VPro BR MAX SERIES Ball Valve Instruction Manual

June 3, 2024
VPro

All manuals and user guides at all-guides.com
Instruction manual
MAX SERIES Ball Valve BR BS VR TR LR T3 L3
OSYBR20A-EN
SP-1408

Please read this manual before installation and use.

GENERAL

This series is suitable for main or bypass valve in piping system.
The position of manual handle can be changed.

Manual operation
Valve only
Lever
Gear

Valve
BR type For various fluids and general use.
BS type For Wafer.
TR / LR type For mixing / dividing.
T3 type Trunnion structure. (with flow paths)
L3 type Trunnion structure.

PRODUCT CODE

(1) Actuator MAX
(2) Valve BR BS VR TR LR T3 L3
(3) Operation 0 : (Zero) Valve only L : With manual lever G : Gear
(4) Sizing code – : Hyphen
(5) Connection 1 : JIS 10K 3 : JIS 20K| (6) Body material T : SCS13A U : SCS14A
(7) Ball material T : SUS304 / SCS13A U : SUS316 /  SCS14A
(8) Seat material F : F-PTFE G : R-PTFE R : R-F-PTFE
P : R-PTFE
(9) Size [mm] ex. 25 A 025
(10) Option ST : Seat for abnormal pressure rise
(11) Flow paths a to d : T3 type
---|---

VALVES SPECIFICATIONS

Water Oil Air, Gas Steam Chemicals Sea water Slurry Negative pressure

BR BS VR type

Valve type BR BS VR
Design 2-way, Full port 2-way, Wafer 2-way, V-port
Connection JIS1OK Flanged-end JIS2OK Flanged-end JIS Flanges 10K

Flanged-end
Fluid| | |
Max pressure| 1 MPa| 2 MPa| 1 MPa| 1 MPa
Size [mm]| 015 to 100| 015 to 150| 015 to 080| 015 to 150| 015 to 080
Material| Body| SCS14A| SCS13A| SCS13A| SCS13A| SCS14A| SCS14A
Ball| SCS14A| SCS13A| SCS13A| SCS13A| SCS14A| SUS316 / SCS14A
Seat| F-PTFE R-PTFE
R-F-PTFE| F-PTFE R-PTFE
R-F-PTFE| R-PTFE R-F-PTFE
Stem seal| Packing| R-PTFE| R-PTFE| R-PTFE
0-ring| FKM| FKM| FKM

The optional for steam fluids.

Valve type Option code 0-ring
BR BS VR ST Replace (Steam resistant FKM)

PRESSURE & TEMPERATURE RATING

Note) Insulation options are required for use with fluids more than 150 °C.

INHERENT FLOW CHARACTERISTIC

Water Oil Air, Gas Steam Chemicals Sea water Slurry Negative pressure

TR LR T3 L3 type

Valve type TR / LR T3 / L3
Design 3-way, Full port 3-way, Full port
Connection JIS1OK Flanged-end JIS1OK Flanged-end
Fluid
Max pressure 1 MPa 1 MPa
Size [mm] 020 to 040 050 to 100
Material Body SCS13A
Ball SUS304 SCS13A
Seat R-PTFE R-PTFE
Stem seal Packing R-PTFE
0-ring FKM

The optional for steam fluids.

Valve type Option code 0-ring
TR LR ST Replace
T3 L3 ST-VF Add

O-ring: Steam resistant FKM

PRESSURE & TEMPERATURE RATING

Note) Insulation options are required for use with fluids more than 150 °C. (T3 / L3: 170 °C)

INHERENT FLOW CHARACTERISTIC (TR / LR)

INHERENT FLOW CHARACTERISTIC (L3)

FLOW PATHS (Position 1 / P1) (Position 2 / P2)

Note) When a closed path is exposed to high pressure, it may leak slightly to an open path. (TR / LR)

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

LEVER AND GEAR DIMENSIONS

1 CASTING LEVER

Valve size [mm] Lever Hex bolt
BS BR

VR
TR
LR
L3| T3| L| H| A
015
to
020| 015
to
020| –| 115| 36| 9| M5×15
025
to
032| 025
to
032| 025| 145| 46| 11| M5x15
040
to
050| 040
to
050| 040| 220| 52| 14| M6×15
065
to
100| 065
to
080| 050
to
065| 320| 55| 17| M8×15
125
to
150| 100
to
125| 080
to
100| 430| 60| 22| M10×20

2 PIPE LEVER

Valve size [mm] Lever Knob bolt
BR L3 T3 L
150 125 to 150 750

HANDLING OF MANUAL LEVER

  1. Attention
    • The lever handle is removed and shipped.
    • The lever mounting direction can be changed in units of 45 degrees.
    • Do not apply excessive torque to the lever.
    • Do not strike or extend the lever with a tool.
    • The arrow on the plate indicates the direction of flow.

