Z-WAVE PAN30 Wall Switch User Manual

June 6, 2024
Z-Wave

Z-WAVE PAN30 Wall Switch

Introduction

This in-wall dual relay switch module is a transceiver which is a Z-Wave Plus™ enabled device and is fully compatible with any Z-Wave™ enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration.
There are many kind of application by using the module to switch AC power On and Off, one main application is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light.
This in-wall switch module is able to detect Instant power wattage and overload current (7.5A with resistive load) of connected light or appliances. When detect­ing overload state, the Module will be disabled and its On/Off button will be lock­out of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status.
This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Safety Precautions and Installation

  • Avoid installing the unit in storming or raining weather.
  • Be sure to isolate or switch off power source before installing or maintenance.
  • Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse.

IMPORTANT

  • Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper installation.
  •  Check your local codes as they apply to your situation. If the house wiring is of aluminum, consult with an electrician about proper wiring methods.

Before proceeding with the installation, TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK.

Specification

Operating Voltage 100-240VAC 50Hz-60Hz
Maximum Load 6.5A x 2 Channel (@230Vac/120Vac) (Resistive load)
Range Minimum 40m indoor 100m outdoor line of sight
Operating Temperature 0°C ~ 40°C
Humidity Up to 85% max.
Storage Temperature -20°C to 60°C
Location Indoor use only
Frequency Range 868.40MHz; 869.85MHz (EU)

908.40MHz; 916.00MHz (USA/Canada)

920.90 MHz, 921.70 MHz, 923.10 MHz (Taiwan)

RF Power| +10dBm (Peak), -10dBm (Average)
OTA| Support
FCC ID| RHHPAN30
Dimensions| 47.5 x 39 x16 mm
Wire| 0.75mm² , 18AWG

Specifications are subject to change and improvement without notice.

Troubleshooting

Symptom Cause of Failure Recommendation
The Switch not working and LED off 1.  The Switch is not connect to the Main

power

2.  The Switch break down

| 1.  Check power connections

2. Don’t open up the Switch and send it for repair.

The Switch LED

illuminating, but cannot

| Check if the load connect into

the Switch has its own

| Set the ON/OFF switch of the

load attached to ON

control the ON/OFF

Switch of the load attached

| ON/OFF switch|
---|---|---
The Switch LED illuminating, but the Detector cannot control

the Switch

| 1.  Not carry out association

2. Same frequency interference

| 1. Carry out association

2. Wait for a while to re-try

LED keep flashing, but cannot control| Overload occurs| Remove the load attached or check max. load cannot exceed

7.5A(Resistive load)

Installation Steps

  1.  Connect PAN30 to AC N and L.
  2. Connect Load1 and Load2 to NO1 and NO2.
  3.  Connect external Switch to S1 and S2.

For Instruction to http:// www.philio-tech.com

Z-WAVE-PAN30-Wall-Switch-fig3

DANGER

Danger of electrocution!

All works on the device may be performed only by a qualified and licensed electrician. Observe national regulations.
Any works introducing changes into the configuration must be always performed with disconnected voltage.

Choosing a Suitable Location

  1.  Do not locate the Module facing direct sunlight, humid or dusty place.
  2. The suitable ambient temperature for the Module is 0°C~40°C.
  3. Do not locate the Module where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.
  4. After putting it into use, the body of Module will become a little bit hot of which phenomenon is normal.

Adding to Z-WaveTM Network

In the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carry out inclusion, exclusion, reset. When first power is applied, its LED flashes on and off alternately and repeatedly at 2 second intervals. It implies that it has not been assigned a node ID.
The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/reset devices

Function Description Annotation
No node ID The Z-Wave Controller does not allocate a

node ID to the Switch.

| LED 2-second on, 2-

second off

Add (Inclusion)| 1.   Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.

