuts down.| Too much dust has accumulated.| Turn off, unplug & lift the lever to the wire cleaning mechanism to clean the ionizing wires.
AC input unstable or overloaded.| Turn off, allow unit to rest a while to return to normal.
Moisture on collection blades.| Temperature & moisture level and then turn on again.
Excessive noise generated.| Collection blades are not installed properly.| Remove & replace collection blades & press “On” button.
Too much dust has accumulated.| Clean and dry blades and ionizing wires thoroughly.*
Internal parts are wet.| Keep the machine dry.

MORE THINGS YOU SHOULD KNOW

IMPORTANT INFORMATION FOR YOUR HEALTH
The Ionic Pro® Turbo ionic air purifying system utilizes an ionizing process that results in very low ozone emission.
Individuals with a history of respiratory disease, asthma, heart disease, lung disease, breathing problems or concerns about ozone should ask their doctor whether the concentrations of ozone gene-rated by this or other commercial ionic air purifiers are appropriate for their specific health needs.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals