SAUBER VCE-125693.1 Cyclone Vacuum Cleaner Instruction Manual

June 5, 2024
Sauber

SAUBER VCE-125693.1 Cyclone Vacuum Cleaner

SAUBER VCE-125693.1 Cyclone Vacuum Cleaner

SAFETY INSTRUCTIONS

Before use make sure to read all of the below instructions in order to avoid injury or damage, and to get the best results from the appliance. Make sure to keep this manual in a safe place. If you give or transfer this appliance to someone else make sure to also include this manual.
In case of damage caused by user failing to follow the instructions in this manual the warranty will be void. The manufacturer/importer accepts no liability for damages caused by failure to follow the manual, a negligent use or use not in accordance with the requirements of this manual.

  1. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  2. Children shall not play with the appliance.
  3. Cleaning and user maintenance shall not be made by children without supervision.
  4. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  5. Before inserting the plug into the mains socket, please check that the voltage and frequency comply with the specifications on the rating label.
  6. Disconnect the mains plug from the socket when the appliance is not in use and before cleaning.
  7. Ensure that the mains cable is not hung over sharp edges and keep it away from hot objects and open flames.
  8. Do not immerse the appliance or the mains plug in water or other liquids. There is danger to life due to electric shock!
  9. To remove the plug from the plug socket, pull the plug. Do not pull the power cord.
  10. Do not touch the appliance if it falls into water. Remove the plug from its socket, turn off the appliance and send it to an authorized service center for repair.
  11. Do not plug or unplug the appliance from the electrical outlet with a wet hand.
  12. Never attempt to open the housing of the appliance, or to repair the appliance yourself. This could cause electric shock.
  13. Never leave the appliance unattended during use.
  14. This appliance is not designed for commercial use.
  15. Do not use the appliance for other than intended use.
  16. Do not wind the cord around the appliance and do not bend it.
  17. The use of accessory attachment not recommended by the appliance manufacturer may cause injuries.
  18. Do not put any object into openings. Do not use with any opening blocked. Keep free of dust, lint, hair and anything that may reduce airflow.
  19. Do not pick up hard or sharp objects such as glass, nails, screws, coins, etc.
  20. Do not pick up hot coals, cigarette, matches or any hot, smoking, or burning objects.
  21. Do not use this appliance without filters in place.
  22. Use extra care when vacuuming on stairs.
  23. Do not pick up flammable or combustible materials (lighter fluid, gasoline, etc.) or use in the presence of explosive liquids or vapor.
  24. Do not pick up toxic material (chlorine bleach, ammonia, drain cleaner, etc.).
  25. Do not operate the appliance in an enclosed space filled with vapors given off by oil based paints, paint thinner, moth proofing, flammable dust, or other explosive or toxic vapors.
  26. Keep your work area well dry.
  27. Do not use the cleaner to clean your pets or any animal.
  28. When using and you hear a squeaking sound from the vacuum cleaner, or suction power appears to be reduced, stop the machine immediately and clean all filters.
  29. WARNING: Hold the plug when rewinding the cord. Do not allow the cord to whip when rewinding.
  30. Tip: By reducing the suction power you can move the floor brush easier on the floor. Set the suction power to minimal for furniture, to medium for carpet and hard floors. Only use the maximum setting on hard floors in combination with a brush for hard floors.

The general purpose vacuum cleaner (model VCE-125693.1), has been tested according to EN 60312-1 and complies with the essential requirements of regulation (EU) 666/2013 for vacuum cleaners.

USE AND FUNCTION

Assembling vacuum cleaner
Note:
Always remove the power plug from the wall outlet before assembling or removing accessories.

  1. Attaching the flexible hose into the vacuum cleaner. Align the rim and insert the flexible hose into the air inlet socket.
    SAUBER VCE-125693.1 Cyclone Vacuum Cleaner-1

  2. Fitting the tube to the curved wand/hose extension.

  3. Fitting the floor brush to the tube. Push the tube into the floor brush. Adjust the tube to the desired length. Tip: By reducing the suction power you can move the floor brush easier on the floor. Set the suction power to minimal for furniture, to medium for carpet and hard floors. Only use the maximum setting on hard floors in combination with a brush for hard floors.

BUTTON FUNCTION INTRODUCTION
Note:
Once all attachments are in place, unwind a sufficient length of cable and insert the plug into the wall outlet. A yellow mark on the power cord shows the ideal cable length. Do not pull the power cord beyond the red mark.

