PLANET NMS-360V Renewable Energy Management Controller with LCD Touch Screen Installation Guide
- June 6, 2024
- PLANET
Table of Contents
- PLANET NMS-360V Renewable Energy Management Controller with LCD Touch
- Package Contents
- Hardware Description
- Physical Specifications
- Product Features
- Specifications
- Deployed Devices Monitored via NMS-360V Controller
- Wired Network Configuration
- Entering into the Web Management
- Setup Wizard
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PLANET NMS-360V Renewable Energy Management Controller with LCD Touch
Screen
Package Contents
Thank you for purchasing PLANET Universal Network Management Controller. PLANET NMS-360V comes in two sizes as described below:
- NMS-360V-12: Renewable Energy Management Controller with 12″ LCD Touch Screen
- NMS-360V-10: Renewable Energy Management Controller with 10″ LCD Touch Screen
Package Contents:
- The NMS-360V Controller x 1
- Quick Installation Guide x 1
- Adapter with Power Cord x 1
- Installation Kit x 1
If any item is found missing or damaged, contact your local reseller for replacement.
Hardware Description
Physical Specifications
Model | NMS-360V-10 | NMS-360V-12 |
---|---|---|
Dimensions (W x D x H) | 285 x 49 x 189 mm | 319 x 51.7 x 245 mm |
Weight | 2 kg | 2.9 kg |
NMS-360V-10 (10” Panel)
NMS-360V-12 (12” Panel)
VESA Mounting
The NMS-360V series is designed to be VESA-mounted as shown in the picture.
Just carefully place the LCD stand on the back of the controller and tighten
the given screws to secure the mounting.
Panel Mounting
There are eight holes located along the four sides of the NMS-360V. Insert the
clamp from the four sides and tighten them with the nuts provided.
Product Features
Network Devices Management
Dashboard| Providing the at-a-glance view of system, power, traffic,
and device event statuses.
---|---
Device List| Providing devices status overview and managed function.
Setup Wizard| Easy to use step-by-step guidance.
Node Discovery| Management is carried out once a BSP-360-powered device is
detected.
App-like Device Viewing| App-like devices that are compliant with SNMP, MQTT,
and Smart Discovery.
Event Table| The status of system can be reported via event alarm.
Alarm System| E-mail alerts for the administrator via the SMTP server.
Device Provisioning| Enabling BSP-360 to be configured and upgraded at the
same time.
Site Map| Real-time site map of BSP-360 and IP cams on the user-
defined map to optimize energy deployment.
Remote PoE control| Real-time remote PoE on/off to reboot connected devices.
User Control| Allowing on-demand account creation and user-defined
access policy.
Scalability| Free system upgrade and BSP-360 firmware bulk upgrade
capability.
Maximum Scalability| 1 site map, 512 nodes, 2048 managed IP cameras.
Network Management Characteristics
- Built-in DHCP Server
- Built-in RADIUS Server
- SSL secure access
- Web-based GUI management interface
- SNMP v1, v2c, and v3 management
- Supports PLANET DDNS/Easy DDNS
Specifications
Product
| NMS-360V-10| NMS-360V-12
---|---|---
Renewable Energy Management Controller with LCD Touch Screen
Platform
Form Factor| Panel Mount, VESA 100 x 100
Physical Specifications
I/O Interface
| 2 10/100/1000BASE-T Gigabit Ethernet RJ45 ports
2 USB 3.0 ports
(They cannot be used at the same time.)
1 Audio Line Out (reserved)
1 HDMI interface
2 DB-9 COM1,COM2 (reserved)
1 3-pin DC power input terminal
1 2-pin connector for power on/off button (reserved)
Storage| 2.5” 32G SATA3 HDD
Touch LCD Size| 10.1” TFT-LCD| 12.1” TFT-LCD
Touch Type| Resistive Touch Window Projected Capacitive Touch
Display Resolution| 1280 x 800| 1024 x 768
Display Luminance (cd/m²)| 350| 500
Display Viewing Angle (H°/V°)| 160(H) / 160(V)| 160(H) / 140(V)
Display Contrast| 800:1| 700:1
Display Backlight Lifetime (hrs)| 40,000 hrs| 30,000 hrs
Light Transmission (%)| Resistive Touch Window: over 80% Projected Capacitive
Touch: over 90%
Enclosure| Aluminum Die-casting Chassis
Power Requirements
| DC IN 9~36V
60W adapter 12V 5A with terminal block AC 100~240V, 2.0A, 60~50Hz.
