MyGenie X5 Cordless Vacuum Cleaner Instruction Manual
- June 5, 2024
- MyGenie
Table of Contents
MyGenie X5 Cordless Vacuum Cleaner
Warning
- Read this instruction booklet carefully.
- This appliance is for domestic use only. Use as described in this instruction booklet.
- Before using this appliance, check that the main power voltage corresponds to the voltage shown on the rating plate.
- Do not use the appliance to vacuum all the below things:
- water and other liquids hot ashes and other combustible things sharp matter wood pieces, gesso, cement, calcimine and other tiny granules
- Keep the vacuum cleaner away from stoves and heat-emitting appliance.
- Heat can deform and discolor the plastic parts of unit.
- Always remove the plug from the power socket when the appliance is not incharging.
- Never use spirits or other solvents to clean the appliance.
- Never leave the appliance unattended when it is switched on.
- Do not switch the appliance on if it appears to be faulty in any way.
- The battery must be removed from the appliance before its disposed.
- The battery is to be disposed of safely.
- The Appliance must be disconnected from the power when removing thebattery.
- Never use spirits or other solvents to clean the appliance.
- Do not put any object into openings. Do not use with any opening blocked;keep free of dust, lint, hair and anything that may reduce air flow.
- Keep hair, loose clothing, fingers, and all parts of body away from openingsand moving parts.
- Only the adapter provided by the manufacturer can be used.
- This appliance can be used by children aged from 8 years and above.
Description Of Parts
1.Cordless vacuum cleaner main unit | 2.Conductive aluminum tube |
---|---|
3.Electrical floor brush | 4.On/off button |
5. Bottom cover release button | 6.Removeable dust cup |
7. Battery Indicator light | 8. Conductive aluminum tube release button |
9.Floor brush release button | 10.Charge port |
11.Battery pack | 12. Dust cup release button |
13. Adapter | 14. 2 in 1 brush |
INSTRUCTION OF USE
Note:
Before using the Cordless Vacuum cleaner for the first time, clean it with a
soft, damp cloth and dry thoroughly. Do not immerse the Cordless Vacuum
cleaner in water or any other liquid.
Assembling the Cordless Vacuum cleaner
-
Assembling the aluminum tube
Fit the tube onto the main body’s air inlet until it clicks into position. If need to remove the tube, hold the main body, press the release knob and remove the tube
Assembling the electrical floor brush -
Fit the electrical floor brush onto the tube until it click into the position.
If need to remove the electrical floor brush, hold the aluminum tube, press the floor brush release knob and remove the brush from the tube.
-
Assembling the 2 in 1 brush
Fit the accessory on the main body’s air inlet and/or on the tube until it clicks into position.
The 2 in 1 brush is good for cleaning stairs, corners.
Operating the Cordless Vacuum cleaner
Before first time use, ensure the vacuum cleaner has been charged 4-4.5hours.
Turn on the Cordless vacuum cleaner by pressing the ON/OFF button.
Note: Battery indicator light represents battery capacity and will illuminate during use. The indicator light will turn off one by one as the battery runs out.
Warning: Do not use the Cordless Vacuum without the removable filter or dust bin in position.
Charging product
- Turn off the Cordless vacuum cleaner.
- Connect the adapter to the charge port on the main unit.
- Plug the adapter into the main power supply.
The battery indicator display light will flash in a ring. Once the battery is
fully charged, the battery indicator lights indicated by the battery are
always bright in a ring.
Warning: Do not use any main power adaptor other than that supplied, as using an alternative will increase the risk of injury and/or damage to main product.
CARE AND MAINTENANCE
Filter replacement and cleaning
-
Turn off the Cordless vacuum cleaner
-
Press and hold the dust cup release button and rotate the dust cup at a clockwise angle of 30 °, then remove the whole dust cup.
-
How to clean the dust cup Without removing the dust cupPress the dust cup release button directly, Then drop the dust into waste container.(fig. A)
Or you can remove the dust cup and Press the dust cup release button directly, Then drop the dust into waste container.(fig. B) -
Remove filter assembly: Filter, Hepa , Dust cup
-
Cleaning the filter/hepa in water, wait for it to dry completely.
-
Put the filter/hepa back into the dust cup carefully.
-
Put the dust cup back into the main body: Dust cup counterclockwise rotation into the slot, hear the sound of “ka”, that means the dust cup installed in place.
Rotating brush cleaning
- Turn the brush bottom screw to unlock position (picture)
- Open the brush bottom fixed device.
- Show brush, clean the rotating brush on the twisting thing.
- Put the rotating brush back.
- Turn the brush bottom screw to lock position
BATTERY REMOVAL AND DISPOSAL
Discarded batteries are nonenvironmentally friendly and disposed of it in accordance with applicable regulations.
- Discharge the battery by running the appliance to stop the engine at idle.
- Remove the battery from the appliance.
Attention:
The battery pack of this model vacuum cleaner is Non-removable. If you need to replace battery pack ,Please send it to a professional maintenance station.
PRODUCT TECHNICAL PARAMETERS
Model number | Mygenie X5 |
---|---|
Rated power | 120W |
Model output | 22.2V |
Input | 100-240V/ 50-60Hz |
Output | 26V 450mA |
Mode: -High -Low | 10Kpa/ 15-22mins 7Kpa/ 27-35mins |
Charging time | 4H |
TROUBLE SHOOTING GUIDE
PROBLEM| POSSIBLE REASON| POSSIBLE SOLUTION
HAND VACUUM WILL NOT OPERATE|
- no power in electrical outlet supplying transformer
- unit needs servicing
|
- check fuse or breaker .replacefuse/reset breaker.
HAND VACUUM WILL NOT PICK-UP OR SUCTION POWER IS WEAK|
- Dust cup is full.
- Dust cup filter needs cleaning.
|
- Empty dust cup. Remove dust cup filter and checkfor object(s) in air duct andremove.
DUST ESCAPING FROM HAND VACUUM|
- Dust cup is full.
- Dust cup filter is not installed correctly.
- Puncture/hole in dust cup filter.
|
- Empty dust cup .
- Review dust cup filterinstruction.
- Replace dust cup filter.
HAND VACUUM BRUSHES WILL NOT PICK-UP|
- Dust cup is full.
|
- Empty and clean dust cupcontainer.
Warranty Information
The manufacturer provides warranty in accordance with the legislation of the customer’s own country of residence, with a minimum of 1 year, starting from the date on which the appliance is sold to the end user. The warranty only covers defects in material or workmanship. The repairs under warranty may only be carried out by an authorized service centre. When making a claim under the warranty, the original bill of purchase (with purchase date) must be submitted. The warranty will not apply in cases of:
- Normal wear and tear
- Incorrect use, e.g. overloading of the appliance, use of non-approved accessories
- Use of force, damage caused by external influences
- Damage caused by non-observance of the user manual, e.g. connection to an unsuitable mains supply or non-compliance with the installation instructions
- Partially or completely dismantled appliances
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>