  1. Insert the power plug into the wall outlet.
  2. Press the on/off button located on the unit to turn the vacuum cleaner “on”. To adjust the suction, rotate the speed control button to control the suction power of the vacuum cleaner.
  3. To rewind the power cord, press the cord rewind button with one hand and guide the power cord with the other hand to ensure that it does not whip causing damage or injury.

SAUBER VCE-125693.1 Cyclone Vacuum Cleaner-2

CLEAN THE DUST CUP

Note the MAX level on the dust cup in case it becomes too full. To clean the dust cup, follow the steps below. Warning: Always unplug the unit from electrical outlet before getting out the dust cup.

  1. Press the dust cup release button and hold the dust cup out.
  2. Pull out the clip of the dust cup to open the dust cup cover.

SAUBER VCE-125693.1 Cyclone Vacuum Cleaner-3

CLEAN THE MOTOR PROTECTION FILTER

  1. First, take out the dust cup.

  2. You will find the motor protection filter (A) on the machine. Take the filter out for cleaning. Dry it thoroughly before placing it back.

  3. The motor protection filter should be removed and rinsed twice a year or whenever it is visibly clogged.

  4. If the filter is damaged, a new filter should be replaced.

SAUBER VCE-125693.1 Cyclone Vacuum Cleaner-4

CLEAN THE HEPA AIR OUTLET FILTER

  1. Press to open the air outlet cover
  2. Take out the Hepa air outlet filter.
  3. Clean the Hepa air outlet filter. Rinse it under cold running water. Dry it thoroughly before placing it back.
  4. Put back the air outlet cover after the filter is placed back.

SAUBER VCE-125693.1 Cyclone Vacuum Cleaner-5

Please note:
The Hepa filter in the cleaner will became dusty over time. This is normal and will not affect the performance of the filter. If the Hepa filter is so dusty that suction does not return to 100%, we suggest that the filter be removed then rinsed under the faucet and allowed to dry for 24 hours by airing not near the fire or some high temperature objects before refitting into the vacuum. This should be done at least every six months or when suction appears to be reduced obviously.
Note:
The suction hole must be open, free of any obstructions at all times. Otherwise, the motor will overheat and could become damaged.
If the suction power of the vacuum cleaner gets low please check the hose for obstacles. You can open the hose by pressing the square part on the hose handle. Take apart the two parts and remove any obstacles. To assemble the hose again first press the flexible hose into the handle and then click in the connection part.

Important:
All filters should be checked regularly for signs of damage, preferably after each cleaning task. The filters must be replaced immediately if they become damaged. Always disconnect the vacuum from the electrical outlet when checking the filters.

Parking:
This vacuum cleaner can be parked as below style to save your room space.

SAUBER VCE-125693.1 Cyclone Vacuum Cleaner-7

TECHNICAL DATA
Voltage: 220-240V ~ 50-60Hz Power: 800W

GUARANTEE AND CUSTOMER SERVICE
Before delivery our devices are subjected to rigorous quality control. If, despite all care, damage has occurred during production or transportation, please return the device to your dealer. In addition to statutory legal rights, the purchaser has an option to claim under the terms of the following guarantee:
For the purchased device we provide 3 years guarantee, commencing from the day of sale. If you have a defective product, you can directly go back to the point of purchase.
Defects which arise due to improper handling of the device and malfunctions due to interventions and repairs by third parties or the fitting of non- original parts are not covered by this guarantee. Always keep your receipt, without the receipt you can’t claim any form of warranty. Damage caused by not following the instruction manual, will lead to a void of warranty, if this results in consequential damages then we will not be liable. Neither can we hold responsible for material damage or personal injury caused by improper use if the instruction manual is not properly executed. Damage to accessories does not mean free replacement of the whole appliance. In such case please contact our service department. Broken glass or breakage of plastic parts is always subject to a charge. Defects to consumables or parts subjected to wearing, as well as cleaning, maintenance or the replacement of said parts are not covered by the warranty and are to be paid.

ENVIRONMENT-FRIENDLY DISPOSAL

Recycling – European Directive 2012/19/EU
This marking indicates that this product should not be disposed with other household wastes. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

Manufactured by: Emerio Deutschland GmbH
Lerchenweg 3, 40789 Monheim am Rhein, Deutschland

Hersteller:
Emerio Deutschland GmbH
Lerchenweg 3, 40789 Manheim am Rhein, Deutschland

References