Amico FSL503TB LED Security Flood Lights User Manual
- June 14, 2024
- Amico
Table of Contents
Amico FSL503TB LED Security Flood Lights User Manual
INSTALLATION VIDEO
Need a Video Instruction Guide?
Please scan the QR code.
If the QR code is invalid, please contact us for the video.
SAFETY INFORMATION
- This product must be installed and operated by professional electricians according to the installation instructions.
- This fixture is designed for using 120VAC, 60Hz. Do not use DC power.
- Before installing the light fixture, ensure that all parts are present and same as the part list. If any part is missing or damaged, do not attempt to assemble, install, or operate this light fixture.
- Turn off the power and make sure the power is off before installing the light fixture.
- This lamp is not dimmable, do not connect to a dimmer.
- When using the light fixture, do not cover by any combustible materials to avoid fire.
- Burn warned. Don’t touch the light fixture before cooling.
- This device complies with the FCC Rules.
- Install the height of the light fixture not lower than 6.0FT, to avoid disturbance from small animals on the ground within detection range.
- Try to install this light fixture in the place without metal halide lamp, if can’t avoid, install the light fixture 10FT away from the irradiation scope of metal halide lamp.
- The light fixture should be installed away from the place like air conditioning, refrigerators, furnace, which provided sensitive to air temperature change, as well as windows and other strong hot air flow places, so as not to cause wrong action.
- When the air temperature is close to a person’s body temperature, the detection sensitivity will reduce.
HOW TO INSTALL
MOUNTING IOCATION
- Mounting location: wall or eave mounted.
- Mounting Height: The light fixture should be mounted approximately 8FT (6.2—8.2FT) above the ground. If the light fixture is mounted higher or lower than recommended, the coverage area, distance or sensitivity of the sensor will be changed accordingly.
TOOL NEEDED FOR INSTALLTION
ACCESSORIES LIST
HOW TO INSTALL
-
Step: 1
-
Step: 2
Mount the brackets to the wall connection box. -
Step: 3
Insert the wire through EVA pad, and use spiral connector to connect the junction box wire.
Note: Wiring Connection:
1. L connected Black line ;
2. N connected White line ;
3. Ground wire conneted to green ground screw on fixture together with junction box.
Note: Improper wiring or poor grounding may cause the light to be slightly bright.
-
Step: 4
- Tilt the light head left or right to adjust the light coverage area, see the arrow indication direction 1 and 2 to adjust the light head.
- Tilt the light head up or down to adjust the light coverage area, see the arrow indication direction 3 and 4 to adjust the light head.
SENSOR INSTRUCTIONS
SPECIFICATION
Power Source | AC120V | Wattage | SOW |
---|---|---|---|
Power Frequency | 60 Hz | Detection Distance | 1>RANGE MIN: Within SFT |
Installation Height | 6.0-9.2FT | 2>RANGE MAX: Within 70FT | |
Detection Range | 150º | Time Setting | 1 » Test mode:5 sec |
Detection Motion Speed | 0.6-1.5 rn/s | 2›Motion mode: On-time (1 min-5min-10 |
min)
Working Temperature Power| -14°F-104°F| Working Humidity:| <93%RH
GEAR SETTING INSTRUCTIONS
DISTANCE: Allows you to decide on the distance of detection.
H — Detect motion up to 70 feet.
M — Detect motion up to 40 feet.
L — Detect motion up to 25 feet.
D2D — Off during the day, on at night.
TIME: Induction light holding time.
TEST — Not affected by the light environment, the light remains 5S after
triggering.
1M — Delay 1 minutes to turn off the lights after triggering at night.
5M — Delay 5 minutes to turn off the lights after triggering at night.
10M — Delay 10 minutes to turn off the lights after triggering at night
MODE SETTING UP
( Note: It will enter the warm-up time for 40S when the lamp is turned on, then start mode setting.)
-
TEST MODE (Light on for SS for both day and night when sensing a moving object) Setting Method: Set “TIME” to “TEST”, and set “DISTANCE” to any one of “L/ M /H”. Adjust the “distance” switch can set the sensitivity of the sensor, means changing the sensor’s detection distance, it can be positioned to high, mid and low.
-
MOTION MODE (When the object moves within the range of induction and the brightness of outside is less then 20Lux, the light will be turned off automatically after light on for 1min / Smin / 10min. After 3S , its will enter the motion mode again when sensing a moving object. Light off automatically when the brightness of outside is higher ó0Lux.)
