microsonic 10040157 Mic+ Ultrasonic Sensors with One Switching Output User Manual

June 6, 2024
microsonic

microsonic 10040157 Mic+ Ultrasonic Sensors with One Switching Output

Models

  • mic+25/D/TC mic+25/E/TC
  • mic+35/D/TC mic+35/E/TC
  • mic+130/D/TC mic+130/E/TC
  • mic+340/D/TC mic+340E/TC
  • mic+600/D/TC mic+600/E/TC

Product description

  • The mic+ sensor with one switching out-put offers a non-contact measurement of the distance to an object. Depending on the adjusted detect distance the switch-ing output is set.
  • All settings are done with two push buttons and a three-digit LED display (Touch-Control).
  • Light-emitting diodes (three-color LEDs) indicate the switching status.
  • The output functions are changeable from NOC to NCC.
  • The sensors are adjustable manually using the numerical LED display or maybe trained via the Teach-in procedure.
  • Useful additional functions are set in the Add-on-menu.
  • Using the LinkControl adapter (optional accessory) all TouchControl and additional sensor parameter settings may be made by Windows software.

Important instructions for assembly and application

All employee and plant safety-relevant measures must be taken prior to assembly, start-up, or maintenance work (see operating manual for the entire plant and the operator instruction of the plant).
The sensors are not considered as safety equipment and may not be used to ensure human or machine safety! The mic+ sensors indicate a blind zone, in which the distance cannot be measured. The operating range indicates the distance of the sensor that can be applied with normal re-flectors with sufficient function reserve. When using good reflectors, such as a calm water surface, the sensor can also be used up to its maximum range. Objects that strongly absorb (e.g. plastic foam) or diffusely reflect sound (e.g. pebble stones) can also reduce the defined operating range.

Synchronization
If the assembly distances shown in fig.1 for two or more sensors are exceeded the integrated synchronization should be used. Connect Sync/Com channels (pin 5) of all sensors (10 maximum).

Minimal assembly distances without
synchronization or multiplex mode.

Multiplex mode
The Add-on-menu allows assigning an individual address »01« to »10« to each sensor connected via the Sync/Com-channel (pin 5). The sensors perform the ultrasonic measurement sequentially from low to high address. Therefore any influence between the sensors is rejected. The address »00« is reserved for synchronization mode and deactivates the multiplex mode. (To use synchronized mode all sensors must be set to address »00«.)

Assembly instructions

  • Assemble the sensor at the installation location.
  • Plugin the connector cable to the M12 connector.

Pin assignment with view onto sensor plug and colour coding of the microsonic connection cable.

Start-up
mic+ sensors are delivered factory made with the following settings:

  • Switching output on NOC
  • Detecting distance at operating range
  • Measurement range set to maximum range.

Set the parameters of the sensor manually or use the Teach-in procedure to adjust the switching points. microsonic-10040157-Mic+-Ultrasonic-Sensors-
with-One-Switching-Output-fig-3

TouchControl

Maintenance

mic+ sensors work maintenance free. Small amounts of dirt on the surface do not influ-ence function. Thick layers of dirt and caked-on dirt affect sensor function and therefore must be removed.

Note

  • mic+ sensors have internal temperature compensation. Because the sensors heat up on their own, the temperature compensation reaches its optimum working point after approx. 30 minutes of operati-on.
  • During normal mode operation, a yellow LED D2 signals that the switching output is set.
  • During normal operating mode, the measured distance value is displayed on the LED display in mm (up to 999 mm) or cm (from 100 cm). Scale switches automatically and is indicated by a point on top of the digits.
  • During Teach-in mode, the hysteresis values is set back to factory settings.
  • If no objects are placed within the detection zone the LED display shows »- – -«.
  • If no push-buttons are pressed for 20 seconds during parameter setting mode, the parameter changes are saved and the sensor returns to normal operating mode.
  • You can lock the key pad to provide in- puts, see »Key lock and factory setting«.
  • You can reset the factory settings at any time, see »Key lock and factory setting«. Show parameters Tapping push-button T1 shortly during nor-mal operating mode shows »PAr« on the LED display. Each time you tap push-button T1 the actual settings of the switching output are displayed.

Set sensor parameters alternatively numerically using LED display or with

the Teach-in procedure

microsonic-10040157-Mic+-Ultrasonic-Sensors-with-One-Switching-Output-
fig-4 microsonic-10040157-Mic+-Ultrasonic-Sensors-with-One-Switching-Output-
fig-5

Key lock and factory setting

Useful additional functions in Add-on menu (for experienced users only,

settings not required for standard applications)

microsonic-10040157-Mic+-Ultrasonic-Sensors-with-One-Switching-Output-
fig-7

Technical data

mic+25

microsonic-10040157-Mic+-Ultrasonic-Sensors-with-One-Switching-Output-
fig-10 microsonic-10040157-Mic+-Ultrasonic-Sensors-with-One-Switching-Output-
fig-15

mic+35

microsonic-10040157-Mic+-Ultrasonic-Sensors-with-One-Switching-
Output-fig-11 microsonic-10040157-Mic+-Ultrasonic-Sensors-
with-One-Switching-Output-fig-16

mic+130

microsonic-10040157-Mic+-Ultrasonic-Sensors-with-One-Switching-
Output-fig-12 microsonic-10040157-Mic+-Ultrasonic-Sensors-
with-One-Switching-Output-fig-17

mic+340

microsonic-10040157-Mic+-Ultrasonic-Sensors-with-One-Switching-
Output-fig-13 microsonic-10040157-Mic+-Ultrasonic-Sensors-
with-One-Switching-Output-fig-18

mic+600

microsonic-10040157-Mic+-Ultrasonic-Sensors-with-One-Switching-
Output-fig-14 microsonic-10040157-Mic+-Ultrasonic-Sensors-
with-One-Switching-Output-fig-19

Can be programmed with TouchControl and LinkControl 2) With TouchControl and LinkControl, the selected filter setting and the maximum range influence the switching frequency. microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 E info@microsonic.de / W microsonic.de / The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

microsonic User Manuals

Related Manuals