metos PWD04 Water Dispenser Installation Guide
- June 6, 2024
- metos
Table of Contents
WATER DISPENSER
PROFF
WD, WD-E, WD-N, WD-EN, WD-2, WD-E2, WD-N2, WD-EN2, D-I WD ,D-I WD-E, D-I
WD-N, D-I WD-EN, D-I WD-2, D-I WD-E2, D-I WD-N2, D-I WD-EN2
Installation and Operation Manual
Translation of the original documentation
Rev. 3.4, Valid From: 1.2.2021, S/N 1096210201XXXX
(10.3.2022)
4213317, 4213319, 4213321, 4213323, 4213325, 4213327, 4213329, 4213331,
4213341, 4213342, 4213343, 4213344, 4319228, 4319230, 4319232, 4319234,
4319408,
4319410, 4319412, 4319414, 4309870, 4309872, 4309874, 4309876, 4309878,
4309880, 4309882, 4309884, 4309886, 4309888, 4309890, 4309892, 4309894,
4309896,
4309898, 4309899
General
Carefully read the instructions in this manual as they contain important
information regarding proper, effi client, and safe installation, use, and
maintenance of the appliance.
Keep this manual in a safe place for eventual use by other operators of the
appliance.
The installation of this appliance must be carried out in accordance with the
manufacturer’s instructions and following local regulations. The connection of
the appliance to the electric and water supply must be carried out by qualifi
ed persons only.
Persons using this appliance should be specifi cally trained in its operation.
Switch off the appliance in case of failure or malfunction. The periodical
function checks requested in the manual must be carried out according to the
instructions. Have the appliance serviced by a technically qualifi ed person
authorized by the manufacturer and using original spare parts?
Not complying with the above may put the safety of the appliance in danger.
Symbols used in the manual
This symbol informs about a situation where a safety risk might be at hand.
Given instructions are mandatory in order to prevent injury.
This symbol informs about the right way to perform in order to prevent bad
results, appliance damage or hazardous situations.
This symbol informs about recommendations and hints that help to get the best
performance out of the appliance.
This symbol explains the importance of careful and regular cleaning of the
machine to meet hygiene requirements.
Symbols used on the appliance
This symbol on a part informs about electrical terminals behind the part. The removal of the part must be carried out by qualifi ed persons only.
Checking the relationship of the appliance and the manual
The refrigerant in the appliance must fi rst be checked on the rating plate of
the appliance.
The rating plate of the appliance indicates the serial number of the
appliance. If the manuals are missing,
it is possible to order new ones from the manufacturer or the local
representative. When ordering new manuals it is essential to quote the serial
number shown on the rating plate.
Safety
Safe use of the appliance
The appliance must be connected to an earthed socket.
When moving or servicing the appliance, always unplug it from the power
supply.
WARNING
The refrigerant and charge are declared on the rating plate. Refrigerant R290
(propane) is highly fl amiable. Handle equipment that contains R290 with extra
care.
Under no circumstances should the value set at the factory of the
refrigeration unit be set colder. Changing the setpoint can cause the
refrigeration unit to freeze and the actuators connected to it, such as the
taps, to break. At worst, water damage can result. ”
Modifying the equipment without the approval of the manufacturer invalidates
the manufacturer’s product liability.
Dangerous situations may arise if the given instructions are not followed.
The manufacturer declines all responsibility for any operations carried out on
the appliance without following the instructions in this manual.
Disposal of the appliance
The appliance contains parts and components, the disposal of which requires
special treatment.
Contact local authorities to obtain instructions on how to dispose of the
appliance.
Functional description
Intended use of the appliance
The appliance is intented for cooling and dispensing drinking water.
Structure and operating principle
WD, WD-E, WD-N, WD-EN, WD-2, WD-E2, WD-N2, WD-EN2 are free-standing models and
designed to be situated in a serving line.
Models D-I WD, D-I WD-E, D-I WD-N, D-I WD-EN, D-I WD-2, D-I WD-E2, D-I WD-N2,
D-I WD-EN2 are delivered without an outer casing and are designed for
insertion into a line structure.
The top has a faucet and a basin with a drain for drip water.
Electronic faucet (models PWD-04A-E, PWD-04A-EN, D-I WD-E, D-I WD-EN)
The faucet is turned on and off by means of a solenoid valve actuated by a
photocell.
When a glass is held within the photos ll’s sensing range, the solenoid valve
opens and water starts to fl ow. The faucet turns off automatically after the
adjusted fl ow period. The faucet works best with fl at-bottomed glass.
Operating instructions
Operation
Mechanical faucet: Push the lever with a glass.
Electronic faucet: Hold a glass under the faucet.
4.2. After operation
4.2.1. Cleaning the exterior surfaces
Clean the stainless steel surfaces with neutral, liquid detergents.
Abrasive or corrosive agents must not be used.
Cleaning the condenser (to be performed by a service technician)
Disconnect the appliance from the power supply before cleaning the condenser.
Depending on circumstances, the condenser should be cleaned once a year or
more often, if necessary.
Condenser clogging is apparent when compressor running times get longer, the
cooling effect decreases, and the condensing temperature rises. Finally,
condenser clogging can damage the compressor.
When cleaning the condenser with a brush, be careful not to damage the
condenser. The condenser can also be cleaned using a vacuum cleaner.
Replacing the fi later (option) (to be performed by a service technician)
If the appliance is supplied with an optional fi later, we recommend replacing it at the intervals of 4800 liters or once the fi filter is clogged. The fi lter is clogged when the water output starts to decrease and the water fl ow becomes weaker. Depending on the frequency of use, the fi filter should be replaced approximately every six months.
Cut off the incoming water and run water from the faucet to release the pressure. Screw the cover (3) off the holder (1). Remove the old fi lter (2). Insert a new fi lter inside the cover and screw the cover (3) to the holder (1).
Installation
General
The appliance is designed to function in locations with temperatures of 10°C
to 35°C.
The appliance must not be installed close to appliances that generate heat,
e.g. ranges.
If the water pressure at the installation site exceeds 5 bar, the device’s
water connection must be equipped with a pressure reducing valve
Storage
The appliance should be stored in a dry place, at a temperature over +1°C. If
the appliance has been exposed to temperatures below 0°C, it must be drained
(allowed to melt). After melting, before taking the appliance into use, make
sure that there is no damage to or leakage in piping.
Electronic faucet: It is essential to take care that water in the faucet and
solenoid valve does not freeze.
Unpacking the appliance
The appliance should be transported to the installation site in its transport
package. Do not remove packing until just before installation to prevent dust
in the installation place from damaging the appliance.
The appliance should be stored and transported in an upright position.
Installation
The appliance should be placed in a well-ventilated room. Avoid placing the
appliance in direct sunlight.
The appliance must be installed in a vertical position with an accuracy of
±3°. Greater skewness may cause malfunctions.
When installing D-I models care must be taken that the machinery is not
positioned directly on the fl oor, but an air gap of at least 10 cm is left
between the machinery and the fl oor. This is to make sure that water, possibly
dripping onto the fl oor, would not damage the electrical components of the
machinery and cause hazardous situations.
The compressor is equipped with damping of vibrations, but in some cases,
vibrations can transfer to other structures. A rubber mat placed under the
appliance can absorb vibrations and noise (needed in special cases only).
The thermostat has been set at the factory for ordinary operating
circumstances.
When installing refrigerated D-I models, special attention must be paid to
condenser air circulation.
Make sure that the condenser air inlet is not blocked and that warm air can
freely exit the compressor compartment. The temperature of inlet air is of
crucial importance to the cooling effect of the appliance.
Ensure suffi cient air inlet/air circulation for the condenser.
Condenser air circulation
Do not mount the condenser on a closed plinth, as this will prevent condenser
air circulation. Air venting takes place below the appliance and air intake at
the front. Do not block the condenser air inlets.
Opening for the drip basin (D-I models)
An opening must be made for the drip basin on the table top. The water cooler is installed inside the counter. The necessary openings are marked on the pictures with solid lines and the shape of the drip basin with broken lines.
Make a water connection between the faucet and the water cooler. Installation sequence:
- Assemble the faucet
- Attach the faucet to the drip basin
- Attach the pipe connector to the faucet
- Attach the pipe connector to the machinery outlet
- Connect the faucet and the machinery outlet with a CU-pipe Ø 10 mm (not included in delivery)
Connect the water cooler only to a cold water supply. A pressure reducer is
needed if the water supply pressure is above 5 bar. The connection of the
appliance to the water supply must be carried out by qualifi ed persons only.
NOTE. Do not remove the spacer ring of the electronic faucet during
installation!
Electrical connections
The appliance is designed to function in the electrical power network 1/N/PE
AC 230V 50Hz. Connect the
appliance to the power supply with an earthed socket.
First startup
The water tank of the cooler has to be fi billed before startup.
Note that the water tank has to be fi called manually, it does not fi ll even
though the cooler is connected to the water supply.
Fill the tank through the pipe located behind the front panel. Check the water
level on the pipe. The tank volume i approx. 9 liters.
Adjusting the glass fi lling rate (mechanical faucet)
Water fi lling rate can be adjusted with the help of a screw (1) located on top
of the faucet by turning the screw with a screwdriver.
If, after installation, some air comes out of the faucet, allow water to run
until no air is coming and the water is clear.
Adjusting the electronic faucet for the glass used
To be performed by an authorized service technician or installer.
Adjusting the water fl ow (electronic faucet)
To be performed by an authorized service technician or installer.
Troubleshooting
In case the appliance does not function as expected, review the following list of problems to fi nd out if the appliance can be put in order without a service call. In this way you can avoid unnecessary service calls and costs. In all inquiries, please contact the nearest Metos service. Most problems can be managed on the phone.
PROBLEM | POSSIBLE CAUSE | ACTION |
---|---|---|
No water comes out of the faucet | Waterline obstructed (faucet is | |
closed) | Open the faucet | |
Not enough water in the tank | Check and fill | |
Too little water coming | Filter (option) clogged (water flow gradually | |
decreases) | Replace the filter |
Water flow adjusted to a too low
flow rate| Adjust the flow rate correctly
Too much water coming| Water flow wrongly adjusted| Adjust the flow rate
correctly.
Water is warm| The power cable is not properly plugged in the socket| Put the
cable properly in the socket
Defective fuse| Replace the fuse
Condenser covered by dust| Clean the condenser
Defective thermostat| Call the service
Defective compressor| Call the service
The cooler is installed in a too warm environment or otherwise not a suitable
location| Call the service
The appliance does not contain parts that can be serviced by the user. Service must be carried out by an authorized service company.
Technical specifi cations
Refrigeration circuit diagram
Connection diagram S00354 A3 (Mechanical faucet)
Connection diagram S00196 A2 (Electronic faucet)
Dimensions, machinery
Installation drawing Refrigeration circuit diagram
Connection diagram S00354 A3
Connection diagram S00196 A2
Dimensions, machinery
ITEM | TYPE | SPECIFICATION |
---|---|---|
Electric connection | Cooling and electronic | 1/N/PE AC 230V 50Hz |
Power input | Cooling and electronic | 0,16 kW |
Extraction capacity | Cooling | 180 W, +7°/54° |
Exterior | Cooling | R290 |
Ulkovuoraus | All | Stainless steel |
Control unit | Cooling | Thermostat |
Capacity | 40 litres / hour | |
Drain | Floor drain | |
Water connection | Cold water, max. 5 bar | |
Sensing range | _ Electronic | _ preset, range 0-40 cm |
Rev. PED 5.7 17.10.2017
EC DECLARATION OF CONFORMITY
Manufacturer’s name
METOS OY AB
Address 04220 KERAVA FINLAND
Declare that the following product
Name, type, or model
Corona Drop-in is in conformity with the relevant provisions of the following
directives
MD 2006/42/EC, LVD 2014/35/EU, EMC 2014/30/EU, RoHS 2011/65/EC. WEEE
2012/19/EU, ATEX 2014/34/EU
and furthermore declares that the following harmonized standards (or
parts/clauses) have been used
EN 61000-6-3: 2007
EN 61000-6-1: 2016
EN ISO 12100:2010
EN 60079-15:2019
and furthermore, we declare that the following other standards (or
parts/clauses) have been used
EN 60204-1: 2018
Product design examination certificate and the notified body supervising the
quality system (only pressure vessels)
The person mentioned below is authorized to compile the technical file
Risto Koskelainen
Metos Oy Ab, Ahjonkaarre, 04220 Kerava, Finland
This declaration of conformity is issued under the sole responsibility of the
manufacturer. The object of the declaration described above is in conformity
with the relevant Union harmonization le•islation Place and date of issue
KERAVA 14.02.2022
Original
Documents / Resources
|
metos PWD04 Water
Dispenser
[pdf] Installation Guide
PWD04, Water Dispenser, PWD04 Water Dispenser
---|---
|
metos PWD04 Water
Dispenser
[pdf] Installation Guide
PWD04, Water Dispenser, PWD04 Water Dispenser
Read User Manual Online (PDF format)