2.   Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.

| One press one flash LED

** To support handling of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up.

SmartStart| 1. To initiate the SmartSart process, please type in the first five digits of DSK string or scan the QR code. The QR Code can be found on PAN30 or in the box. Ex:

DSK: 18112-24021-58001-62259-

57092- 27453-08187-47408

2. PAN30 is supported with SmartStart, it can be added to Z-Wave™ network by scanning the Z-Wave™ QR code on the product.

3. Without further actions, PAN30 will be automatically included in a certified Z- Wave™ Controller with SmartStart inclusion

ability in 10 minutes after it turned on.

|
---|---|---
Remove (Exclusion)| 1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the

controller manufacturer.

| One press one flash LED

** To support handling of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up.

2. Pressing INCLUDE_BUTTON

three times within 2 seconds will enter exclusion mode.

3. Node ID has been excluded.| LED 2s On, 2s Off (No

node ID)

Reset| 1.      Pressing INCLUDE_BUTTON three times within 2 seconds will

enter inclusion mode.

| Use this procedure only in the event that the primary controller is lost or otherwise inoperable.
---|---|---
2.      Within 1 second, press On/Off

button again for 5 seconds.

3.      IDs are excluded.| LED 2s On, 2s Off (No

node ID)

� Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node ID allocated by Z-Wave Controller means exclusion.

�Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller.

� Sometimes people are not easy to execute exclusion or inclusion especially when PAN30 already installed in a wall box. To solve this issue, PAN30 support a special feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association” at the first 3

minutes when first time connect to main power.

LED Indication

There is a LED for identify function in the front case. PAN34 support the indicator ID 0x50 (Identify) and Properties ID 0x03, 0x04 and 0x05. To distinguish what mode the switch is in, view from the LED for identification.

State Type LED Indication
Normal Whatever we switch On and off of the PAN30 by S1 S2 or

On/Off button or RF command, the LED will lights up 1 second

| and then off.
---|---
No node ID| Under normal operation, when the Switch has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing S1 S2 or On/Off button, it will

stop flashing temporarily.

Learning| When PAN30 is in learning mode, LED flashes on and off al-

ternately and repeatedly at 0.5 second intervals.

Overload| When overload state occurs, the Switch is disabled of which LED flashes on and off alternately at 0.2 second intervals. Overload state can be cleared by disconnect and reconnect

the Switch to the main power

Installation

Z-WAVE-PAN30-Wall-Switch-fig5

  1.  Put the in wall switch into a wall box and connect the AC power wire L,N to PAN30 connector L, N.
  2. Connect the wall switch to the PAN30 as Fig1 .
  3.  To manually turn ON the Switch, press and release the On/Off button. The LED will light ON for 1 second, and the load plugged into the Switch will also turn ON.
  4.  To manually turn OFF the Switch, simply press and release the On/Off button. The LED will light ON for 1 second and the load plugged into the Switch will turn OFF.

Programming

Basic Command Class / Binary Switch Command Class

PAN30 respond to BASIC and BINARY SWITCH commands that are part of the Z-Wave system.

BASIC_GET / BINARY_SWITCH_GET
Since the switch have two relay, the Switch will report its On/Off state of relay1 and relay2.
Report ON when relay1 or relay2 is ON.
Report OFF when both relay1 and relay2 are OFF.
Basic Get-Command: [Command Class Basic, Basic Get]

Basic Report Command:
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)] Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)] Binary Switch Get- Command: [Command Class Switch Binary, Switch Binary Get] Binary Switch Report Command:
Report OFF: [Command Class Switch Binary, Switch Binary Report, Value =0(0x00)] Report ON: [Command Class Switch Binary, Switch Binary Report, Value = 255(0xFF)]

BASIC_SET / SWITCH_BINARY_SET

Since PAN30 has two relay, all the loads attached to relay1 and relay2 will turn on or off upon receipt of the following commands from a Z-Wave Controller.
[Command Class Basic, Basic Set , Value = 1~99, 255(0xFF)]: the load attached to relay1 and relay2 turns on.
[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to relay1 and relay2 turns off.
[Command Class Switch Binary, Switch Binary Set, Value = 1~99, 255(0xFF)]: the load attached to relay1 and relay2 turns on.
[Command Class Switch Binary , Switch Binary Set, Value = 0(0x00)]: the load attached to relay1 and relay2 turns off.

 Z-Wave’s Groups (Association Command Class Version 2)

The Switch can be set to send reports to the associated Z-Wave devices. It supports groups which every group has five nodes support. Group1 is called Lifeline which support SWITCH_BINARY_REPORT、
METER_REPORT、NOTIFICATION_REPORT、INDICATOR_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION.
Group2 and Group3 support SWITCH_BINARY_REPORT.
Group4 and Group5 support METER_REPORT.

  • For group 1, the Switch will report (1) ON/OFF status of Relay1 and Relay2 (2) Instant Power Consumption (Watt) of Relay1 and Relay2 (3) Accumulated Power Consumption (KWh) of Relay1 and Relay2 to Z-Wave Controller.
  • For group 2, the Switch will report ON/OFF status of Relay1.
  • For group 3, the Switch will report ON/OFF status of Relay2.
  • For group 4, the Switch will report Instant Power Consumption (Watt) and Accumulated Power Consumption (KWh) of Relay1.
  • For group 5, the Switch will report Instant Power Consumption (Watt) and Accumulated Power Consumption (KWh) of Relay2.
 Auto report to Grouping 1 ~ 5(Maximum Node 5)

On/Off Event Report

When “on” or “off” state of relay1 or relay2 has been changed, it will send Binary Switch Report to the nodes of Group1 and Group2. When “on” or “off” state of relay2 has been changed, it will send Binary Switch Report to the nodes of Group1 and Group3. The report value will be on when relay1 or relay2 is on, it will be off when both relay1 and relay2 are off.

Binary Switch Report
ON:[Command Class Switch Binary, Switch Binary Report, Value =255(0xFF)] OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]

 Instant Power Consumption vary over 5% report

When the power consumption of load vary over 5%, it will send Meter report to the nodes of Group1、Group4 and Group5.

Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter
Type = 0x01,Precision = 1,Scale = 0x02,Size = 4,Meter Value(W) ]

 Notification report command

When PAN30 detect the overload, it will send Notification Report to Group1.

The content of Notification Report
Notification report command: [Command_Class_Notification, Notification_Report, Notification Type = 0x08, Event state = 0x08]

Response to Meter Get Command

The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated power consumption(KWH) or (3) AC load Voltage (V) or (4) AC load current ( I ) (5) load power factor (PF) to Z-Wave Controller after receive the Meter Get Command from Z-Wave Controller.

Instant Power Consumption (Watt) of Switch

When receiving Meter Get-Command, it will report Meter Report Command tothe node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)]

Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type = 0x01,Precision = 1,Scale = 0x02,Size = 4,Meter Value(W)]

Example:
Meter Value 1 = 0x00 (W)
Meter Value 2 = 0x00 (W)
Meter Value 3 = 0x03 (W)
Meter Value 4 = 0xEA (W)
Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W

Accumulated Power Consumption (KW/h)

When receiving Meter Get Command, it will report Meter Report Command to the node asked.

Meter Get Command:
[Command Class Meter, Meter Get, Scale = 0x00 KW/h)]

Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01, Meter Type =0x01, Precision = 2,Scale = 0x00,Size = 4,Meter Value (KWh)]

Example:
Scale = 0x00 (KWh)
Precision = 2
Size = 4 Bytes (KW/h)
Meter Value 1 = 0x00(KWh)
Meter Value 2 = 0x01(KWh)
Meter Value 3 = 0x38(KWh)
Meter Value 4 = 0xA3(KWh)
Accumulated power consumption (KW/h) = (Meter Value 265536) + (Meter Value 3256) + (Meter Value 4) = 800.35 (KW/h)

Clearing accumulated power consumption

Whenever re-start counting the accumulated power consumption is needed, you can use Meter Reset Command to clear it.
Meter Reset Command: [Command Class Meter, Meter Reset]

AC load Voltage (V)

When receiving Meter Get Command, it will report Meter Report Command to
the node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)]

Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type
= 0x01,Precision = 1,Scale = 0x04,Size = 2, Meter Value(V)]

Example:
Scale = 0x04 (V)
Precision = 1
Size = 2 (2 Bytes of V)
Meter Value 1 = 0x09(V)
Meter Value 2 = 0x01(V)
AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V)

AC load current ( I )

When receiving Meter Get Command, it will report Meter Report Command to

Meter Report Command:
[Command Class Meter, Meter Get, Scale =0x05(I)] [Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type = 0x01,Precision = 2,Scale = 0x05,Size = 2,Meter Value(I)]

Example:
Scale = 0x05 (I)
Precision = 2
Size = 2 (2 Bytes of I)
Meter Value 1 = 0x01(I)
Meter Value 2 = 0x21(I)
AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A)

load power factor (PF)

When receiving Meter Get Command, it will report Meter Report Command to the node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)]

Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type = 0x01, Precision = 2,Scale = 0x06,Size = 1 Bytes,Meter Value(PF)]

Example:
Scale = 0x06 (PF)
Precision = 2
Size = 1 (1 Byte of PF)
Meter Value 1 = 0x63(PF) (It means that the load power factor is 0.99)

Multi Channel Command Class Version 4

PAN30 also support Muti Channel command class (version 3), which include BINARY_SWITCH_GET, BINARY_SWITCH_SET, BASIC_GET, BASIC_SET, METER_SUPPORTED_GET, METER_RESET, METER_GET
You may control endpoint 1 and 2 or get meter report from endpoint 3 and 4 of PAN30.

 BINARY_SWITCH_GET,

You may get the ON/OFF state from endpoint 1 and 2, when endpoint set to 1, PAN30 will reply state of Relay1. If endpoint set to 2, PAN30 will reply state of Relay2.
Below is an example show a source endpoint 1 send a Get command to PAN30 endpoint 2.

COMMAND_CLASS_MULTI_CHANN EL|

(this is the endpoint of command inquirer here we assume endpoint is 1, if the inquirer doesn’t support multi Channel this value will be 0)

(Bit Address =0;Destination End Point range from 1~2)

(Command Class Switch Binary = 0x25) (Switch Binary Get = 0x02)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x02)
Command Class = 0x25
Command =0x02

Below is the example show PAN30 report to last command

COMMAND_CLASS_MULTI_CHANN EL|

Since the endpoint is 2 so PAN30 will reply ON(0xFF) when Relay2 is ON, report OFF (0x00) when  Relay2 is OFF

(Bit Address =0;Destination End Point)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x02
(Bit Address +Destination End Point = 0x01)
Command Class = 0x25| (Command Class Switch Binary = 0x25) (Switch Binary Report = 0x03)

(ON=0xFF , OFF=0x00)

---|---
Command =0x03
Parameter 1 = 0xFF

 BINARY_SWITCH_SET

By using BINARY_SWITCH_SET Command of Multi Channel Command Class Encapsulation Command, you can switch Relay1 ON/OFF by setting endpoint to 1, or switch Relay2 ON/OFF by setting endpoint to 2.
The example of the command show that switch off relay1 of PAN30

COMMAND_CLASS_MULTI_CHANNE L|

(this is the endpoint of command inquirer here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)

(Bit Address =0;Destination End Point range1~2)

(Command Class Switch Binary = 0x25)

(Switch Binary Set = 0x01)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x01)
Command Class = 0x25
Command =0x01
Parameter 1 = 0x00| (ON=0xFF , OFF=0x00)
---|---

