DO NOT RETURN THIS PRODUCT TO THE STORE
If you have any problems or questions, contact our U.S.-based Consumer Care at 1-800-654-8483, option 1, Monday–Friday, 7:00AM–8:00PM CST. For the most up-to-date product support, accessories, electronic (PDF) format manuals and more, visit www.byjasco.com/support.
No user-serviceable parts in this unit.
WARNING
RISK OF FIRE
RISK OF ELECTRICAL SHOCK RISK OF BURNS
CONTROLLING APPLIANCES CAUTION:
- DO NOT EXCEED RATINGS
- DO NOT USE TO CONTROL ANY DEVICE WHERE UNINTENDED OPERATION COULD CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)
- DO NOT USE TO CONTROL RECEPTACLE
- FOR INDOOR USE ONLY
NOT FOR USE WITH MEDICAL OR LIFE-SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES SHOULD NEVER BE USED TO SUPPLY POWER TO OR CONTROL THE
ON/OFF STATUS OF MEDICAL OR LIFE-SUPPORT EQUIPMENT.
SPECIFICATIONS
- Power: 120/277VAC, 60Hz
- Operating temperature range: 32-104° F (0-40° C)
- Type 1 action
- For indoor use only
- Specifications are subject to change without notice due to continuing product improvement
IMPORTANT!
The add-on switch is not wireless-enabled and must be used exclusively with
one of the Jasco wireless devices. It is not designed for stand-alone use to
control an electrical load. It does not have wireless functionality and does
not act as a repeater in your wireless control network
WARRANTY
Jasco Products Company warrants this product to be free from manufacturing
defects two years from the original date of consumer purchase. This warranty
is limited to the repair or replacement of this product only and does not
extend to consequential or incidental damage to other products that may be
used with this product. This warranty is in lieu of all other warranties,
expressed or implied. Some states do not allow limitations on how long an
implied warranty lasts or permit the exclusion or limitation of incidental or
consequential damage, so the above limitations may not apply to you. This
warranty gives you specific rights, and you may also have other rights which
vary from state to state. Please contact our U.S.-based Consumer Care at
1-800-654-8483 (option 1) between 7 AM
– 8 PM CST or www.byjasco.com if the unit should
prove defective within the warranty period.
Tools You Will Need
Changing paddle color
This step is optional. Before installation, you may want to change the color
of the paddle to match your wallplate or décor.
- Push side tabs in on one side and then the other to release paddle. Lift the cover up and off
- Simply put the new paddle onto the switch by aligning side tabs and snapping securely into place.
- Once this step has been completed, proceed to section 3.
Jasco switch
Standard 3-way switch
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture
at the service panel. All wiring connections must be made with the POWER OFF
to avoid personal injury and/or damage to the switch. This device is intended
for installation in accordance with the National Electric Code and local
regulations in the United States or the Canadian Electrical Code and local
regulations in Canada. If you are unsure or uncomfortable about performing
this installation, consult a qualified electrician.
IMPORTANT!
3-way switches can be wired in different ways. These instructions explain the
most common method. If you have difficulty with the instructions or your home
wiring, contact a licensed electrician for assistance.
- Shut off power to the circuit at circuit breaker or fuse box. IMPORTANT! Verify power is OFF to switch box before continuing.
- Remove both wallplates.
- Remove the switch mounting screws.
- Carefully remove the switch from each switch box location. DO NOT disconnect the wires yet.
- Identify switch connected to fuse box. This is the line switch. Label wire connected to common terminal “LINE.
- Identify switch connected to lighting/fixture. This is the load switch. Label wire connected to common terminal “LOAD.”
Observe important wiring information
IMPORTANT! This add-on switch is rated for and intended to only be used
with copper wire.
Wire gauge requirements
Use 14AWG or larger wires suitable for at least 80° C for supplying line,
load, neutral, ground and traveler connections.
Wire strip length
- For attachment to screw terminals, strip insulation 1in. (25mm).
- For attachment using the enclosure’s holes, strip insulation 5/8in. (16mm).
- UL specifies tightening torque for the screws is 14Kgf-cm (12lbf-in).
Switch connected to fuse box line switch (Replacing standard switch with Jasco primary switch)
- Disconnect all wires on existing switch.
- Locate neutral wires found inside switch box. These are typically a bundle of white wires in the back of the box. Remove wire nut securing them (A).
- Locate jumper wire. Connect with neutral wires and secure with wire nut (A).
- Connect opposite end of jumper wire to the NEUTRAL terminal on primary switch (B).
- Connect wire labeled “LINE” to LINE terminal on primary switch (C).
- Connect ground wire (bare/copper/green) to GROUND terminal on primary switch (D).
- Connect one of the two remaining wires (T1) to the LOAD terminal on primary switch (E). Write down the color of the wire. You will need this when installing the add-on switch.
- Connect the remaining wire (T2) to the TRAVELER terminal on the primary switch (F). Switch connected to lighting “load switch”
(replacing standard switch with Jasco Add-on Switch)
- Disconnect all wires on existing switch.
- Locate neutral wires found inside switch box. These are typically a bundle of white wires in the back of the box. Remove wire nut securing them (AA).
- Locate jumper wire included in packaging of primary switch. Connect with neutral wires and secure with wire nut (AA).
- Connect opposite end of jumper wire to NEUTRAL terminal on add-on switch (BB).
- Connect ground wire (bare/copper/green) to GROUND terminal on add-on switch (CC).
- Locate the same colored wire wrote down in the switch box (T1). Using a wire nut, secure it only to the wire you labeled “LOAD.”
- Connect the remaining wire to TRAVELER terminal on the add-on switch (DD). This will be the same color as the wire connected to TRAVELER terminal on the primary switch.
Attach switch to box
- Place both switches into their respective switch boxes being careful not to pinch or crush wires.
- Secure each switch to the box using the supplied screws.
- Mount each switch wallplate.
- Reapply power to the circuit at fuse box or circuit breaker and test the system.