CHOWIS CDP-020-A Diagnosis System User Guide

June 5, 2024
CHOWIS

CHOWIS CDP 020 A Diagnosis System - LogoCHOWIS CDP 020 A Diagnosis System - Logo 2 Quick Start Guide
Model Name: CDP‐020‐A 

**Device Description and Specification

CHOWIS CDP 020 A Diagnosis
System**

Power Supply Input: 100‐240V, 50‐60Hz  Output: 12V,1‐2A
Magnification x20
Product size Handset: 15  6  7 (mm) Stand: 10.5  18.5  8 (mm)
Product weight Handset: about 150g Stand: 515g
Analysis result Index per measurement (0–99)
Measurement Moisture/Sebum, Pores, Spots, Impurities Wrinkles, Keratin

Turn On Device

  1. Plugin the USB cord to the dock to charge the handset.
    a. The Dp viso handset is on its docking.
    b. DC power socket located at the backside of docking
    c. The ba  very needs to be fully charged around
    4 hours and the device needs to be turned
     off.
    d. Single full charging enables the
    device to be used for around 2 hours
    e. Docking‐ handset holder charges the handset. CHOWIS CDP 020 A Diagnosis
System - Turn On Device

  2. Turn on the device by switching On/Off bu on.
    The measurement Indicator will have a blinking light. CHOWIS CDP 020 A
Diagnosis System - Turn On Device 2

Using App

Connecting Dermobella Skin App and Diagnosis

  1. Download and install “Dermobella Skin” on
    App Store for IOS or Google Play Store for Android. or scan QR codeCHOWIS
CDP 020 A Diagnosis System - QR Code 1http://l.ead.me/bb1W3R

  2. Input Optic Number on the app

  3. Connect with the device via Wi‐Fi with the default password: 1234567890

  4. Skin app: Total diagnosis and Quick diagnosis

Total Diagnosis shows a table of customers. Add, edit or delete customers, and also see or compare results.CHOWIS CDP 020 A Diagnosis System - Compare
Results Quick Diagnosis doesn’t need full customer information. Only needs: Gender > Age > Skin color group
Inside the Dermobella Skin App are 3 buttons on the upper right corner of the screen. 

  1. Wi‐Fi bu on for internet connection available.
  2. Settings b   on for setting  tions of the App
  3. Power bu on to shut down or restart the device.

How to Measure

Dermobella Skin Measurement

  1. Dermobella Skin has 3 programs to select from.
    a. Total Program covers all measurements: Moisture/Sebum,  Pore, Spots, Impuri es, Wrinkles, Keratin
    b. Personalized Program covers only customized and selected measurement the user wants to have.
    c. Moisture Program measures in‐depth analysis of the skin moisture

  2. How to measure moisture:
    a. Tap on the Tap screen
    b. Tap T‐Zone on the screen
    c. Put the Moisture sensor on the Forehead and press the Capture bu on the Handset
    d. Do the same for U‐zone.

  3. How to measure Sebum
    a. Dab Sebum T‐zone to forehead
    b. Dab Sebum U‐zone to lower cheek
    c. Tap on the screen
    d. Tap T‐zone and take an image on the sebum
    e. Tap U‐zone and take the image on the sebum

How to Measure Keratin
1. Peel off transparent film and press the tape on the skin for 6 seconds.
2. Capture an Image of keratin fi m as shown below

How to Measure

How to Capture Images

  1. Ensure that the camera fully and lightly touches the skin,  as shown below: CHOWIS CDP 020 A Diagnosis System - Touch the Screen
  2. Make sure when taking images, the camera is focused. As shown below:CHOWIS CDP 020 A Diagnosis System - Camera Focaced Sample shots:
Wrinkle Pore Impurities

CHOWIS CDP 020 A Diagnosis System - Simple Shots

How to Analyze

Results After Measurement

  1. Analyzing Diagnosis after all measurements
    a. Analyze one by one or Analyze all.

  2. Show all results
    a. Compare, Analyze or show a 3D view
    b. 3D view only applies to Pore and Wrinkle![CHOWIS CDP 020 A Diagnosis System

  • Show Results](https://manuals.plus/wp-content/uploads/2022/04/CHOWIS- CDP-020-A-Diagnosis-System-Show-Results-550x183.png)

    1. Full results
      a. Tap button to show results
      b. The “Results” button is on the upper right corner
      c. Full results will show graphs of all measurements

    2. The minimum distance that consumers use the product is 15 mm or more.
      (15 mm or more distance from the antenna).

‐ FCC §15.21 Information to the user.
The user’s manual or instruction manual for an intention l or unintentional l radiator shall cau on the user that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. In cases where the manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the information required by this section may be included in the manual in that alternate e form, provided the user can reasonably be expected to have the capability to access information in that form.
‐ FCC §15.105 Information to the user.
(b) For a Class B digital device or peripheral, the instruction furnished to the user shall include the following or similar statement, placed in a prominent location in the text of the manual:
Note:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular r installation If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,  the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
‐  FCC Notice :
1.1 Liability for illegal acts
Anyone who uses this product for illegal purposes shall be liable and he or she shall be held responsible for all and any consequences.
1.2 FCC licensing information
Federal Communication  Commission statement
NOTE: Change or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular r installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on,  the user is encouraged to try to correct the interference by one or more of the following measures.
‐ Reorient or relocate the receiving antenna.
‐ Increase the separation between the equipment and receiver.
‐ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
‐ Consult the dealer or an experienced radio, and TV technician for help.
‐ Only shielded interface cable should be used.
Finally, any changes or modification to the equipment by the user not expressly approved by the grantee or manufacturer could void the user’s authority to operate such equipment.
NOTE: Exposure to Radio Frequency Radiation Antenna shall be mounted in such a manner to minimize the potential for human contact during  normal operation
The antenna should not be contacted during operation to avoid the possibility of exceeding the FCC radio frequency exposure limit.
NOTE: This device complies with part 15 of the FCC Rules.
NOTE: Operation is subject to the following two conditions:
①  This device may not cause harmful interference, and
② This device must accept any interference received, including interference that may cause undesired operation
NOTE: This appliance and its antenna must not be co‐located or operated in conjunction with any other antenna or transmitter. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End-users must follow the specific operating in traction for satisfying RF exposure compliance.  This transmitter must not be co‐located or operating in conjunction with any other antenna or transmitter.  This transmitter is considered a mobile device and should not be used closer than 15 mm from a human body.

Scan to see Training Videos
Password: CHOWISDBSKIN2020 CHOWIS CDP 020 A Diagnosis System - QR Code
2https://l.ead.me/bbZDrOCHOWIS CDP 020 A Diagnosis
System - QR Code 3https://l.ead.me/bbZDlFCHOWIS CDP
020 A Diagnosis System - QR Code 4https://so.youku.com/search_video/q_chowis
Email: [email protected] 
Skype ID: Hello Chow is Skype

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CHOWIS User Manuals

Related Manuals