 METER_SUPPORTED_GET

This command is to ask the endpoint of PAN30 what kind of meter data can be reported.
The example show how to get the meter report type

COMMAND_CLASS_MULTI_CHANNE L|

(this is the endpoint of command inquirer here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)

(Bit Address =0;Destination End Point range 3~4)

( Command_Class_Meter_V3 = 0x32) (Meter Supported Get = 0x03)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x03)
Command Class = 0x32
Command =0x03

Below is the example show PAN30 report to last command

COMMAND_CLASS_MULTI_CHANNEL

|

(Command_Class_Meter_V3 = 0x32) (Meter Supported Report = 0x04) (Meter Reset =1, Meter Type=0x01) (Scale Supported =

KWh+W+V+A+Power Factor = 0x75)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address +Destination End Point = 0x01)
Command Class = 0x32
Command =0x04
Parameter 1 = 0x81
Parameter 2 = 0x75

METER_RESET

This command is to reset the Accumulated Power Consumption (KWh) to 0 The example show how to reset the KWh

COMMAND_CLASS_MULTI_CHANNEL

|

(this is the endpoint of command inquirer, here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)

(Bit Address =0;Destination End Point range3~4)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x03)
Command Class = 0x32| ( Command_Class_Meter_V3 = 0x32)

( Meter Reset = 0x05)

---|---
Command =0x05

 METER_GET

Using meter get command to get the KWH, W, V, I, PF from endpoint of PAN30
2-3-5-1 Get KWH from endpoint
Meter GET example:

COMMAND_CLASS_MULTI_CHANNEL

|

(this is the endpoint of command inquirer, here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)

(Bit Address =0;Destination End Point range3~4)

( Command_Class_Meter_V3 = 0x32) (Meter Get = 0x01)

(Scale = KWH = 0x00)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x03)
Command Class = 0x32
Command =0x01
Parameter 1 = 0x00

COMMAND_CLASS_MULTI_CHANNEL

|

(Meter report = Endpoint3)

(Bit Address =0;Destination End Point = command inquirer’s Endpoint value)

(Command_Class_Meter_V3 = 0x32)

(Meter Report = 0x02)

(Scale Bit2 = 0 ,Rate Type = 0x01,Meter Type=0x01)

(Precision = 2,Scale Bit1Bit0 = 0,Size = 4)

Accumulated Power Consumption = 0x000005FD = 15.33 KWh

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address +Destination End Point = 0x01)
Command Class = 0x32
Command =0x02
Parameter 1 = 0x21
Parameter 2 = 0x44
Parameter 3 = 0x00
Parameter 4 = 0x00
Parameter 5 = 0x05
Parameter 6 = 0xFD

Get Instant Power Consumption (Watt) from endpoint

METER_GET example:

COMMAND_CLASS_MULTI_CHANN EL|

(this is the endpoint of command inquirer, here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)

(Bit Address =0;Destination End Point range 3~4)

( Command_Class_Meter_V3 = 0x32) (Meter Get = 0x01)

(Scale = W = 0x02)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x03)
Command Class = 0x32
Command =0x01
Parameter 1 = 0x10

PAN30 Instant Power Consumption (W) Report example:

COMMAND_CLASS_MULTI_CHANNEL

|

(Meter report = Endpoint3)

(Bit Address =0;Destination End Point = command inquirer’s Endpoint value)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address +Destination End Point = 0x01)
AN30 Instant Power Consumption (W) Report example:| AN30 Instant Power Consumption (W) Report example:
---|---
AN30 Instant Power Consumption (W) Report example:
AN30 Instant Power Consumption (W) Report example:
AN30 Instant Power Consumption (W) Report example:
AN30 Instant Power Consumption (W) Report example:
AN30 Instant Power Consumption (W) Report example:
AN30 Instant Power Consumption (W) Report example:
AN30 Instant Power Consumption (W) Report example:

Get load voltage V from endpoint

Meter GET example:

COMMAND_CLASS_MULTI_CHANNE L|

(this is the endpoint of command inquirer, here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x03)| (Bit Address =0;Destination End Point range3~4)

( Command_Class_Meter_V3 = 0x32) (Meter Get = 0x01)

(Scale = V = 0x04)

---|---
Command Class = 0x32
Command =0x01
Parameter 1 = 0x20

PAN30 AC load Voltage report example

COMMAND_CLASS_MULTI_CHANNEL

|

(Meter report = Endpoint3)

(Bit Address =0;Destination End Point

= command inquirer’s Endpoint value)

(Command_Class_Meter_V3 = 0x32) (Meter Report = 0x02)

(Scale Bit2 = 1, Rate Type = 0x01, Meter Type=0x01)

(Precision = 1, Scale Bit1Bit0 = 0x00, Size = 2)

Voltage = 0x0910 = 232.0V

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address +Destination End Point = 0x01)
Command Class = 0x32
Command =0x02
Parameter 1 = 0xA1
Parameter 2 = 0x22
Parameter 3 = 0x09
Parameter 4 = 0x10|
---|---

 Get load current I from endpoint

**** Meter GET example

COMMAND_CLASS_MULTI_CHANNEL

|

(this is the endpoint of command inquirer, here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)

(Bit Address =0;Destination End Point range1~3)

( Command_Class_Meter_V3 = 0x32) (Meter Get = 0x01)

(Scale = A = 0x05)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address +Destination End Point = 0x03)
Command Class = 0x32
Command =0x01
Parameter 1 = 0x28

PAN30 AC load current (I) example:

COMMAND_CLASS_MULTI_CHANNEL

|

(Meter report = Endpoint3)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03

COMMAND_CLASS_MULTI_CHANNEL

|

(Meter report = Endpoint3)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03

 Get power factor PF from endpoint

Meter GET example:

COMMAND_CLASS_MULTI_CHANNE L|

(this is the endpoint of command inquirer, here we assume endpoint is 1,if the inquirer doesn’t support multi Channel this value will be 0)

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address+Destination End Point =| (Bit Address =0;Destination End Point
---|---
0x03)| range3~4)
Command Class = 0x32| ( Command_Class_Meter_V3 = 0x32)
Command =0x01| (Meter Get = 0x01)
Parameter 1 = 0x30| (Scale = PF = 0x06)

PAN30 power factor report example

COMMAND_CLASS_MULTI_CHANNE L|

(Meter report = Endpoint3)

(Bit Address =0;Destination End Point = command inquirer’s Endpoint value)

(Command_Class_Meter_V3 = 0x32) (Meter Report = 0x02)

(Scale Bit2 = 1, Rate Type = 0x01, Meter Type=0x01)

(Precision = 2, Scale Bit1Bit0 = 0x10,

---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address+Destination End Point = 0x01)
Command Class = 0x32
Command =0x02
Parameter 1 = 0xA1
Parameter 2 = 0x51

Z-Wave’s Configuration

Configurat ion

Parameter

| Function| Size (Byte)| Value| Unit| Default| Description
---|---|---|---|---|---|---
1| Watt Meter Report Period| 2| 0 –

0x7FFF

| 5s| 720| 0: Disable W auto Report 1~0x7FFF:

720*5s=3600s=

1 hour

2| KWH Meter Report Period| 2| 0 –

0x7FFF

| 10min| 6| 0: Disable KWH auto Report 1~0x7FFF:

6*10min= 1 hour

3| Threshold of

current for Load Caution

| 2| 10-750| 0.01A| 750| 750*0.01A =

7.5A

4| Threshold of

KWH for Load Caution

| 2| 1-10000| 1KWh| 10000|
5| External| 1| 1-3|  | 1| 1:Edge mode

2:Pulse mode

 | switch mode|  |  |  |  | 3:Edge-Toggle

mode

---|---|---|---|---|---|---
6| Restore switch state mode| 1| 0-2|  | 1| 0 : Switch off 1 : Last switch

state

2 : Switch on

7| Watt differential

report mode

| 1| 0-4|  | 1| 0 : Disable

1 : 5%

 |  |  |  |  | 2 : 10%
 |  |  |  |  | 3 : 15%
 |  |  |  |  | 4 : 20%

 Watt Meter Report Period:

If the setting is configured for 1hour (set value =720), the PAN30 will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). If the setting value is 0, the auto report function of meter Watt will be disabled.

KWH Meter Report Period:

If the setting is configured for 1hour (set value =6), the PAN30 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). If the setting value is 0, the auto report function of meter KWh will be disabled.

 Threshold of current for Load Caution

This is a warning when the current of load over the preset threshold value, if the setting value is 750, when the load current of Relay1 or Relay2 over this value, PAN30 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750.

Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN30 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh.

 External switch mode

Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode.

Edge mode:
this mode is suitable for the bi stable wall switch that has indicator point on the switch, and the same position correspond to same state of relay1 and relay2. if the PAN30 relay change the state because of receiving Z-Wave RF command, it may need two times of change (switch on to off or switch off to on) to let relay back to the correspond state.

Pulse mode:
this mode is suitable for the toggle type wall switch to swap the state of Relay1 or Relay2.

Edge-Toggle mode:
this mode is suitable for the normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1 or Relay2.

Restore switch state mode

Whenever the AC power return from lost, PAN30 will restore the switch state which could be SWITCH OFF、LAST SWITCH STATE、SWITCH ON. The default setting is LAST SWITCH STATE.

Watt differential report mode :

Disable :
The function of Watt differential report will be disabled.

5% : When the differential value of Watt is over 5%, PAN30 will send a meter report to the associated group.

10% : When the differential value of Watt is over 10%, PAN30 will send a meter report to the associated group.

15% : When the differential value of Watt is over 15%, PAN30 will send a meter report to the associated group.

20% : When the differential value of Watt is over 20%, PAN30 will send a meter report to the associated group.

Firmware update over the air (OTA)

PAN30 is based on 700 series SoC and supports Firmware Update Command Class, it can receives the updated firmware image sent by controller via the Z-Wave RF media. It is a helpful and convenient way to improve some function if needed.

Command Classes

The Switch supports Command Classes including

Command Class Version Required Security Class
Z-Wave Plus Info 2 None
--- --- ---
Security 0 1 None
Security 2 1 None
Supervision 1 None
Transport Service 2 None
Association 2 Highest granted Security Class
Association Group Information 3 Highest granted Security Class
Basic 2 Highest granted Security Class
Binary Switch 2 Highest granted Security Class
Configuration 4 Highest granted Security Class
Device Reset Locally 1 Highest granted Security Class
Firmware Update Meta Data 5 Highest granted Security Class
Indicator 3 Highest granted Security Class
Manufacturer Specific 2 Highest granted Security Class
Meter 5 Highest granted Security Class
Multi Channel Association 3 Highest granted Security Class
Multi Channel Command 4 Highest granted Security Class
Notification 8 Highest granted Security Class
Powerlevel 1 Highest granted Security Class
Version 3 Highest granted Security Class
--- --- ---

Disposal

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

Philio Technology Corporation
8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257,Taiwan(R.O.C)
www.philio-tech.com

FCC Interference Statement

This equipment has been tested and found to comply with the limit’s for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide rea-sonable protection against harmful interference in a residential installation. This equip-ment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio com-munications. However, there is no guarantee that interference will not occur in a particu- lar installation. If this equipment does cause harmful interference to radio or television re-ception, which can be determined by turning the equipment off and on, the user is en-couraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  •  Increase the separation between the equipment and receiver.
  •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  •  Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

FCC Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.