Introduction

091FL/091FLRF is a programmable, weekly thermostat used to control room temperature in heating or cooling systems. Before use please read this manual carefully. Use only AA 1.5V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the cover. Do not use rechargeable batteries.

Safety Information

Use in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations.

Technical specification

Wired thermostat 091FL

Power supply 2 x AA batteries
Rating max 5 (3) A
Outputs Voltage-free NO/COM relay
Temperature range 5 – 30°C

Wireless thermostat 091FLRF

Thermostat supply 2 x AA batteries
Receiver supply 230 V AC 50 Hz
Receiver rating max 16 (5) A
Receiver outputs Voltage-free NO/COM relay
Temperature range 5 – 30°C

Proper thermostat placement

Button Functions

Button Function
Comfort temperature or changing parameters up
Economic temperature or changing parameters down
Set the day of the week
Set the hour
Set the minutes
Temperature set point

| Weekly programming
| Program selection
| Confirm function
Reset| Factory Reset

LCD Icon description

LCD Icon description

  1. Day of the week indicator
  2. Heating Mode ON
  3. Cooling Mode ON
  4. Room / setpoint temperature
  5. Temperature unit
  6. Controlled device working status (e.g. boiler)
  7. Temporary override
  8. Eco Mode
  9. Program number
  10. Antifrost Mode
  11. Comfort Mode
  12. Program timeline indicator
  13. Clock
  14. Low battery indicator
  15. AM/PM

091FL Wiring diagram

091FLRF Wiring diagram

091FLRF Wiring diagram`

CHANGING THE COMMUNICATION CODE OF 091FLRF Note: To prevent interference from other wireless devices it is recommended to change the communication code from factory setting.

  1. Use DIP switches (numbered 1-5) to change the communication code.
    DIP switches

  2. Set DIP switches randomly – they need to be in the same position on both the receiver and the transmitter.

  3. Press Reset button after communication code changing.
    Resect

Setting Time

Press button to highlight the display.

Press to set the day.

press to set the hour

Press to set the minutes

Setting the comfort temperature

  1. Press button to highlight the display.
    Press and then press .

  2. Setting the comfort temperature
    Display will show current comfort temperature.
    To change this temperature, press or button.

Setting the economic temperature

  1. Press button to highlight the display.
    Press and then press .

  2. Setting the economic temperature
    Display will show current economic temperature.
    To change this temperature, press or button.

  3. To confirm press button.

Programs

Temperature Instructions

Comfort temperature

Economic temperature

There are 9 programs available. Programs 0-5 are factory programs.
Programs 6-8 can be defined by user

Selection of factory (0-5) programs

  1. Press to highlight the display.
    Select the day of the week by pressing button.

  2. Press to set the program number (0-5) for the selected day.
    Prog Instructions
    Program 0 is a special program. It will set the thermostat to antifrost temperature (7°C) for the full day.
    Instructions

  3. To confirm press button.

NOTE! Label with programs descriptions is sticking on the flip side of the cover.

Choosing and programming (6-8) user programs

  1. Press to highlight the display.
    Select the day of the week by pressing button.

  2. Press to set the program number (6, 7 or 8) for the selected day.

  3. programming
    Press or button (each pressing one of these buttons moves the timeline by one hour and assigns a comfortable or an economic temperature).

  4. To confirm press button.

Service menu

Press button to highlight the display. Then open service menu by holding button for 5 seconds.

  1. Heating mode – the relay closes the contacts when there is a need for heating (default setting).
    Cooling mode – the relay closes the contacts when there is a need for cooling (with 5 minutes delay).
    Press or to select mode.
    To confirm your option press .

  2.  – Heating device delay switch disabled (default setting).
    Heating device delay switch is ON (5 min)
    Select by pressing or button.
    To confirm your option press .

  3. Temperature span selection, possible values are 0.5°C or 1.0°C (default = 1.0°C).
    Press or to set span.
    To confirm your option press .

  4. – **Measured temperature correction*** (value range: -3.0°C to + 3.0°C, default = 0.0°C).
    Press or to set correction.
    To confirm your option press .

  • this feature is available from 2.4 software version programs. Programs 6-8 can be defined by user.

Product compliance

This product complies with the following EU Directives:
091FL: 2014/30/EU, 2014/35/EU, 2011/65/EU
091FLRF: 2011/65/EU, 2014/53/EU 868.0 MHz – 868.6 MHz; <13dBm
Full information is available on the website www.saluslegal.com

PRODUCER:
Salus Limited
6/F, Building 20E, Phase 3, Hong
Kong Science Park, 20 Science Park
East Avenue, Shatin, New Territories,
Hong Kong

IMPORTER:
QL CONTROLS Sp. z o.o. Sp. k.
ul. Rolna 4, 43-262 Kobielice

www.salus-controls.eu

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals