Greentech CAS 500 Air Purifier User Manual

June 5, 2024
GreenTech

Greentech-CAS-500-Air-Purifier-logo

Greentech CAS 500 Air Purifier

Important information

Proper use & notes before use

Thank you for purchasing our air purifier!
In order to facilitate the installation and use of this device, we recommend reading this manual carefully and keeping it stored safely. To ensure that you always enjoy fresh air, use this manual for qualified and standardized installation, proper use, and maintenance. If any questions arise, please consult this manual. If it is in accordance with the warranty, we kindly welcome you to contact the manufacturer or retailer. This device is to be used solely for purifying ambient air in interior spaces in accordance with the safety information provided.
Warning: Please pay attention to the safety information and instructions!
Read this manual carefully prior to commissioning the device and pay attention to the safety information. This manual must be available at all times and must be carefully stored. People who use this device must have carefully read and understood this manual and must be aware of the dangers of handling electrical air purifiers.

Improper use
Do not place the device directly below the air conditioner in order to prevent condensation within the air purifier. For the same reason, the device should not be put into a room with high temperature fluctuation. Do not use this product in a humid or high-temperature environment (e.g. bathroom, toilet or kitchen). Otherwise, functioning and lifetime of the device could be affected negatively. Do not use the device as daily ventilator, dust cleaner or cooker hood. Besides, do not use this device to substitute proper ventilation as well as regular vacuum cleaning. Improper use can endanger health and life.

Safety information & instructions for use
Failure to adhere to the safety information and instructions could lead to electric shock, fire and/or other serious injuries. Retain all of the safety information and instructions for future use!

General information

  • Follow this safety information to avoid the risk of fire or electric shock.
  • Never place the device in areas exposed to rain, water, moisture or high air humidity levels. Do not place it next to a wash basin or sink.
  • Keep the packaging, e.g. the plastic film, away from children! Risk of suffocation.
  • Only use a plug socket with the stated voltage (see Section Technical information).
  • Do not use the device if the power cable or plug is damaged, or if the connection to the wall socket is unstable.
  • Do not modify, make attachments to or convert the device in any way.
  • Make sure that the power cable is not trapped during operation and cannot be damaged in any other way. Arrange the cable so that it does not pose a trip hazard.
  • Do not subject the power cable to tension.
  • Unplug the device when not in use for long periods or for cleaning, and check the connecting elements for damage prior to each use. The device must not be used in the case of damage.
  • Do not block the air inlet and outlet and do not sit on the device.
  • Do not insert your fingers into the device’s air inlet our air outlet to prevent physical injury.
  • Do not modify the device.
  • Do not use the device in rooms with an explosion risk, nor in rooms in which the air may contain fuel vapours, oil vapour, metal dust or insecticides.
  • Do not use the device to combat harmful fumes (e.g. carbon monoxide).
  • Do not use any spray cans containing flammable materials near the device.
  • Do not use any volatile liquids, petrol, kerosene, paint thinner or polish to clean the device. These substances can damage the surface of the device.
  • Use only original greentec filters specially intended for this device and do not use any other filters. Caution: Do not use the device near a smoke alarm. There might be the possibility that the smoke alarm does not work properly.
  • Avoid open fires and sparks in the room in question and never place the air purifier in direct sunlight.
  • The device must not be operated by people (including children) with reduced physical, sensory or mental capacities or with a lack of experience and expertise, unless they are being monitored and supervised.
  • Keep the device and the remote control away from children and animals. The device and its accessories are not to be used as toys.
  • Do not remove any safety notices, stickers or labels from the device and keep them in a legible condition. Do not touch the plug or the device with damp or wet hands. Otherwise, there is a threat of electric shock.

People who use this device must be aware of the dangers of handling electrical air purifiers.

In the case of emergency
Switch off the device at the control unit. Unplug the device where necessary. Do not reconnect a defective device to the power supply.

Product information
Congratulations on your purchase of a quality air purifier! The device has the following features:

  • Adjustable fan for air purification
  • Combined filter technology:
    • Synthetic pre-filter: removes large granule dust, dander, pollen, floating compound and other pollutants. Washable and reusable.
    • Cold catalyst filter: catalyses the formaldehyde, ammonia, benzene, TVOC, hydrogen sulphide and other harmful gases to work with oxygen, and then decomposes them into water and carbon dioxide. The filter itself does not undergo charges during the decomposition action. The main constituents of the catalyst are food and medicine additives. Therefore, the product is non-toxic, non-corrosive and non-inflammable. It produces only water and carbon dioxide. The cold catalyst can be used to deal with formaldehyde, ammonia, benzene, TVOC, hydrogen sulphide and other harmful gases released by plywood, furniture, wallpapers, carpets, curtains and bedspreads.
    • Honeycomb-activated carbon filter: The cellular-activated carbon carries high efficient additives. It has good absorption and dust collection characteristics.
    • Antibacterial filter: The 5-microns filter with antimicrobial agents can reduce the danger of bacteria in the air.
    • HEPA-13 filter: The precision of the HEPA filter is 0.01 micron. It is able to eliminate particles which are larger than 0.01 micron with the filtration rate of 99,95 %. Dust, bacteria, fungi, viruses, allergens and other small and tiny particles are not able to get through the HEPA filter.
  • Anion release: The ionizer releases large amounts of anions and makes the oxygen negatively charged, thus gathering the positively charged particles like floating dust, bacteria, viruses and smoke. The particles become denser and sink to the ground. The smaller the particle size, the higher the capture rate.
  • Ultraviolet sterilize light: The 245 nanometers of ultraviolet light is able to sterilize a variety of bacteria. The UV germicidal lamp is able to eliminate odour caused by smoke and mould.
  • Intelligent particle sensor system: Through the intelligent particle sensor system with its PM2.5 sensor the air purifier can automatically adjust the fan speed according to the air quality display.
  • Control panel with the following main functions: Setting fan speed; setting timer, sleep mode The device directly reduces the presence of aerosols and clouds of airborne particles where it is placed. There is a specific value for the rate of air circulation, depending on the size of the room in question, see Section Operation/control panel.
    Thanks to its features, when used correctly, the device reduces the risk of airborne infection in indoor spaces.

The deviceGreentech-CAS-500-Air-Purifier-fig1

# Designation
1 Display panel
2 Control panel
3 Front plate
4 Air inlet
# Designation
--- ---
5 Air outlet
6 Handle
7 Water tank
8 Water tank handle
Usage

Delivery scope

  • 1 x air purification device, including power cable
  • 1 x filter set wrapped in foil, located within the device
  • 1 x manual in English and German
  • 1 x remote control

Unpacking of device
Carefully remove all packaging materials on the outside of the device. If, after removing the packaging, you notice that the device is damaged, contact the manufacturer or retailer who sold you the item. Please note that warranty claims are invalidated if the damage is due to improper removal of the packaging.

Unpacking of filters

  • Open the front plate as shown on the left.
  • Take out the filters by pulling on the respective strip and remove all packaging bags from the filters. Greentech-CAS-500-Air-Purifier-fig2

Reassembly

  • Install filter 3 (HEPA-13 & antibacterial compound filter)
    Note: Please ensure the tab side is facing you.

  • Install filter 2 (activated carbon & cold catalyst compound filter)
    Note: Please ensure the tab side is facing you.

  • Install filter 1 (pre-filter)
    Note: Please ensure the handle side is facing you.

  • Carefully install front plate as shown on the left. Greentech-CAS-500-Air-Purifier-fig4

Preparation for humidification

  • Pull the water tank out from the side of the device.
    Note: Please find the exact water tank position in the Important information on the schema.

  • Take out the humidifying filter and remove the packaging from it.

  • Put the unpacked humidifying filter back into the water tank.

  • Fill about 1 litre of cold water into the water tank through the inlet. Eventually, around 80 % of the water tank volume should be filled with water.

  • After adding water, close the lid.

  • Then push the tank back into the purifier.

Note: The humidification effect is connected to the wind speed and works better when the device is operating at a higher wind speed. If the water tank level becomes low, the indicator light will flash while the device continues working normally.

Positioning of the device
This device must be placed on a dry, stable, and flat surface. Position the device in such a way that it is not touching any walls. Leave a minimum of 20 cm of free space around the device and a minimum of 30 cm of free space above the device. Otherwise, it could lead to damage or dirt on the wall or device. The rear of the device must face the wall; the front must face into the room. The front of the device can be identified by the large-scale green logo print.

Operation/control panel

Commissioning
Check the outside of the device for damage prior to every use. If you notice damage, do not switch on the device and contact the responsible retailer or manufacturer. Once the device has been set up as described in the previous chapter, you may switch it on. Greentech-CAS-500-Air-Purifier-
fig8

Remote control

The product is equipped with a remote control. The remote control comes with a coin cell type CR 2032 (3 V). If you do not use the remote control for a long period, please take out the battery.
Note: Before the first use, you need to open the battery compartment on the back of the remote control and take out the plastic cover on the coin cell.

Using the device

  • Press the power button in order to start the device. The icon is green. When pressing the power button again, the device switches to standby mode. The icon is now red.

  • When pressing this button, child lock will be activated. While active, the child lock disables all buttons and the device keeps running as set previously.
    Press the child lock button for 5 seconds to exit this mode.

  • When the device is running, the ionizer is automatically active. By pressing the ionizer button on the remote control, you can switch the ionizing function off.

  • Press this button to set the working time. Every push increases the working time by 60 minutes. You can set between 1 – 12 hours and the device is turned off when the timer expires. To exit this mode, press the button until you reach 12 hours and then press once more.

  • When the device is running, the UV lamp is automatically active. By pressing the UV lamp button on the remote control, you can switch the UV lamp off.

  • When the device is switched on, you may press the auto button in order to activate the auto mode. In this mode, the motor speed will be adjusted automatically to the degree of air pollution and both the ionizer as well as the UV lamp functions will be activated.
    Note: If you change the wind speed during the auto mode, the auto mode will be disabled.

    • speed level 1 & 2: PM2.5 = 0 – 80 | green light
    • speed level 3 & 4:PM2.5 = 81 – 120 | blue light
    • speed level 5 & 6: PM2.5 = 121 – 160 | yellow light
    • speed level 7 & 8: PM2.5 = 161 – 500 | red light
  • 5 seconds after pressing the sleep button, the device switches to sleep mode. The lights will be turned off and the device switches to the lowest speed level.
    Press any button to wake the device up. Then press the sleep, speed –, speed + or auto button in order to quit sleep mode.

  • Press this button to switch to the next speed level. The speed control can be set to 8 different speed levels. When pressing the button while the highest level is active, the speed will switch to the lowest level again.
    Note: If you use the speed button, auto mode will be disabled.

  • While the device is switched on, press this button in order to see the accumulated working time on the display. Since the screen can only display three digits, the thousands of digits will be displayed first, then hundreds, tens and single. Please read them together. If a filter replacement was put through, this button needs to be pressed for 5 seconds in order to reset the working time. For more information, see chapter Maintenance.

  • To connect the device to your app, see chapter Operation via the app.

  • This device is light-sensitive. It will automatically switch to sleeping mode 2 minutes after the surrounding light decreases by 5 times compared to the light level before. The device will quit sleeping mode 3 minutes after the surrounding light increases by 5 times and will then continue working in auto mode.

Switching off the device
When pressing the power button while the device is running, it will switch to standby mode. The icon turns red.

Operation via app
Scan the QR-Code and download the “Smart Life“ app (suitable for iOS- and Android).

  • Either log in to your existing account or sign up for a new one.
  • Now choose „Add Device“.

Greentech-CAS-500-Air-Purifier-fig16

  • Choose the category “Small Home Appliances“ and then select “Air Purifier (Wi-Fi)“. Greentech-CAS-500-Air-Purifier-fig17
  • while the device is turned off (standby), press and hold the WiFi button till a sound rings and the WiFi symbol is flashing slowly. Use the app to type in your WiFi password and confirm it with the “Next“ button.  Greentech-CAS-500-Air-Purifier-fig18
  • Is the WiFi symbol on the display flashing slowly? Then press the “Next“ button again. Greentech-CAS-500-Air-Purifier-fig19
  • Wait for the configuration to be completed.  Greentech-CAS-500-Air-Purifier-fig20
  • The configuration is almost completed. Greentech-CAS-500-Air-Purifier-fig21
  • The air purifier was added successfully. You can rename and control it through the app. Greentech-CAS-500-Air-Purifier-fig22

Maintenance and disposal

Troubleshooting
The device is inspected in detail to ensure it works correctly prior to dispatch. Should faults occur despite this, please check the device for the following points (based on the relevant issue).

Problem Solution
No air comes out from the outlet Please check whether the device is turned on

and connected to the power supply.


Outlet airflow is significantly weakened

| The filters are dirty and they need to be cleaned or replaced. You can slightly shake the filters to remove the dust and other objects on it.
The filter packaging bag is not removed. Please remove the filter packaging bag.


The air quality has not been significantly improving after long running time

| Open the window and let some fresh air into the room.
Check the filter layers installation sequence.
Check if filters are dirty and replace them if necessary.


Power is down and/or cut off suddenly

| Check if the case is properly shut and close it properly if necessary.
Open the window and let some fresh air into the room.
A creaking or banging sound comes from the running device| Check if the ionizer needs to be cleaned. For cleaning, follow the instructions in chapter Cleaning.
Display panel shows ‘F1’ or ‘F2’| Turn off power immediately and contact the customer service.
Air purifier randomly switches to sleep mode| Disable auto mode.

The device does not work properly despite carrying out the checks recommended above Contact customer service or the retailer who sold you the device.

Cleaning

Clean air inlet & outlet

Prior to every commissioning and where needed:
Check the air inlet and air outlet for dirt and foreign bodies and clean if necessary. Do not exude any pressure on the device to do so. Use suitable cleaning tools where required. Clean the air outlet as described below:

  1. Switch off and unplug the device from the socket. Do not touch the plug or the device with damp or wet hands. Otherwise, there is a threat of electric shock.
  2. Put the hand on the air outlet grille and pull it up as illustrated below.  Greentech-CAS-500-Air-Purifier-fig23
  3. Wipe the air outlet area with a dry, soft cloth and carefully remove any foreign bodies that may have gotten into the air outlet.
  4. Close the air outlet grille again by gently pushing it down.

Clean casing
Whenever necessary, clean the outside of the device in order to prevent dust from collecting.

  1. Switch off and unplug the device from the socket.Do not touch the plug or the device with damp or wet hands. Otherwise, there is a threat of electric shock.
  2. Gently wipe the surface of the device with a damp cloth

Clean pre-filter (filter 1)
Every 320 hours of operation, the ‘RESET’ icon will flash on the display panel, which means that the pre-filter (filter number 1) needs to be cleaned. If the air purifier is used in a dusty environment, the pre-filter may need to be cleaned more often. Clean the pre-filter as instructed below:

  1. Switch off and unplug the device from the socket. Do not touch the plug or the device with damp or wet hands. Otherwise, there is a threat of electric shock. Wear gloves and a mask! Otherwise, there is a risk of exposure to contamination, viruses, bacteria, and similar potential hazards.
  2. Open the front plate and take out the pre-filter (number 1) as shown in the chapter Installation.
  3. Clean the surface of the pre-filter with a vacuum cleaner running at minimum power. If necessary, use some water to clean the pre-filter more thoroughly.
  4. Let the pre-filter dry thoroughly.
  5. Put the dry filter back into the casing and close the front plate as shown in the chapter Installation.
  6. Then connect the device to the power supply and press the ‘RESET’ button on the control panel for 5 seconds in order to confirm the cleaning of the pre-filter and to reset the counter.

Clean particle sensor
Every two months, clean the particle sensor to prevent clogging. If the air purifier is used in a dusty environment, the particle sensor may need to be cleaned more often.

  1. Switch off and unplug the device from the socket. Do not touch the plug or the device with damp or wet hands. Otherwise, there is a threat of electric shock.
  2. The particle sensor is located on the left side of the device. As illustrated below, the sensor is exposed by pulling the small latch of the particle sensor cover to the left and pulling the same out while still holding the latch. Now use a dry cotton swab to clean the exposed particle sensor area. Greentech-CAS-500-Air-Purifier-fig25
  3. When finished, put the particle sensor cover back to its original position.

Clean ionizer
When the device emits a creaking sound while running, clean the ionizer area in order to ensure its proper functioning.

  1. Switch off and unplug the device from the socket. Do not touch the plug or the device with damp or wet hands. Otherwise, there is a threat of electric shock.
  2. Put the hand on the air outlet grille and pull it up as illustrated below.  Greentech-CAS-500-Air-Purifier-fig26
  3. The position of the ionizer is beneath a grid that only becomes visible after removing the air outlet grille, as shown on the illustration below. Using the control panel as an orientation, the ionizer is located in line with the ‘SLEEP’ button. 
  4. Use suitable cleaning tools where required, e.g. vacuum cleaner with brush attachment at minimum power, to remove dust from the air outlet and the area beneath. Do not exert too much pressure on the device, especially on the grid.
  5. Close the air outlet grille again by completing the steps from before in reverse order.

Maintenance

Replacing the pre-filter (filter 1)
Every 2 years, it is recommended to replace the pre-filter.

  1. Switch off and unplug the device from the socket.
  2. Open the front plate as described in the chapter Installation.
  3. Now carefully extract the pre-filter (number 1) as described in the chapter Installation.
  4. Put the replacement filter into the device in the same position as the old filter. The number needs to be upfront and the right way round so that it is readable.
  5. Again, complete the respective steps described in the chapter Installation in order to close the front plate properly.
  6. Dispose of the used filter in your domestic waste.

Replacing the main filters (filters 2 & 3)
Every 1500 hours of operation, the ‘RESET’ icon will light up and remain lightened, which means that both filters 2 and 3 need to be replaced. The filters may need to be replaced in shorter intervals when there is a higher level of dirt in the air as usual. Dirty filters inhibit the performance of the device. Errors that arise when filters needs to be replaced are described in chapter Troubleshooting.

  1. Switch off and unplug the device from the socket. Do not touch the plug or the device with damp or wet hands. Otherwise, there is a threat of electric shock. Wear gloves and a mask! Otherwise, there is a risk of exposure to contamination, viruses, bacteria and similar potential hazards.
  2. Open the front plate as described in the chapter Installation.
  3. Now carefully extract the filters. Greentech-CAS-500-Air-Purifier-fig29
  4. Put the replacement filters into the device in the same order as before extraction. There are numbers and direction instructions on the filters.
  5. Again, complete the respective steps described in the chapter Installation in order to close the front plate properly.
  6. Put the used filter into the remaining bag of the new filter, seal the bag and immediately dispose of it in your domestic waste. If you notice that any of the parts on or in the device not listed here are missing or damaged, please contact your local retailer or manufacturer.
  7. Then press the ‘RESET’ button on the control panel for 5 seconds in order to confirm the replacement of the filters and to reset the counter.

Storage
The following storage conditions must be ensured when the device is not in use:

  • Take the batteries out of the remote control and store the batteries separately from the remote control.
  • Unplug the device before storing it.
  • Clean the air purifier and particle sensor as explained in the chapter Cleaning. Let all parts dry thoroughly before moving to the next step.
  • Store the device in a cool and dry place and protect it from both heat and frost.
  • Cover the device with a cover or cloth. Ensure that the device is not connected to a plug socket before covering it.
  • Before using the device again, check the condition of the power cable. If in doubt, contact customer services about the condition of the cable.

Disposal (Life-Cycle Service)
As with other electrical and electronic devices, this device must not be disposed of in domestic waste due to the symbol showing a crossed-out waste bin. Here at Greentech, we want to promote the reuse of recyclable materials. As part of our Life-Cycle Service, we check the recycling options of old materials in our production chain. Please visit our website at www.GreenTech.ag for more information about options and locations for returns. Help us to improve the recycling of old devices and to avoid negative consequences for the environment and human health by disposing of your device properly at the end of its lifespan or returning it to us!

Appendix

Technical information

Size: 401 x 232 x 662 mm
Weight: 11,3 kg
Flow rate: Max. 488 m³/h
Connection: 230 V
Rated frequency: 50 Hz
Rated power: 85 W
Nominal current: ~ 0,37 A
Sound pressure level: Between 31,9 and 57,6 dB(A) at a distance of 1 m

Declaration of Conformity

This is a simplified Declaration of Conformity:
Hereby, Greentech AG declares that the air purifier type CAS 200/ CAS 350/ CAS 500/ CAS 600 and CAS 800 comply with the 2014/35/EU Low Voltage directive, 2011/65/EU and 2015/863/EU RoHS directive, 2014/30/EG EMV Electromagnetic compatibility directive as well as applied harmonized standards, in particular EN 60335- 1, EN 60335-2-65, EN 62233, EN 55014-1, EN 55014-2, EN IEC 61000-3-2, EN 61000-3-3, IEC 60335-2-65, IEC 60335-1, EN ISO 13857.
The full and latest version of the Declaration of Conformity is available on our website: www.GreenTech.ag.

Order parts or accessories

If any parts need to be replaced or if you require additional parts, please visit our website: www.GreenTech.ag in order to access information about replacement and additional parts. If any problems occur, please contact our customer service. The contact information is available on our website: www.GreenTech.ag.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals