MOUNT THE PANEL

If mounting on a wall use anchors that are designed to support at least 15 lbs. (6.8 kg), according to the anchor manufacturer’s specifications. If mounting to an AutoJet® system use provided hardware. The mounting holes are on 5.44″ (138 mm) x 10.72″ (272 mm) centers and are made for 1/4″ (6 mm) screws with 3/8″ (10 mm) diameter screw heads.

CONNECT ELECTRIC SPRAY NOZZLES

Connect spray nozzle cable to the Main connection. For multiple nozzles, connect nozzles to a junction block and then connect the junction block cable to a Main connection. (Connect up to 10 electric spray nozzles using the junction block)
For additional connections see step 3

ADDITIONAL CONNECTIONS IF APPLICABLE

REMOTE DUTY CYCLE
Connect Remote Duty Cycle cable to 4-20mA connection on the panel. Once the unit is powered up on the HMI you can set the duty cycle with a 4-20mA signal to control the spray nozzles cycle speed.

TRIGGER OR SENSOR
Connect cable to Trig connection that will be used to start spray sequence. Available triggers are as follows, the one used should be basedon the customer’s application.

  • Trigger cable (for use with customer-supplied trigger signal)
  • Sensors including:
    • Object
    • Proximity
    • Laser (short/long)
    • Thru-beam
    • Full-spectrum color sensor
  • Hand-held trigger unit
  • Footswitch

AUX = NOZZLE AIR ON/OFF
The Aux/Nozzle Air electrical connection is used to actu-ate the air solenoids in our air control panel. Connect the cable from the air control panel to Aux/Nozzle Air connec-tion on the panel.

TRIGGER INTERLOCK
Trigger Interlock controls the state of run/standby
mode. Connect the trigger interlock cable to the
T. int. connection on the panel.

POWER UP THE PANEL

AutoJet 1750+ Spray Control Panel fig
6

Plug into grounded 100/240VAC, 3A, single-phase outlet. Turn power on. HMI display will illuminate.
To set spray parameters and for HMI operation, please refer to the Application Settings in the owner’s manual.

DOWNLOAD THE SMART DEVICE CONNECTION

  1. Go to the Google® Play Store or Apple® App store and download a VNC viewer app, such as VNC® Viewer from RealVNC®.

  2. In Wi-Fi settings on your mobile device, locate the Wi-Fi SSID, typically SSCO_xxxxxx. Select connect and enter the default password of SSCO1750.
    Note: There is a chance that your network administrator blocks this type of connection.

  3. Open VNC Viewer and connect to the 1750+ at: 192.168.0.20:5900.

North Avenue and Schmale Road, P.O. Box 7900, Wheaton, IL 60187-7901 USA
Tel: 1.800.95.SPRAY Fax: 1.888.95.SPRAY Email: info@spray.com
www.spray.com

Intl. Tel: 1.630.665.5000 Intl. Fax: 1.630.260.0842

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals