Carefully read the instructions in this manual as they contain important information regarding proper, efficient and safe installation, use and maintenance of the appliance. Keep this manual in a safe place for eventual use by other operators of the appliance

The installation of this appliance must be carried out in accordance with the manufacturer’s instructions and following local regulations. The connection of the appliance to the electric supply must be carried out by qualified persons only.

Persons using this appliance should be specifically trained in its operation.

Switch off the appliance in case of failure or malfunction. The periodical function checks requested in the manual must be carried out according to the instructions. Have the appliance serviced by a technically qualified person authorized by the manufacturer and using original spare parts.

Not complying with the above may put the safety of the appliance in danger.

Symbols used in the manual

 This symbol informs about a situation where a safety risk might be at hand. Given instructions are mandaSTOP tory in order to prevent injury.

 This symbol informs about the right way to perform in order to prevent bad results, appliance damage or hazardous situations.

 This symbol informs about recommendations and hints that help to get the best performance out of the appliance.

Symbols used on the appliance

 This symbol on a part informs about electrical terminals behind the part. The removal of the part must be carried out by qualified persons only.

Checking the relationship of the appliance and the manual

The rating plate of the appliance indicates the serial number of the appliance. If the manuals are missing, it is possible to order new ones from the manufacturer or the local representative. When ordering new manuals it is essential to quote the serial number shown on the rating plate.

Safety

Safe use of the appliance

 For safe use of the appliance, observe the following safety instructions:

  • When moving or servicing the appliance, always unplug it from the power supply.
  • While cleaning the appliance, be cautious not to allow the electrical devices to come into contact with water. Spraying water in the immediate vicinity of the appliance is forbidden.
  • Exposing the appliance to rain is forbidden.

If the appliance is not used for a long time, it should be unplugged from the power supply, cleaned and wiped dry on the inside.

Disposal of the appliance

The appliance contains parts and components, the disposal of which requires special treatment. Contact local authorities to obtain instructions on how to dispose the appliance.

WARNING
The refrigerant and charge is declared on the rating plate. Refrigerant R290 (propane) is highly flammable. Handle equipment that contains R290 with extra care.

 Modifying the equipment without the approval of the manufacturer invalidates the manufacturer’s product liability.

Functional description

Intended use of the appliance

The appliance is intended for short-time storage and distribution of foodstuffs in dining rooms and restaurants.

 The manufacturer shall not be held liable for situations which may arise from failure to comply with the warnings and instructions given in this manual.

Use for other purposes

 Use of the appliance for any other purposes is prohibited.
 Consult the manufacturer in case you intend to use the appliance for other purposes than stated above.

Functional description

The cold basin and frost plane are equipped with a refrigeration unit.
The crushed ice basin is insulated, but it does not include a refrigeration unit.

Operating switches

Cold basin and frost plane

  1. Main switch
  2. Thermostat
  3. Condenser

Operating instructions

Operation
Cold basin CB and frost plane FrP

Before placing products in the unit, wait until it has reached the temperature set with the thermostat.

Correct cold storage of foodstuffs facilitates kitchen activities and affects energy consumption:

  • Do not load products until the appliance has reached the correct operating temperature.
  • Monitor the internal temperature of the unit daily.
  • Always keep the products in good order.
  • Do not store spoiled food in the unit.

In normal conditions, the thermostat need not be adjusted.

Crushed ice basin CIB

Before loading the products, put crushed ice or cold bed in the basin. Points to be observed in use:

  • Position the product as close as possible to the cold source, preferably in direct contact with it.
  • The basin’s insulation extends the working life of crushed ice, but you should watch the melting of ice during operation and add ice as needed. · The basin can be used even without a cold source, however, not for foodstuffs that require cold storage.
  • Place crushed ice/cold bed in the basin as near as possible the serving time.

After use

Emptying the basin

Nova and drop-in units have a drain valve beneath the basin. Water can be emptied by opening this valve.

If the unit has not been connected to the sewer system, it is extremely important to keep the drain valve tap closed at all times except during emptying, particularly when the unit has been installed on a watersensitive floor surface, such as parquet.

