SCT RC7-PD2 Camera Extension Kit for Poly Director II User Guide

June 5, 2024
SCT

SCT RC7-PD2 Camera Extension Kit for Poly Director II

RC7-PD2™ Application

RC7-PD2™ Installation

Supporting the Poly EagleEye Director II and Group Series 300, 500, 700 & 7500 Codecs

TEST YOUR SCTLink™ CABLE

We highly recommend using an Ethernet Network Tester/Analyzer alongside our provided PowerSniffer to confirm your SCTLink™ wiring. Our PowerSniffer only tests conductor continuity and will not identify data integrity or capacity issues.

  1. Test and verify your CAT6 STP or UTP SCTLink™ cable for EIA568A or EIA568B.
    The SCTLink™ cable must be between 10m (minimum) and 100m (maximum) length.

  2. Connect one end of the SCTLink™ cable to the “SCTLink™” connection on the Head End module.

  3. Connect the other end of your SCTLink™ cable to the provided PowerSniffer.

  4. Connect the WPS-48 power supply to the Head End module.

  5. Connect the WPS-48 power supply to AC mains.

  6. If the SCTLink™ cable is properly terminated, it will display eight GREEN LEDs.
    If you get any other result, stop and re-terminate cable.

  7. Once your SCTLink™ cable has been tested, please disconnect the WPS-48 power supply from the RC7-HE module, and the PowerSniffer from the SCTLink™ cable, before proceeding to install.

INSTALL THE EXTENSION KIT

Before integrating your RC7-PD2™ extension kit, please ensure your Poly EagleEye Director II base is connected to your two EagleEyeIV cameras (Power and Ethernet connections) via Poly’s instructions.

Connect the camera-end cables:

  1. Connect the RCC-C030 mini-HDCI end to the mini-HDCI input on the EagleEye Director II base.
    • Connect the RCC-C030 HDMI leg cable to the RC7-CE’s HDMI “HDMI In” port.
    • Connect the RJ45 leg cable to the RC7-CE’s “Power Serial/IR” port.

  2. Connect the RCC-C016 1’ Audio Cable between the RC7- CE “Line Out” port and the EagleEye Director II’s audio TRS input.

  3. Connect the PPC-015 Power Cable between the EagleEye Director II’s power input and the RC7-CE’s power input, labeled “+12VDC Output”.

  4. Connect the RCC-H030’s HDCI end to the primary HDCI input on the Group Series codec.
    • Connect the HDMI leg cable to the RC7-HE’s HDMI “Output 1” port.
    • Connect the 9Pin leg cable to the RC7-HE’s port labeled ‘Serial/IR’.

  5. Connect the Polycom supplied audio cable between the RC7-HE’s “Line In” port and the Group Series Codec’s audio inputs.
    • Connect and Initiate the Extended System:

  6. Connect one end of your CAT6 SCTLink™ cable to the RC7-HE module’s “SCTLink™” port. Connect the other end to the RC7-CE module’s “SCTLink™” port.

  7. Connect the WPS-48 Power Supply to the RC7-HE.

• ALLOW UP TO TWO MINUTES FOR THE EAGLEEYE DIRECTOR II SYSTEM TO INITIALIZE •

Installation Status – Refer to our modules’ LEDs for installation status.
For assistance troubleshooting INACTIVE LED statuses, please contact Tech Support at 203-854-5701.

MODULE LED LABEL ACTIVE STATUS INACTIVE STATUS
RC7-CE OK LED Blinking Green (~1 second interval) Blinking or Solid Red
RC7-HE OK LED Blinking Green (~1 second interval) Blinking or Solid Red
RC7-HE LINK LED Solid Green Solid Red or Dormant

Cable Table – Part numbers, descriptions and functions of all provided SCT cables.
This kit includes [1] RC-RKM™ Rack Shelf.

CABLE DESCRIPTION FUNCTION
RCC-C030-0.4M HDMI/RJ45 to Mini-HDCI Cable Video/control connection between

Director II base and RC7-CE Module.
RCC-C016-0.3M| Audio Cable| Audio connection between Director II base and RC7-CE module.
PPC-015-0.4M| Power Cable| Supplies power from RC7-CE module to the Director II base.
RCC-H030-1.0M| HDMI/ DB9 to HDCI| Video/control connection between RPG Series Codec and RC7-HE module.

Power Supply Specifications (AC-Mains Side): Input Voltage: 100VAC to 240VAC 47Hz to 63Hz. Efficiency: 85% minimum.
Turn-on Surge: Less than 60 amperes for a duration less than 1mS. Power Factor: 0.9 minimum (where applicable). 48VDC power supply uses 2.80 amperes AC maximum. All specifications subject to change without notice.

TECH SUPPORT:203-854-5701WWW.SOUNDCONTROL.NET • ©SOUND CONTROL TECHNOLOGIES, INC