  2. LEVER HANDLE INSTALLATION (Casting lever)
    • Plate of position indicator is attached on the valve by C-type snap ring. Install the manual lever on it tightening the bolt.
    • The position of manual lever can be changed according to piping circumstances.

  3. LEVER HANDLE INSTALLATION (Pipe lever)
    • Remove the bolt and nut from the lever.
    • Loosen the knob bolt. Insert the lever into the connector.
    • Tighten the bolts so that the lever does not fall off.
    • Fix the lever with the knob bolt.

GEAR DIMENSIONS

Valve size [mm] K Actuator
BS BR VR TR LR L3 T3
065 065 050
to to to
100 080 065
125 100 080
to to to
150 125 100
150 125
to 150 Φ300 MAG-F12

HANDLING OF GEAR

  • The handle wheel of the gear is removed and shipped.
  • Insert the handle into the gear shaft.
  • Insert a pin into the hole in the handle.

HANDLING & STORAGE

  1. HANDLING
    Proper care in handling the valve should be taken to prevent damage. Do not drop or throw it.

  2. STORAGE
    Store the valve in the protected area from dust, moisture, and direct sunlight. If possible, should be kept in the original packaging.

  3. CHECKING
    • Check the product code before installation.
    • Confirm that there is no screw loose or part deformation.

INSTALLATION

  1. PRECAUTIONS
    Before installing, clean pipe and valve ends.
    Make sure they are free of dirt, dust and etc.

  2. PIPING FLANGES
    • VR type has a flow direction. Install the valve accordingly.
    • Specify the ST option if a steam fluid. Flow direction is restricted by ST option. (BR / BS)
    • Gasket should be selected appropriately to suit the fluid, pressure and temperature.
    Use spring washer to prevent from decreasing surface pressure gasket when the temperature change happens frequently.
    • Tighten all bolts using crossover method to load the joint evenly.
    • Wafer type ball valve is put between two seats of flanged-end and tightened with long bolts. (BS)
    • In the TR / LR type, when the flow path is subjected to a high pressure from arrow, it may leak slightly to the low pressure port.

  3. ENVIRONMENT
    If there is a possibility that the fluid and drive part freeze, please take measures to prevent freezing.

  4. POSITIONING
    Should be positioned through 90° upward from horizontal. Provide space around the product to allow manual operation, inspection and replacement work.

  5. CAUTIONS FOR MAINTENANCE (T3 / L3)
    Do not keep warm for maintenance of the valve gland.

TIGHTEN THE GLAND NUTS (T3 / L3)

  • Check that there is no leakage from the gland packing.
  • If it leakage, tighten gland nuts by alternately.
    Do not over-tighten the gland nuts.

Recommended torques [N• m]

Valve size [mm]| Torque
T3| L3
25| 025| 3.5
40| 040 to 050| 7
050 to 065| 065 to 080| 10
080 to 100| 100 to 125| 14
125 to 150| 150| 20

MAINTENANCE

Do the routine maintenance at least once in half a year.
Inspection items

  • Confirm operation of opening and closing.
  • Confirm whether screws are loose or not.
  • Confirm the fluid temperature or pressure.
  • Confirm the leak from valve stem.
  • Confirm the bolt tightening torque.

TROUBLESHOOTING

Problem Cause Solution
Stop in the mid position. • Biting of valve seat.
• The scale has adhered to the valve ball. Remove a foreign object.
Leakage from valve body • Valve cap get loose.
• Valve body is damaged. Replace the valve.
Leakage from valve seat Seat is worn
or damaged. Replace the valve. Replace the seat.
Leakage from valve stem Stem packing is worn or distorted. Replace the

valve. Replace the packing.
Leakage from
valve gland (T3 / L3)| Gland packing is worn or distorted.| Tighten the gland nut.
Replace the gland packing.

For more information contact
NIPPON VALVE CONTROLS, INC. for consultation.

Document is subject to change without notice.
1-21-19 Meieki minami, Nakamura-ku, Nagoya 450-0003 JAPAN