testoon FPC1000 R and S FPC Spectrum Analyzer User Guide
- June 5, 2024
- testoon
Table of Contents
testoon FPC1000 R and S FPC Spectrum Analyzer
This document describes the following products:
- R&S®FPC1000 (1328.6660K02)
- R&S®FPC1500 (1328.6660K03)
Safety and regulatory information
The product documentation helps you use the product safely and efficiently.
Follow the instructions provided here and in the following chapters.
Intended use
The product is intended for the development, production and verification of
electronic components and devices in industrial, administrative, and
laboratory environments. Use the product only for its designated purpose.
Observe the operating conditions and performance limits stated in the data
sheet.
Where do I find safety information?
Safety information is part of the product documentation. It warns you of
potential dangers and gives instructions on how to prevent personal injury or
damage caused by dangerous situations. Safety information is provided as
follows:
- In Chapter 1.1, “Safety Instructions”, on page 3. The same information is provided in many languages as printed “Safety Instructions”. The printed “Safety Instructions” are delivered with the product.
- Throughout the documentation, safety instructions are provided when you need to take care during setup or operation.
Safety Instructions
Products from the Rohde & Schwarz group of companies are manufactured
according to the highest technical standards. To use the products safely,
follow the instructions provided here and in the product documentation. Keep
the product documentation nearby and offer it to other users.
Use the product only for its intended use and within its performance limits.
Intended use and limits are described in the product documentation such as the
data sheet, manuals and the printed “Safety Instructions”. If you are unsure
about the appropriate use, contact Rohde & Schwarz customer service.
Using the product requires specialists or specially trained personnel. These
users also need sound knowledge of at least one of the languages in which the
user interfaces and the product documentation are available.
Safety Instructions
Never open the casing of the product. Only service personnel authorized by
Rohde & Schwarz are allowed to repair the product. If any part of the product
is damaged or broken, stop using the product. Contact Rohde & Schwarz customer
service at http://www.customersupport.rohde-schwarz.com.
Lifting and carrying the product
The maximum weight of the product is provided in the data sheet. To move the
product safely, you can use lifting or transporting equipment such as lift
trucks and forklifts. Follow the instructions provided by the equipment
manufacturer.
Choosing the operating site
Only use the product indoors. The product casing is not waterproof. Water that
enters can electrically connect the casing with live parts, which can lead to
electric shock, serious personal injury or death if you touch the casing. If
Rohde & Schwarz provides accessories designed for your product, e.g. a
carrying bag, you can use the product outdoors.
Unless otherwise specified, you can operate the product up to an altitude of
2000 m above sea level. The product is suitable for pollution degree 2
environments where nonconductive contamination can occur. For more information
on environmental conditions such as ambient temperature and humidity, see the
data sheet.
Setting up the product
Always place the product on a stable, flat and level surface with the bottom
of the product facing down. If the product is designed for different
positions, secure the product so that it cannot fall over.
If the product has foldable feet, always fold the feet completely in or out to
ensure stability. The feet can collapse if they are not folded out completely
or if the product is moved without lifting it. The foldable feet are designed
to carry the weight of the product, but not an extra load.
If stacking is possible, keep in mind that a stack of products can fall over
and cause injury.
If you mount products in a rack, ensure that the rack has sufficient load
capacity and stability. Observe the specifications of the rack manufacturer.
Always install the products from the bottom shelf to the top shelf so that the
rack stands securely. Secure the product so that it cannot fall off the rack.
Connecting to power
The product is an overvoltage category II product. Connect the product to a
fixed installation used to supply energy-consuming equipment such as household
appliances and similar loads. Keep in mind that electrically powered products
have risks, such as electric shock, fire, personal injury or even death.
Take the following measures for your safety:
- Before switching on the product, ensure that the voltage and frequency indica-ted on the product match the available power source. If the power adapter does not adjust automatically, set the correct value and check the rating of the fuse.
- Only use the power cable delivered with the product. It complies with country-specific safety requirements. Only insert the plug into an outlet with protective conductor terminal.
- Only use intact cables and route them carefully so that they cannot be dam-aged. Check the power cables regularly to ensure that they are undamaged. Also ensure that nobody can trip over loose cables.
- If the product needs an external power supply, use the power supply that is delivered with the product or that is recommended in the product documentation or a power supply that conforms to the country-specific regulations.
- Only connect the product to a power source with a fuse protection of maxi-mum 20 A.
- Ensure that you can disconnect the product from the power source at any time. Pull the power plug to disconnect the product. The power plug must be easily accessible. If the product is integrated into a system that does not meet these requirements, provide an easily accessible circuit breaker at the system level.
Connecting headphones
Take the following measures to prevent hearing damage. Before using head-
phones, check the volume and reduce it if necessary. If you monitor varying
signal levels, take off the headphones and wait until the signal has settled.
Then adjust the volume.
Cleaning the product
Use a dry, lint-free cloth to clean the product. When cleaning, keep in mind
that the casing is not waterproof. Do not use liquid cleaning agents.
Meaning of safety labels
Safety labels on the product warn against potential hazards.
Labels on R &S FPC
Labels on the casing inform about:
- Personal safety, see “Meaning of safety labels” on page 6
- Product and environment safety, see Table 1-1
- Identification of the product, see “Device ID” on page 19
Table 1-1: Labels regarding R&S FPC and environment safety
Labeling in line with EN 50419 for disposal of electrical and electronic equipment after the product has come to the end of its service life. For more information, see the prod-uct user manual, chapter “Disposal”.
Warning messages in the documentation
A warning message points out a risk or danger that you need to be aware of.
The signal word indicates the severity of the safety hazard and how likely it
will occur if you do not follow the safety precautions.
CAUTION
Potentially hazardous situation. Could result in minor or moderate injury if
not avoided.
NOTICE
Potential risks of damage. Could result in damage to the supported product or
to other property.
Regulatory information
Instruments with a serial number < 200000 have an internal Wi-Fi module. You
can access the regulatory information for this module in the firmware of the
R&S FPC.
-
Press the “Setup” key.
The R&S FPC opens the “Instrument Setup” menu. -
Select the “Regulatory Information” menu item in the “WiFi” category with the “Enter” key.
The R&S FPC shows the regulations it complies with.
Korea certification class A
Documentation overview
This section provides an overview of the R&S FPC user documentation. You can
find it on the product page at:
www.rohde-schwarz.com/manual/fpc
Getting started manual
Introduces the R&S FPC and describes how to set up and start working with the
product. A printed version is included in the delivery.
User manual
The user manual contains the description of all instrument modes and
functions. It also provides an introduction to remote control, a complete
description of the remote control commands with programming examples, and
information on main-tenance, instrument interfaces and error messages.
In addition to the R&S FPC user manual, there is a separate user manual for
the R&S InstrumentView software package. This manual contains a description of
all features of the R&S InstrumentView software package.
The online version (html format) of the user manual provides the complete con-
tents for immediate display on the internet.
The user manual is also integrated into the firmware (.chm format). You can
export the file to a memory stick (“Setup” > “User Preferences” > “Export
Documentation”. After the export, you can connect the memory stick to a PC and
read the .chm file.
Service manual
Describes the performance test for checking the rated specifications, module
replacement and repair, firmware update, troubleshooting and fault
elimination, and contains mechanical drawings and spare part lists.
The service manual is available for registered users on the global
Rohde & Schwarz information system (GLORIS, https://gloris.rohde-
schwarz.com).
Basic safety instructions
Contains safety instructions, operating conditions and further important
informa-tion. The printed document is included in the delivery.
Data sheet and brochure
The data sheet contains the technical specifications of the R&S FPC. It also
lists the options and their order numbers as well as optional accessories.
The brochure provides an overview of the R&S FPC and shows its specific char-
acteristics.
Release notes and open source acknowledgment
The release notes list new features, improvements and known issues of the cur-
rent firmware version, and describe the firmware installation.
The open source acknowledgment document provides verbatim license texts of the
used open source software.
www.rohde-schwarz.com/manual/fpc
The open source acknowledgement is also integrated into the firmware (.chm
for-mat). You can export the file to a memory stick (“Setup” > “User
Preferences” > “Export Documentation”. After the export, you can connect the
memory stick to a PC and read the .chm file.
Application notes, application cards, white papers, etc.
These documents contain information about possible applications and back-
ground information on various topics, see
www.rohdeschwarz.com/appnotes
Calibration certificates
The calibration certificates of your device are available online. Visit the
R&S FPC product page and select the item to download the calibration
certificate. You will be forwarded to a Gloris page.
https://gloris.rohde-schwarz.com/calcert
Enter the device ID of your R&S FPC and download the certificate. You can find
the device ID either in the “Setup” menu or on the label on the rear panel.
Preparing for use
Here, you can find basic information about setting up the product for the first time.
Lifting and carrying
See “Lifting and carrying the product” on page 4.
Unpacking and checking the instrument
- Unpack the R&S FPC carefully.
- Retain the original packing materials. Use it when transporting or shipping the R&S FPC later.
- Using the delivery notes, check the equipment for completeness.
- Check the R&S FPC for any damage.
If the delivery is incomplete or the equipment is damaged, contact Rohde & Schwarz.
Choosing the operating site
Specific operating conditions ensure proper operation and avoid damage to the
product and connected devices. For information on environmental conditions
such as ambient temperature and humidity, see the data sheet.
See also “Choosing the operating site” on page 4.
Electromagnetic compatibility classes
The electromagnetic compatibility (EMC) class indicates where you can operate
the product. The EMC class of the product is given in the data sheet under
“General data”.
-
Class B equipment is suitable for use in:
Residential environments
Environments that are directly connected to a low-voltage supply network that supplies residential buildings -
Class A equipment is intended for use in industrial environments. It can cause radio disturbances in residential environments due to possible conducted and radiated disturbances. It is therefore not suitable for class B environments. If class A equipment causes radio disturbances, take appropriate measures to eliminate them.
Setting up the R &S FPC
The R&S FPC is designed for use on a bench top or in a rack. See also:
- “Setting up the product” on page 4
- “Intended use” on page 3
Placing the R &S FPC on a bench top
To place the product on a bench top
-
Place the product on a stable, flat and level surface. Ensure that the surface can support the weight of the product. For information on the weight, see the data sheet.
-
CAUTION! Foldable feet can collapse. See “Setting up the product” on page 4.
Always fold the feet completely in or out. With folded-out feet, do not place anything on top or underneath. -
Alternatively, you can mount several products in a rack.
Mounting the R &S FPC in a rack
To prepare the rack
- Observe the requirements and instructions in “Setting up the product” on page 4.
- NOTICE! Insufficient airflow can cause overheating and damage the product. Design and implement an efficient ventilation concept for the rack.
To mount the R &S FPC in a rack
-
Use an adapter kit to prepare the R&S FPC for mounting.
a) Order the rack adapter kit designed for the R&S FPC (19″ rack mount kit R&S ZZA-FPC1 order no. 1328.7080.02).
b) Mount the adapter kit. Follow the installation instructions provided with the adapter kit. -
Lift the R&S FPC to shelf height.
-
Push the R&S FPC onto the shelf until the rack brackets fit closely to the rack.
-
Tighten all screws in the rack brackets with a tightening torque of 1.2Nm to secure the R&S FPC in the rack.
To unmount the R &S FPC from a rack
- Loosen the screws at the rack brackets.
- Remove the R&S FPC from the rack.
- If placing the R&S FPC on a bench top again, unmount the adapter kit from the R&S FPC. Follow the instructions provided with the adapter kit.
Considerations for test setup
Signal input and output
An unsuitable test setup can damage the instrument and connected devices.
Before you switch on the instrument, check that all inputs and outputs are
correctly connected and that the signal levels are within the specified ranges
defined in the data sheet.
In particular, pay attention to the following limits to avoid damage to the
R&S FPC:
- Do not overload the RF input and keep within the maximum allowed signal level defined in the data sheet.
- Never exceed a DC input voltage of 50 V at the RF input.
- Never exceed a reverse power of 23 dBm at the signal source output.
Cable selection and electromagnetic interference (EMI)
Electromagnetic interference (EMI) can affect the measurement results. To suppress electromagnetic radiation during operation:
- Use high-quality shielded cables, for example, double-shielded RF and LAN cables.
- Always terminate open cable ends.
- Ensure that connected external devices comply with EMC regulations.
Connecting AC power
The AC power connector on the rear panel of the R&S FPC allows you to connect
it to the primary power supply.
Included in the delivery of the R&S FPC are several common power plug types.
- Select the cable with the plug type you need and firmly connect it to the R&S FPC.
- Connect the AC plug to the power outlet to supply the R&S FPC with power. The R&S FPC is assembled in line with the specifications for safety class EN61010. Therefore, it may only be connected to an outlet that has a ground contact.
The AC power supply has the following characteristics.
● Line voltage: 100 V AC to 240 V AC
● Line frequency: 50 Hz to 60 Hz; 400 Hz
● Current: 0.6 A to 0.4 A
See also “Connecting to power” on page 5.
Turning the R &S FPC on and off
After you have established a connection to the power supply, you can turn on
the R&S FPC.
Table 3-1: Overview of power states
Turning on the R &S FPC
Turn on the main AC power switch on the rear panel of the R&S FPC (position
“I”).
The instrument is now supplied with AC power.
- “Power” key is highlighted orange: R&S FPC is in standby mode (main AC power switch is in position “I”).
- “Power” key is highlighted green: R&S FPC is running and ready for operation.
Turning off the R &S FPC
- Turn off the main AC power switch on the rear panel of the R&S FPC (position “O”).
The instrument is no longer supplied with AC power.
To disconnect from power
The product is in the standby state.
-
NOTICE! Risk of data loss. If you disconnect the product from power when it is in the ready state, you can lose settings and data. Shut it down first.
Set the switch on the power supply to position [0].
The LED of the Power key is switched off. -
Disconnect the product from the power source.
Instrument tour
The R&S FPC has various connectors on the front and rear panel.
Front panel
Figure 4-1: Front panel of the R&S FPC
- = USB ports (type A)
- = Headphone jack
- = Softkeys
- = Signal source output
- = Function keys and alphanumeric keypad
- = RF Input
- = Power switch
Power switch
The power switch turns the R&S FPC on and off when it is supplied with power.
For more information, see Chapter 3.7, “Turning the R&S FPC on and off”, on
page 14.
Signal source output
Available on the R&S FPC1500.
Front panel The “Signal Source” output allows you to generate a signal that can be fed into the DUT or other external accessories like frequency dividers or amplifiers. You can connect the DUT or accessories with a cable that has a male N connector.
Headphone jack
The female headphone jack allows you to connect headphones (or external
speakers) with a miniature jack plug.
You can control the output voltage with the volume control integrated into the
firm-ware. Refer to the user manual for details.
If you connect headphones or external speakers, the R&S FPC automatically
turns off the internal speaker.
Note the safety information provided in “Connecting headphones” on page 5.
USB ports (type A)
The two USB 2.0 ports on the front panel (type A) allow you to connect devices
like memory sticks.
Function keys and alphanumeric keypad
The function keys provide access to the measurement settings and functions.
The alphanumeric keypad allows you to enter alphanumeric data if necessary.
Refer to the user manual for a comprehensive description of the function keys.
Softkeys
The softkeys allow you to access measurement settings and functions.
Softkeys are dynamic. A different list of softkeys is displayed depending on
the selected function key. A list of softkeys for a certain function key is
also called a menu.
Softkeys can either perform a specific function or open a dialog box.
Refer to the user manual for a comprehensive description of the function keys.
RF Input
The RF input with an impedance of 50 Ω allows you to connect a DUT to the R&S
FPC. Typically, you connect the DUT with a cable and an appropriate connector
(for example a male N connector).
The frequency range of the RF input is specified in the datasheet. The attenuation range is between 0 dB and 40 dB.
Rear panel Figure 4-2: Rear panel of the R&S FPC
- = Trigger input / external reference
- = LAN
- = USB port (type B)
- = Power supply
Power supply
The AC power supply and main power switch are located in a unit on the rear
panel of the instrument.
The main power switch has the following states.
- Position “1”: The instrument is supplied with power.
- Position “0”: The instrument is disconnected from the power supply.
Trigger input / external reference
This female BNC connector allows you to connect an external trigger signal or
an external reference signal.
When you are using the connector as a trigger input, you can trigger measure-
ments with an external trigger. For more information about triggered
measurements, refer to the user manual.
Alternatively, you can use the connector to connect a 10 MHz reference signal
to synchronize the frequency with the external reference. Note that the
reference signal must be stronger than 0 dBm.
LAN
The LAN interface allows you to connect the R&S FPC to a local network for
remote control, printouts or data transfer. The assignment of the RJ-45
connector supports twisted-pair category 5 UTP/STP cables in a star
configuration (UTP stands for unshielded twisted pair, and STP for shielded
twisted pair).
USB port (type B)
The USB port (type B) allows you to connect the R&S FPC to a computer and
establish a remote control connection.
Device ID
The unique device identifier is provided as a barcode sticker on the rear
panel of the R&S FPC.
It consists of the serial number and a 2-character checksum.
The device ID is defined as the following example:
1310.3004.02-123456-ab
1310.3004.02 = Order number
123456 = Serial number
ab = Checksum
The instrument name is required to establish a connection to the instrument in
a LAN.
© 2021 Rohde & Schwarz GmbH & Co. KG
Mühldorfstr. 15, 81671 München, Germany
Phone: +49 89 41 29 – 0
Email: info@rohde-schwarz.com
Internet: www.rohde-schwarz.com
Subject to change – data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
Trade names are trademarks of the owners.
1328.7409.02 | Version 05 | R&S®FPC
Throughout this manual, products from Rohde & Schwarz are indicated without
the ® symbol and without the model designation, e.g. R&S®FPC1000 is indicated
as R&S FPC.
References
- 📧info@rohde-schwarz.com
- Customer support | 24/7 | Rohde & Schwarz
- Home - GLORIS Rohde & Schwarz
- Calibration Certificates - GLORIS Rohde & Schwarz
Read User Manual Online (PDF format)