SONBEST SM5389V 0-5V Outdoor Aluminum Wind Speed and Direction Integrated Sensor User Manual

June 6, 2024
SONBEST

SM5389V
0-5V outdoor aluminum wind speed and direction integrated sensor
User Manual
File Version: V21.6.11

SONBEST SM5389V 0-5V Outdoor Aluminum Wind Speed and Direction Integrated
Sensor

SM5389V uses the standard, easy access to PLC, DCS, and other instruments or systems for monitoring wind speed, and conductivity state quantities. The internal use of high-precision sensing core and related devices to ensure high reliability and excellent long-term stability can be customized.

RS232,RS485,CAN,4-20mA,DC0~5V\10V,ZIGBEE,Lora,WIFI,GPRS and other output methods.

Technical Parameters

Technical parameter Parameter value
Brand SONBEST
Wind speed range 0~30m/s
Start wind 0.2m/s
Wind speed accuracy ±3%
Shell material aluminum
Wind direction range 0~360°
Wind direction resolution 22.5°
Power DC12~24V 1A
Running temperature -40~80°C

Product Selection

Product DesignDC0-5V, DC0-10VMultiple output methods, the products are divided into the following models depending on the output method.

Product model  output method
SM5389V5 DC0-5V
SM5389V10 DC0-10V

Product Size

SONBEST SM5389V 0-5V Outdoor Aluminum Wind Speed and Direction Integrated
Sensor - Dayagram

How to wiring?SONBEST SM5389V 0-5V Outdoor Aluminum Wind Speed and
Direction Integrated Sensor - Model

Note: When wiring, connect the positive and negative poles of the power supply first and then connect the signal wire.

Application solution

SONBEST SM5389V 0-5V Outdoor Aluminum Wind Speed and Direction Integrated
Sensor - Convartion voltmitar ammetar

16- DIMENSIONAL MAP OF WIND DIRECTION

SONBEST SM5389V 0-5V Outdoor Aluminum Wind Speed and Direction Integrated
Sensor - Map

How to use it?

SONBEST SM5389V 0-5V Outdoor Aluminum Wind Speed and Direction Integrated
Sensor - Pic

  1. wind speed and DC0-5Vvoltage computing relationship.
    For example, the range is 0~30m/s, the analog output is 0~5V DC0-5Vvoltage signal, wind speed and
    DC0-5Vvoltage The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is wind speed range upper limit, A1 is the lower limit of the range, B2 is the DC0-5Vvoltage output range upper limit, B1 is the lower limit, X is the currently read wind speed value, and C is the calculated
    DC0-5Vvoltage value. The list of commonly used values is as follows:
DC0-5Vvoltage(V) wind speed value (m/s) Calculation Process
0 0 (30-0)*(0-0)÷ (5-0)+0
1 6 (30-0)*(1-0)÷ (5-0)+0
2 12 (30-0)*(2-0)÷ (5-0)+0
3 18 (30-0)*(3-0)÷ (5-0)+0
4 24 (30-0)*(4-0)÷ (5-0)+0
5 30 (30-0)*(5-0)÷ (5-0)+0

As shown in the above formula, when measuring 2.5V, the current DC0-5Vvoltage is 15m/s。

  1. conductivity and DC0-5Vvoltage computing relationship
    For example, the range is 0~360°, the analog output is 0~5V DC0-5Vvoltage signal, conductivity and
    DC0-5Vvoltage The calculation relationship is as shown in the formula: C = (A2-A1) (X-B1) / (B2-B1) + A1, where A2 is the conductivity range upper limit, A1 is the lower limit of the range, B2 is DC0 -5Vvoltage output range upper limit, B1 is the lower limit, X is the currently read conductivity value, and C is the calculated
    DC0-5Vvoltage value. The list of commonly used values is as follows: DC0-5Vvoltage(V)| conductivity value (°| Calculation Process
    ---|---|---
    0| 0| (360-0)
    (0-0)÷ (5-0)+0
    1| 72| (360-0)(1-0)÷ (5-0)+0
    2| 144| (360-0)
    (2-0)÷ (5-0)+0
    3| 216| (360-0)(3-0)÷ (5-0)+0
    4| 288| (360-0)
    (4-0)÷ (5-0)+0
    5| 360| (360-0)*(5-0)÷ (5-0)+0

As shown in the above formula, when measuring 2.5V, the current DC0-5Vvoltage is 180°。

  1. wind speed and DC0-10Vvoltage computing relationship.
    For example, the range is 0~30m/s, the analog output is 0~10V DC0-10Vvoltage signal, wind speed and DC0-10Vvoltage The calculation relationship is as shown in the formula: C = (A2-A1) (X-B1) / (B2-B1) + A1, where A2 is wind speed range upper limit, A1 is the lower limit of th e range, B2 is DC0-10Vvoltage output range upper limit, B1 is the lower limit, X is the currently read wind speed value, and C is the calculated DC0-10Vvoltage value. The list of commonly used values is as follows: DC0-10Vvoltage(V)| wind speedValue (m/s)| Calculation Process
    ---|---|---
    0| 0| (30-0)
    (0-0)÷ (10-0)+0
    1| 3| (30-0)(1-0)÷ (10-0)+0
    2| 6| (30-0)
    (2-0)÷ (10-0)+0
    3| 9| (30-0)(3-0)÷ (10-0)+0
    4| 12| (30-0)
    (4-0)÷ (10-0)+0
    5| 15| (30-0)(5-0)÷ (10-0)+0
    6| 18| (30-0)
    (6-0)÷ (10-0)+0
    7| 21| (30-0)(7-0)÷ (10-0)+0
    8| 24| (30-0)
    (8-0)÷ (10-0)+0
    9| 27| (30-0)(9-0)÷ (10-0)+0
    10| 30| (30-0)
    (10-0)÷ (10-0)+0

As shown in the above formula, when measuring 5V, the current DC0-10Vvoltage is 15m/s。

  1. conductivity and DC0-10Vvoltage computing relationship.
    For example, the range is 0~360°, the analog output is 0~10V DC0-10Vvoltage signal, conductivity, and DC0-10Vvoltage The calculation relationship is as shown in the formula: C = (A2-A1) (X-B1) / (B2-B1) + A1, where A2 is conductivity range upper limit, A1 is the lower limit of the range, B2 is D C0-10Vvoltage output range upper limit, B1 is the lower limit, X is the currently read conductivity value, and C is the calculated DC0-10Vvoltage value. The list of commonly used values is as follows: DC0-10Vvoltage(V)| conductivityValue (°)| Calculation Process
    ---|---|---
    0| 0| (360-0)
    (0-0)÷ (10-0)+0
    1| 36| (360-0)(1-0)÷ (10-0)+0
    2| 72| (360-0)
    (2-0)÷ (10-0)+0
    3| 108| (360-0)(3-0)÷ (10-0)+0
    4| 144| (360-0)
    (4-0)÷ (10-0)+0
    5| 180| (360-0)(5-0)÷ (10-0)+0
    6| 216| (360-0)
    (6-0)÷ (10-0)+0
    7| 252| (360-0)(7-0)÷ (10-0)+0
    8| 288| (360-0)
    (8-0)÷ (10-0)+0
    9| 324| (360-0)(9-0)÷ (10-0)+0
    10| 360| (360-0)
    (10-0)÷ (10-0)+0

As shown in the above formula, when measuring 5V, the current DC0-10Vvoltage is 180°。
Disclaimer
This document provides all information about the product, does not grant any license to intellectual property, does not express or imply, and prohibits any other means of granting any intellectual property rights, such as the statement of sales terms and conditions of this product, other issues. No liability is assumed. Furthermore, our company makes no warranties, express or implied, regarding the sale and use of this product, including the suitability for the specific use of the product, the marketability, or the infringement liability for any patent, copyright, or other intellectual property rights, etc. Product specifications and product descriptions may be modified at any time without notice. Contact Us
Company: Shanghai Sonbest Industrial Co., Ltd
Address: Building 8, No.215 Northeast Road, Baoshan District, Shanghai, China
Web: http://www.sonbest.com
Web: http://www.sonbus.com
SKYPE: soobuu
Email: sale@sonbest.com
Tel: 86-021-51083595 / 66862055 / 66862075 / 66861077

Sha nghai Sonbest Industrial Co., Ltd

Documents / Resources

| SONBEST SM5389V 0-5V Outdoor Aluminum Wind Speed and Direction Integrated Sensor [pdf] User Manual
SM5389V, 0-5V Outdoor Aluminum Wind Speed and Direction Integrated Sensor, SM5389V 0-5V Outdoor Aluminum Wind Speed and Direction Integrated Sensor
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SONBEST User Manuals

Related Manuals