Setting Method:
a. Detection Distance: Set “DISTANCE” to any one of “L/ M / H” according to your application;
b. Lighting up time: Set “TIME” to any one of “1min / Smin / 10min” according to your application. -
DUSK TO DAWN (Light on automatically when the brightness less than 20Lux outside;
Light off automatically when the brightness high than 60Lux outside.) Setting Method: Set “DISTANCE” to “D2D”, and set “TIME” to any one of “1min / Smin / 10min”. -
Always ON mode: When the distance knob is toggled to D2D and the time knob is toggled to TEST, the light flashes 2 times and then stays on.
SETTING THE MOTION SENSOR DETECTION RANGE
-
When the installation height is 6.OFT or below, it is recommended that the motion sensor be set to a horizontal angle so that longer distances can be detected.
-
When the installation height is 8.2FT or above, it is recommended that the motion sensor be set to 5°-10°, the higher the height, the greater the angle of downward adjustment of the motion sensor.
-
Adjustment and setting for the detection distance.
As shown in the picture 1(schematic diagram of the max detection range ).The sensor can be adjusted up 90°or down 100°. When fixture installed on the vertical wall, adjust the sensor to different degree can change the detection distance. Normally, when install the sensor at 5° depression angle, the detection distance is the largest. The detection distance and sensitivity will be changed if mounting height is different. -
Instruction for setting motion sensor detection range.
-
To determine the detection range of motion sensor need to perform a simulation test:
Walking around the motion sensor, if the light lighted up, that’s means motion has been detected and give out lighting signal. Stop walking and wait for the light to turn off, then begin walking again. -
The motion sensor is less sensitive if in a radial movement, half range of max detection distance, As shown below. ( Fig.1 )
-
The motion sensor is more sensitive if in a lateral movement. As shown below. ( Fig.2 )
COMMON TROUBLESHOOTING
PROBLEMS | SOLUTION |
---|---|
light not on | Please make sure the input cable is well connected, input power |
should be 120V/60Hz;
ChecktheACinput
Human Presence Detection feature malfunctioning|
- 0 Please adjust the sensor angle, and make sure the DISTANCE dial underneath the sensor is set to either the M or H setting.
- Installation height is ó.0FT or below, it is recommended that the motion sensor be set to a horizontal angle.
- With a mounting heightof8.2UoraboveUtisrecommendedtosetthemotion sensor to 5°-10° or higher.
The light is always on, the sensor function is invalid| Keep the sensor setup
away from air conditioning units, refrigerators, heaters, and other places
where it may be subject to great fluctuations in temperature to prevent false
triggers. The time dial can be set to 1minute.
Presence of water inside of sensor| Make sure the sensor probe is turned to
the correct position.
After turning it off, the light is always on| Check whether the input L line
and N line are connected correctly.
| Please contact us for further inquiries
CONTACT US
-
Log into your Amazon.com account, click “Returns&Orders” on the top-right corner.
-
Find your order in the list and click “View order details”
-
Click the “Store Name” following the Sold by, below the product title.
-
Click the yellow button “Ask a question” on the top-right corner, to contact the seller.
Should you experience any issues while operating any of our products, you can directly reach out to our Customer Support via Amazon Orders. Or you can send your inquiry to our Official Customer Support at:
Call us:
+1(626)313-9318
Monday – Friday from 9:00AM – 5:00PM (PT)
Contact via Email: support@amicolight.com
CUSTOMER SERVICE
-
30-Day Return Policy
If you’re not completely satisfied with your purchase, simply return the merchandise via Amazon Orders.
Unused merchandise can be refunded or exchanged within 30 days from the original purchase date. -
3-Year Warranty
We guarantee your product is free from defects in product material and workmanship for three (3) years starting from the date of purchase during normal use of household conditions. If your appliance fails to operate properly within our warranty period, we will arrange a new replacement free of charge and cover all the shipping costs. -
Quick Response within 12 Hours
If you are still unable to resolve the issue you are experiencing, please contact us immediately at our support email. It doesn’t matter if the product has been installed, our customer support team will respond within 12 hours and assist you quickly and efficiently. The most efficient way to confirm your problem to us is to attach a video illustrating your product issue.
GET MORE SUPPORT
Should you experience any issue while operating any of products, you can directly reach out to our Customer Support via Amazon Orders, Or you can inquiry to our Official Customer Support at:
support@amicolight.com
+1(626)313-9318
Monday – Friday from 9:00AM – 5:00PM (PT)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>