KESSEL Aqualift S 100 Lifting Stations for Wastewater without Sewage Instructions
- June 3, 2024
- KESSEL
Table of Contents
- KESSEL Aqualift S 100 Lifting Stations for Wastewater without Sewage
- The lifting stations for private and commercial use.
- Aqualift S 100 and S 200 lifting stations
- Areas of application
- Aqualift S 100 and S 200 for private use
- Version:
- Tank:
- Tank:
- Coverage features:
- Pump:
- Note:
- Pumping capacity
- Lifting station Aqualift S 100 Mono/Duo Tronic
- Version:
- Dimensions:
- Tank:
- Pump:
- Comfort control unit:
- Lifting station Aqualift S 200 Duo Tronic for free-standing installation
- Version:
- Dimensions:
- This is KESSEL
- Leading in drainage.
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KESSEL Aqualift S 100 Lifting Stations for Wastewater without Sewage
Instructions
The lifting stations for private and commercial use.
Aqualift S 100 and S 200 lifting stations
Areas of application
Aqualift S 100 and S 200 for commercial use
Aqualift S 100 or S 200 as Duo system with Tronic control unit, free-standing set-up after grease separators for the disposal of kitchen wastewater.
Aqualift S 100 and S 200 for private use
Aqualift S 200 – free-standing set-up for complete drainage of basement wastewater, such as wastewater from washing machines, sinks or showers.
The compact dimensions of the tanks allow the Aqualift S 100 and Aqualift S 200 to be installed in existing sump openings.
Lifting station Aqualift S 100 Mono for free-standing installation and
wastewater without sewage
Lifting station for faecal-free wastewater, free-standing set-up, preassembled for final installation on site.
- With odour-tight cover and quick-release closure for easy maintenance
- Tank made of PE, resistant to aggressive wastewater
- Including backflow preventer for the pressure pipe
- Including socket Ø 110 mm for inlet and sampling
- Pump/s with multi-vane impeller for maximum operating reliability
Version:
Type of system: Single station / Pump control: Float switch / Backflow
preventer: integrated /
Installation situation: free-standing set-up / Type of wastewater: wastewater
without sewage
General characteristics:
Colour: black / Standard: EN 12050-2
Dimensions: Length: 670 mm / Width: 530 mm / Height: 650 mm
Tank:
Inlet nominal size (Ø): 110 mm / Tank volume: 120 l / Pressure pipe connection
(Ø): 63 mm /
Pumping volume: 25 l
Coverage features:
Cover material: Polymer / Colour of cover: violet /
Tightness: odour-tight / Locking: Quick-release closure
Free passage: 10 mm
Tank:
Inlet nominal size (Ø): 110 mm / Tank volume: 120 l /
Pressure pipe connection (Ø): 63 mm /
Pumping volume: 25 l
Coverage features:
Cover material: Polymer / Colour of cover: violet /
Tightness: odour-tight / Locking: Quick-release closure
Free passage: 10 mm
Pump:
Type of fuse required (electrical protection): C 16 A /
Max. temperature (permanent) of conveyed material: 40 °C / Connection type:
Schuko (earthed contact) 2-pin / Length of mains cable for pump: 5 m /
Protection class (pump): IP 68 (3 m) /
Type of pump connection cable: H07RN-F 3G 1.0 mm2
Note:
Pumps available as resistant versions on request:
individual @kessel.de ↗ Accessories: page 9
Pumping capacity
Lifting station Aqualift S 100 Mono/Duo Tronic
for free-standing installation and wastewater without sewage
Lifting station for faecal-free wastewater, free-standing set-up, preassembled for final installation on site.
- With odour-tight cover and quick-release closure for easy maintenance
- Tank made of PE, resistant to aggressive wastewater
- Including backflow preventer for the pressure pipe
- Including socket Ø 110 mm for inlet and sampling
- Pump/s with multi-vane impeller for maximum operating reliability
Version:
Type of system: Single or twin station / Pump control: Control unit / Backflow
preventer: integrated /
Installation situation: free-standing set-up / Type of wastewater: wastewater
without sewage
General characteristics:
Colour: black / Standard: EN 12050-2
Dimensions:
Length: 670 mm / Width: 530 mm / Height: 650 mm
Tank:
Inlet nominal size (Ø): 110 mm / Tank volume: 120 l / Pressure pipe connection
(Ø): 63 mm /
Pumping volume: 50 l
Coverage features:
Cover material: Polymer / Colour of cover: violet /
Tightness: odour-tight / Locking: Quick-release closure
Free passage: 10 mm
Pump:
Type of fuse required (electrical protection): C 16 A /
Max. temperature (permanent) of conveyed material: 40 °C / Connection type:
coded plug / Length of mains cable for pump: 5 m / Protection class (pump):
IP 68 (3 m) / Type of pump connection cable: H07RN-F 3G 1.0 mm2
Comfort control unit:
: Self-diagnosis system (SDS), battery buffering, multi-line digital display,
log book function,
USB interface, GSM interface / Potential-free contact: optional / Protection
class control unit: IP 54 / Length of mains cable for control unit: 1.4 m /
Type of level
measurement: pneumatic / Alarm sensor: Immersion pipe
Note: Pumps available as resistant versions on request: individual @kessel.de
↗ Accessories: page 9
Lifting station Aqualift S 200 Duo Tronic for free-standing installation
and wastewater without sewage
Lifting station for faecal-free wastewater, free-standing set-up, preassembled for final installation on site.
- With odour-tight cover and quick-release closure for easy maintenance
- Tank made of PE, resistant to aggressive wastewater
- Including backflow preventer for the pressure pipe
- Including socket Ø 110 mm for inlet and sampling
- Pump/s with multi-vane impeller for maximum operating reliability
Version:
Type of system: Single or twin station / Pump control:
Control unit / Backflow preventer: integrated /
Installation situation: free-standing set-up / Type of wastewater: wastewater
without sewage
General characteristics:
Colour: black / Standard: EN 12050-2
Dimensions:
Length: 670 mm / Width: 655 mm / Height: 815 mm Tank:
Inlet nominal size (Ø): 110 mm / Tank volume:
220 l / Pressure pipe connection (Ø): 63 mm /
Pumping volume: 100 l
This is KESSEL
Since 1963, KESSEL has stood like no other company for innovative and reliable
drainage technology. We have established ourselves as the impulse generator in
the
industry and are now a worldwide premium supplier.
During the production of our products as well as their operation on-site, we
keep quality assurance, environmental protection and worker’s safety at the
top of our list.
We also place great value in the relationship with our customer, providing
consultation, installation support, commissioning and after-sales service.
One thing is certain, our innovation, quality, reliability and service is
number one in the industry.
KESSEL–Leading in drainage
Leading in drainage.
No matter whether the task involves discharging water, wastewater treatment or
backwater protection:
if the best solution is required, there is no option but KESSEL.
Backwater protection
Pump technology
Separator technology
Drainage technology
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>