ABOUT THIS INSTRUCTION MANUAL
These operating instructions are to be considered a component of the device.
Please read the safety instructions and the operating instructions carefully
before use. Keep these instructions for renewed use at a later date. When the
device is sold or given to someone else, the instruction manual must be
provided to the new owner/user of the product.
This product is intended only for private use. It was developed as an
electronic medium for the use of multimedia services.
GENERAL WARNINGS
RISK OF CHOKING!
Keep packaging material, like plastic bags and rubber bands, out of the reach
of children, as these materials pose a choking hazard.
RISK of ELECTRIC SHOCK!
This device contains electronic components that operate via a power source
(batteries). Children should only use the device under adult supervision. Only
use the device as described in the manual; otherwise, you run the risk of an
electric shock.
RISK OF CHEMICAL BURN!
Leaking battery acid can lead to chemical burns. Avoid contact of battery acid
with skin, eyes and mucous membranes. In the event of contact, rinse the
affected region immediately with a plenty of water and seek medical attention.
RISK of FIRE/EXPLOSION!
Use only the recommended batteries. Do not short-circuit the device or
batteries, or throw them into a fire. Excessive heat or improper handling
could trigger a short-circuit, a fire or an explosion.
NOTE!
Do not disassemble the device. In the event of a defect, please contact your
dealer. The dealer will contact the Service Centre and can send the device in
to be repaired, if necessary.
Do not immerse the unit in water.
- Do not subject the unit to excessive force, shock, dust, extreme temperature or high humidity, which may result in malfunction, shorter electronic life span, damaged batteries and distorted parts.
- Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity. Do not use batteries from different brands or with different capacities. Remove the batteries from the unit if it has not been used for a long time.
- The manufacturer is not liable for damage related to improperly installed batteries!
SCOPE OF DELIVERY (Fig. 1)
Main unit (A), outdoor sensor (B), instruction manual
PARTS OVERVIEW
Main unit (Fig. 2)
-
Outdoor temperature
-
Outdoor humidity
-
Low battery indicator (main unit)
-
MIN/MAX value for outdoors
-
LIGHT button
-
Indoor humidity indicator
-
Atmospheric change indicator
-
Ventilation indicator (Window)
-
Low battery indicator (outdoor sensor)
-
Current time
-
AM/PM information on 12-hours time display mode
-
Touch controls (a) MEM/ (b) AL/SET (c) CH/
-
Sensor channel
-
Indoor temperature
-
MIN/MAX value for indoors
-
Indoor humidity
-
Wall mount hanger
-
Fold-out stand
-
Battery compartment
-
Battery compartment cover
Outdoor sensor (Fig. 3) -
Outdoor temperature and humidity
-
Outdoor temperature and humidity
-
Wall mount hanger
-
CH switch
-
Battery compartment
-
Battery compartment cover
BEFORE YOU START
IMPORTANT!
- Insert batteries for remote units before doing so for the main unit.
- Place the main unit as close as possible to the remote unit.
- Position the remote unit and main unit within the effective transmission range.
When changing batteries always change batteries in the main unit as well as all remote units and replace them in the correct order, so the remote connection can be re-established. If batteries are exchanged in only one of the devices (i.e. the remote sensor) the signal can’t be received or can’t be received correctly.
Note, that the effective range is vastly affected by building materials and position of the main and remote units. Due to external influences (various RC devices and other sources of interference), the maximum distance can be greatly reduced. In such cases we suggest to position the main unit and the outdoor sensorat other places. Sometimes all it takes is a relocation of one of these components of a few inches!
Though the remote unit is weather proof, it should be placed away from direct sunlight, rain or snow.
POWER SUPPLY
Main unit (Weather station)
- Remove the battery compartment cover (20).
- Install 3 batteries (AAA size 1.5V) strictly according to the polarities shown.
- Reinsert the battery compartment cover.
Outdoor sensor
- Remove the battery compartment cover (26).
- Move the CH switch (24) to the position (1-3) that corresponds with the channel which will be used for transmission (select channel 1 if only one sensor is connected).
- Install 2 batteries (AAA size 1.5V) strictly according to the polarities shown.
- Reinsert the battery compartment cover.
Low battery indication
When batteries need to be replaced the respective low battery indicator for
the main unit (3) or the outdoor sensor (9) will be shown on the display of
the main unit.
USING TABLE STAND OR WALL MOUNTING
The main unit can be placed on a flat surface (e.g. table) with the fold-out
stand (18).
The main unit and the outdoor sensor can be mounted on walls using the
recessed wall mount hanger (17, 23).
OPERATION
Receiving measurements
Once batteries are installed to the outdoor sensor, it will start transmitting
temperature readings at roughly 60 second intervals. As soon as batteries are
installed in the main unit it will start searching for a signal from the
outdoor sensor for about 3-4 minutes. Upon successful reception of the signal,
the outdoor temperature will be displayed on the main unit. The main unit will
automatically update its readings at about 60 second intervals.
NOTE! When the outdoor temperature is above or below the measurement range, the display will show HHH (high) or LLL (low).
Manual time setting and other settings
To make manual settings, proceed as follows:
- In normal time mode press the CF/SET touch control (12b) for approx. 3 seconds to enter the settings mode. The value to be set is flashing. Value settings order: hours > minutes > 12/24 hours > On/Off
- Press MEM/〉 or CH/ to set the hours for the current time.
- Press CF/SET to switch to the next setting.
- Press MEM/ or CH/ to set minutes for the current time.
- Press CF/SET to switch to the next setting.
- Press MEM/ or CH/ to select 12 or 24 hours time mode.
- Press CF/SET to switch to the next setting.
- Press MEM/ or CH/ to switch between ON or OF to enable or disable 24 hour measurement data storage.
- Press CF/SET to save and exit settings mode. If there is no operation for 20 seconds, the existing setting will be saved and the device returns to normal display mode.
NOTE! When choosing ON for 24 hour measurement data storage all stored MIN/MAX values for temperature and humidity will be deleted daily at 0:00h!
When choosing OFF the data will be stored indefinitely until a battery change is required.
Temperature and humidity
- Once the batteries are installed the main unit will start displaying the interior measurement information. The main unit will display the information from the outdoor sensor for the first time approximately 3-4 minutes after the power supply was established.
- Press CF/SET touch control (12b) to switch screen display between °C or °F. Screen display will change for outdoor temperature as well as for indoor temperature.
Indoor humidity indicator
The indoor humidity indicator (6) displays the following conditions:
WET | WET | Indoor humidity between 66% and 95% |
---|---|---|
COMFORT | COMFORT | Indoor humidity between 45% and 65% |
DRY | DRY | Indoor humidity between 20% and 44% |
NOTE! Read chapter “Ventilation indicator” for more information.
Temperature and humidity MAX/MIN records
-
Press the touch control MEM/ (12a) several times to switch between the values for current, minimum (MIN) and maximum (MAX) temperature and humidity. The display will change for the indoor temperature as well as for the outdoor temperature.
-
The MIN/MAX temperature and humidity values will be recorded automatically.
NOTE! Depending on the selected type for measurement data storage the MIN/MAX values will be saved for 24 hours or until batteries need to be changed (Read chapter “Manual time setting and other settings”). -
Press MEM/ touch control for approx. 3 seconds to delete MIN/MAX values manually.
Atmospheric change
The device uses the measurement data to calculate the absolute humidity.
The icons indicate how the ventilation would affect the indoor climate:
NOTE! Read chapter “Ventilation indicator” for more information.
Ventilation indicator
The ventilation indicator (8) relies on the information of the atmospheric
change (7) and the indoor humidity indicator (6). It is shown on the display
as follows:
NOTE! To ensure the ventilation indicator can function as required, the outdoor sensor must be placed outdoors, otherwise the result can not be calculated properly.
IMPORTANT! Windows should be opened wide for a short time (a few minutes) for effective ventilation. If possible, open windows on opposite sides of the apartment (full ventilation).
Even if ventilation is not recommended by the weather station due to the humidity, the apartment should be ventilated regularly. This contributes to the reduction of pollutants and other volatile compounds in the room air.
Humidity comfort level
| Ambient change
| Open window
| Close window
---|---|---|---
COMFORT| MORE DRY, MORE WET OR NO CHANGE| off| off
DRY| NO CHANGE| off| off
DRY| MORE WET| on| off
DRY| MORE DRY| off| on
WET| NO CHANGE| off| off
WET| MORE WET| off| on
WET| MORE DRY| on| off
Main unit signal receivement check
The transmission range is about 50 meters from the outdoor sensor to the main unit (in open area). The main unit should receive the temperature/humidity information from the transmitter within 3-4 minutes after set-up. Should the main unit not receive information from transmitter within 3-4 minutes after setting up, please check following steps:
- Press and hold the touch control CH/ (12c) for 2-3 seconds to re-start receiving from the transmitter; the data will normally be received within 3 minutes.
- If the first step does not yield a desirable solution, please remove the batteries and re-install them (hardware reset).
At the same time, please make sure the following:
- The main unit as well as the sensor should be at least 5 to 6 feet (1.5 to 2 meters) away from any interfering sources, such as computer monitors or TV sets.
- The main unit should not stand close to metal window frames.
- Please do not use other electrical products, such as headphones or speakers, operating on the same signal frequency (433 MHz).
- Electrical devices operating on the same signal frequency may also cause interference. This can include devices used in the neighborhood as well.
Main unit channel setting
- The main unit can be connected with a maximum of up to 3 transmitters.
- Press the touch control CH/ (12c) to switch between the displays of each channel. The main unit will display the information of the corresponding transmitter. When the symbol is displayed near the channel information the automatic display rotation is activated. The display changes between the information of the connected remote sensors every 10 seconds.
NOTE! The function to change the channels by pressing the CH/ button can be used only if more than one outdoor sensor is connected with the main unit. Otherwise this function is disabled.
Background illumination
Press LIGHT button (5) to to turn on the background. It will be turned off
automatically after approx. 5 seconds.
Sensor function
- Move the CH switch (24) to the position (1-3) that corresponds with the channel which will be used for transmission (select channel 1 if only one outdoor sensor is connected). If you would like to connect more than one outdoor sensor with the main unit, different channels need to be selected for each sensor.
- Once the weather station receives radio signals from the sensors, the alternating temperature values of the different channels will be updated on the weather station every 1-2 minutes.
TROUBLESHOOTING
Signal disconnection
If the display of the outdoor temperature goes blank without obvious reasons,
please check the following:
-
The outdoor sensor is still in place.
-
The batteries of both the sensor and the main unit are not empty. Replace batteries with new ones if necessary.
NOTE! When the temperature drops below freezing point, the batteries of the outdoor sensor can also freeze and their voltage and lifetime are reduced. -
Both devices are positioned within the reception area and the reception area is free of sources of interference and obstacles. If necessary, reduce the distance between the devices.
Transmission collision
Signals from other household devices, such as door bells, home security
systems and entry controls, may interfere with those of this product and cause
temporarily reception failure. This is normal and does not affect the general
performance of the product. The transmission and reception of temperature
readings will resume once the interference recedes.
TECHNICAL DATA
Measurement
Temperature rage indoors/outdoors: -9 to 50° C / -40 to 60° C
Humidity range: 20% to 95%
Transmission
Transmission range: 50m (in free area)
Transmission frequency: 433 MHz
Maximum transmission power: < 10 mW
Power supply
Main unit: 3x AAA/LR03 1.5V batteries
Wireless sensor: 2x AAA/LR03 1.5V batteries
OPTIONAL ACCESSORY
Thermo-Hygrosensor, Art. No. 7009991
available on www.bresser.de
CLEANING AND MAINTENANCE
Before cleaning the device, disconnect it from the power supply (remove batteries)! Only use a dry cloth to clean the exterior of the device. To avoid damaging the electronics, do not use any cleaning fluid.
DISPOSAL
Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste disposal service or environmental authority for information on the proper disposal.
Do not dispose of electronic devices in the household garbage!
As per Directive 2012/19/EC of the European Parliament on waste electrical and
electronic equipment and its adaptation into German law, used electronic
devices must be collected separately and recycled in an environmentally
friendly manner.
In accordance with the regulations concerning batteries and rechargeable
batteries, disposing of them in normal household waste is explicitly
forbidden. Please make sure to dispose of your used batteries as required by
law — at a local collection point or in the retail market. Disposal in
domestic waste violates the Battery Directive.
Batteries that contain toxins are marked with a sign and a chemical symbol.
“Cd” = cadmium, “Hg” = mercury, “Pb” = lead.
EC DECLARATION OF CONFORMITY
Hereby, Bresser GmbH declares that the equipment type with part number:
7007402 is in compliance with Directive: 2014/53/EU. The full text of the EU
declaration of conformity is available at the following internet address:
http://www.bresser.de/download/7007402/CE/7007402_CE.pdf
WARRANTY & SERVICE
The guarantee period is 5 years and begins on the day of purchase. You can
consult the full guarantee terms as well as details of our services at
www.bresser.de/warranty_terms
Service
Please contact the service centre first for any questions regarding the
product or claims, preferably by e-mail.
e-mail: service@bresseruk.com
Telephone*: +44 1342 837 098
BRESSER UK Ltd
Bresser UK Ltd.
Suite G3, Eden House
Enterprise Way
Edenbridge, Kent TN8 6HF
United Kingdom
Number charged at local rates in the UK (the amount you will be charged per
phone call will depend on the tariff of your phone provider); calls from
abroad will involve higher costs.
www.bresser.de/start/bresser
References
- Bresser | Startseite | Expand Your Horizon mit BRESSER
- Bresser | Startseite | Expand Your Horizon mit BRESSER
- index · powered by h5ai 0.26.1 (http://larsjung.de/h5ai/)
- Bresser | BRESSER VentAir Thermo-/ Hygrometer mit Touchscreenfunktion und Lüftungsempfehlung | Expand Your Horizon
- Bresser | Social | Expand Your Horizon
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>