Environment & Certification
IP Rating| IP66-rated front bezel
Temperature| Operating: 0 ~ 50 degrees C
Storage: -30 ~ 70 degrees C
Humidity| 10 ~ 90% relative humidity (non-condensing)
MTBF (Hours)| 100,000
Network Management
Number of Managed Devices| 512 BSP-360 units
Auto Discovery| Supports PLANET BSP-360
---|---
Dashboard| Providing the at-a-glance view of system, power,
traffic, system statistics and device event statuses
Device List| Providing devices status overview and managed function
Setup Wizard| Easy-to-use step-by-step guidance
Node Discovery| Management is carried out once a BSP-360-powered device is
detected
App-like Device Viewing| App-like devices that are compliant with SNMP, MQTT,
and Smart Discovery
Event Table| The status of system can be reported via event alarm
Alarm System| E-mail alerts for the administrator via the SMTP server
Device Provisioning| Enabling BSP-360 to be configured and upgraded at
the same time
Site Map| Real-time site map of BSP-360 and IP cams on the
user-defined map to optimize energy deployment
Remote PoE control| Real-time remote PoE on/off to reboot connected
devices
User Control| Allowing on-demand account creation and user-
defined access policy
Scalability| Free system upgrade and BSP-360 firmware bulk
upgrade capability
Backup/Restoration| Provides system and profile backup/restoration
Network Services
Network
| DDNS| Supports PLANET DDNS/Easy DDNS
DHCP| Built-in DHCP Server for auto IP assignment to APs
Management| Console; Telnet; SSL;Web browser (Chrome is recommended); SNMP v1,
v2c, v3
Discovery| Supports SNMP, ONVIF and PLANET Smart Discovery
Maintenance
| Backup| System backup and restore to local or USB HDD
Reboot| Provides system reboot manually or automatically per power schedule
Diagnostic| Provides IPv4/IPv6 ping and trace route
Standards Conformance
Regulatory Compliance| CE, FCC
Standards Compliance
| IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX
IEEE 802.3ab Gigabit 1000BASE-T
[Remarks] Only support BSP-360 V2 version.
Deployed Devices Monitored via NMS-360V Controller
Prior installation
The NMS-360V is used to centrally manage a large number of BSP-360s(V2).
Therefore, you need to upgrade the BSP-360(V2) firmware before using NMS-360V.
Please download and use the latest BSP-360(V2) firmware from the website so
that setting can be completed smoothly. The NMS-360V incorporated in a
workstation or PC can monitor the BSP-360s compliant with the MQTT Protocol,
SNMP Protocol, ONVIF Protocol and PLANET Smart Discovery utility. Follow the
steps below to set up the NMS-360V and BSP-360(V2) accordingly.
Step 1. Connect the devices, NMS-360V Controller and your computer, to
the same network.
Step 2. BSP-360: Log in to the Switch’s Web User Interface and enable the SNMP and NMS controller functions.
Wired Network Configuration
A computer with wired Ethernet connection is required for the first-time configuration of the NMS-360V Controller.
- Go to “Control Panel-> Network and Sharing Center-> Change Adapter Settings”.
- Double-click “Local Area Connection”.
- Select “Internet Protocol version 4 (TCP/IPv4)” and click “Properties”.
- Select “Use the following IP address” and then click the “OK” button twice to save the configuration. For example, the default IP address of the NMS-360V Controller is 192.168.1.100, then the manager PC should be set to 192.168.1.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
Entering into the Web Management
- Default IP Address: 192.168.1.100
- Default Management Port: 8888
- Default Username: admin
- Default Password: admin
Launch the Web browser (Google Chrome with seamless mode is recommended.) and enter the default IP address “https://192.168.1.100:8888”. Then, enter the default username and password shown above to log on to the system. * The secure login with SSL (HTTPS) prefix is required.
After logging on, connect the NMS-360V Controller to the managed network to centrally control PLANET managed devices.
Setup Wizard
- Account Modification: Set a new account and password for security
- IP Configuration Setting: Set the NMS-360V’s IP into the same local network segment.
- Devices Discovery: Search the managed devices and add to list. (Finish Wizard)
- If added devices are successful, you can see them in Device List / Management page.
Further Information
The above steps introduce the simple installations and configurations of the NMS-360V Controller. For further configurations of PLANET NMS, please refer to the user manual, which can be downloaded from the website. PLANET online FAQs: http://www.planet.com.tw/en/support/faq
Support team mail address: support@planet.com.tw
User’s Manual: https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword=N MS- 360V&view=3#list
If you have further questions, please contact the local dealer or distributor where you purchased this product.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>