Cleaning

In normal use, the appliance does not require any other daily care than sufficient cleaning.

For cleaning the interior and exterior, use neutral or slightly alkaline cleaning agents or wipe the surfaces with a damp cloth. Abrasive materials should not be used.

 Use of a hose for cleaning the appliance is forbidden.

Clean the condenser once a week.The machinery does not normally require any other cleaning. Vacuumclean the condensing unit using a plastic nozzle to avoid damaging the condenser.

 Before vacuum-cleaning the condenser, switch off the appliance at the mains by unplugging the electric cable from the socket.

 Other cleaning procedures except the condenser cleaning should be carried out by an authorized service workshop.

 It is recommended to have the compressor cassette cleaned inside by a service company 1-2 times a year.

Installation

Operating conditions

The appliance is designed for operation at temperatures of +10°C to + 25°C.
The appliance should not be placed close to bain-maries or ovens.

Transport and storage

The appliance should be transported to the installation site in its transport package. Do not remove package until in the immediate vicinity of the installation place. The appliance should be transported in an upright position.

The appliance is made of polished stainless steel and of plastic, so it can become scratched very easily in site conditions. Therefore, the appliance should be delivered to the installation site at a later stage of construction work. It is forbidden to use the appliance as an installation base.

 The appliance should not be stored outdoors, not even in its transport package.

Cold basin and frost plane

 In case the appliance has been stored in a non-heated location so that its temperature and particularly the temperature of the machinery has fallen below 0°C, the appliance should be kept in room temperature until the machinery temperature is at least 10°C. Starting the cold machinery may damage the compressor.

 In case the appliance has been heavily tilted just before the intended start- up, you should wait about 30 minutes before switching the appliance on. Otherwise the oil accumulated in the suction inlets of the compressor may damage the compressor with a hydraulic shock.

Unpacking the appliance

Remove foils protecting the stainless steel and plastic surfaces cautiously to prevent the surfaces from getting scratched.

Installation of Nova units

If the unit is fitted with wheels, it must be installed on a level surface. When the unit is in its correct place, the wheels must be locked to point away from the center of the unit. If the unit is fitted with legs, these can be adjusted so that the unit stands steadily on an uneven surface as well.

If a serving line is composed of several units, they can be linked together from under the tray slides with the help of gray Nova connectors delivered with the unit.

Electrical connections

Connect the appliance to the power supply with an earthed socket. For making the connection, a socket protected with a fuse of max. 16 A has to be provided for each unit.

Start-up

Cold basin and frost plane

After connecting the appliance to the power supply, turn on the main switch (green) and make sure that the indicator light of the switch lights up. In case you have problems with taking the appliance into use, contact the Metos service.

Troubleshooting

In case the appliance does not function as expected, review the following list of problems to find out if the appliance can be put in order without a service call. In all enquiries, please contact the nearest Metos service. Most problems can be managed on the phone.

PROBLEM POSSIBLE CAUSE ACTION
The appliance does not start even if the main switch is turned on. Electrical
cable is not properly plugged in the socket. Put the cable properly in the

socket.
Defective fuse.| Replace the fuse.
Cold basin and frost plane: The compressor is running, but the temperature does not fall to the set value.| Condenser is covered by dust.| Vacuum-clean the condenser.
Ambient temperature exceeds the maximum value (+25°C).| Make sure that the appliance has not been placed close to a heat source. If necessary, pro- vide mechanical ventilation.
Prevented air circulation beside the condenser.| Remove obstacles to ensure free air circulation.

 The appliance does not contain parts that can be serviced by the user. Service must be carried out by an authorised service company

Dimensions

Item Model Specificati- on
Dimensions (mm) 450 A 465
800 A 800
1200 A 1200
1600 A 1600
B 650

C 1150
D 900 (normal), 750 (low)
E 1280 (normal), 1130 (low)

Connection Diagram

Item Model Specificati- on
Electrical connection 230 V 1~ 300W 10A
Refrigerant CB,FrP R290
Insulation material CB,FrP,CIB Foamed polystyrene
Styrenhet Control unit CB,FrP Thermostat
Drain connection 3/4” Outer thread