DIGITAL LOGGERS LPC-3 Web Power Switch III User Guide
Web Power Switch III Features
Congratulations on your purchase. The Web Power Switch III is a cost- effective AC power switch for remote control and reboot.
Web Interface
The internal web server is configured and controlled from any standard
browser. Enter the IP address in the browser URL line.
8 Switched Outlets + 2 Un-switched Outlets
Eight control circuits are provided, each with a switched outlet. Two un-
switched outlets power “always on” devices. Line voltages from 90-240VAC
voltage are detected automatically. A circuit breaker and power sequencing are
provided.
Security: Password, Movable HTTP Port and Subnet Restriction Password security limits access to the switch. A changeable HTTP port makes the switch virtually impossible to access without knowing your custom URL. Subnet restriction limits control to your LAN.
Sequenced “On Timer”
A programmable delay timer allows outlets to be switched on in sequence,
rather than simultaneously. Most electrical devices draw more power when
initially switched on. Using the timer, more equipment can be attached without
overload.
New Features, Flash Firmware Upgrades
Upgrade via Ethernet as new features become available. Scripting, Syslog,
and AutoPing features have been added to your unit.
At DLI, we listen to customers. Please send your suggestions to engineering@digital-loggers.com Since we’re constantly adding and changing features, specifications are subject to change without notice.
Product Features
The factory installed options in the Web Power Switch III are:
- Internal Auto-Ping to automatically monitor servers
- BASIC Scripting Language
- Syslog Reporting
- Internal high-current MOV Surge Protection
User installable options are:
- Rack Mount Bracket $19.
These features and this manual apply to the third upgraded version of this
product, P/N LPC3. For early units, download:
www.digital-loggers.com/lpcman.pdf
Important Factory Defaults
Default IP Address
The factory default IP address is 192.168.0.100
Default Login
User name; admin (lower case) Password: 1234
To reset the IP address and login to defaults:
- Switch the unit on
- Gently depress the reset switch with a pen for 2 seconds.
- The OUTLETS ON and REMOTE ACCESS lights will flash.
Note: This resets the admin login and IP, but not outlet names and links.
Quick Setup
Use these shortcuts if you are an experienced installer. Please read the manual if this is your first web-accessible product.
- Connect to your LAN Using a straight RJ-45 cable. Make sure the 192.168.0.100 address is compatible with your LAN, otherwise use a crossover cable directly to your PC.
- Switch the web power switch on.
- Enter 192.168.0.100 in your web browser address bar. If the login page doesn’t appear, follow the network setup instructions.
- Login using the default user name, admin (lower case). Enter the default password, 1234
- Use the setup page to add outlet names or change the IP address.
- Set the recovery mode for safety after a power failure.
- Change the password for improved security.
Tip: A lamp, outlet tester, or small appliance is handy for testing the switch. This ensures that the switch has been configured properly before attaching equipment.
Windows IP Setup
(2000, 2003, 2008, XP, Vista, W7)
If your default Windows settings won’t access the switch IP, use a crossover cable and follow these steps to configure Windows.
- Before adding an IP, close network programs and browsers. Go to the Network Settings – Local Area Network.
- Use the keyboard shortcut
– type “ncpa.cpl” Click OK. - Right click on your LAN connection and choose “Properties”. Highlight “Internet Protocol” and click the “Properties” button.
- Click the “Advanced” button. Under the IP Address settings, click “Add”
- Enter a new IP, such as 192.168.0.10, and a subnet mask of 255.255.255.0. Press the “Add” button. This new IP is added the list.
- Close all windows and restart your browser for the Windows IP configuration to take effect.
Type 192.168.0.100 in the browser URL line. The login page should now be displayed. The default user name is: admin (lower case) and password: 1234
Basic Operation
After power-up, the switch performs a sequence of self-tests to ensure reliability. After self-test, an internal web browser starts using the fixed (static) IP address selected on the setup page. The switch may then be operated via a web browser. To access the switch, simply enter the IP address in the URL field of your web browser. Click on the control page to switch circuits on and off.
Home (Outlet Control) Page
To access the home page, first enter the IP address in web browser URL field, then log in. The home page contains links to other pages. The first four are static links:
Outlet Control
Clicking “Outlet Control” links to the home page used for manually switching
outlets on and off. Access to specific outlets is determined by your login.
Settings
Clicking “Settings” links the administrator to a configuration page. This page
is used to set outlet names, power on features, network settings, user
information and passwords.
Help
The Help link displays the latest online manual. Since features are subject to
change without notice, this manual may not be a perfect match for your switch,
but the later manuals will include all legacy features.
Logout
Logout ends the web session. A login is required to reconnect.
Programmable Web Links
Four additional user-defined web links are provided on the outlet control
page. Factory defaults are “Link 1”, “Link 2”, etc. You may change the name
and destination URL for these links on the “Setup” page. These links are
convenient for connecting to other power switches or to remote sites.
Switching Outlets on and Off
The outlet control page lets you control any switched outlet, but not the
always-on pair. The sequence delay in which outlets will be switched on is
determined by settings on the setup page. To switch an outlet on or off,
simply click to the right of the outlet name or number. Switching is
immediate.
You may also “Cycle” a device which is connected to the switch. This feature
is useful for rebooting Ethernet devices which may interrupt the web link to
the switch. Clicking “Cycle” switches power off, waits a few seconds, and then
switches power back on.
This resets the attached device. You may also “cycle” all outlets using the
“Cycle all outlets” button on the bottom of the page.
Depending on your web browser settings, you may need to click the “refresh” button to update the on-screen status display after changing settings. Most browsers update automatically after one minute.
Setup Page
The settings page allows the administrator to configure the power switch. These settings are supported:
Switch and Outlet Names
Use the switch name fields to assign a Switch Name to the power switch itself.
Examples are “Server Rack Power Strip”. The Switch Name field appears on the
top of the home page. Assign a separate name to each outlet, such as “Linksys
Router” or “Email Server” to make identification of each circuit simple.
Power-On Sequence Delay
When a time value is entered in the “All ON sequence delay” field, the power
switch will pause for a period of time before switching each outlet on in
sequence. This delay helps prevent the power surges and blown circuit breakers
which can occur when multiple devices are switched on simultaneously. A delay
of 60 seconds is suggested for server applications.
You may also enter a screen refresh delay. If “Enable screen refresh” is checked, and a delay value is entered, your browser should periodically update the status screen.
Power Loss Recovery Modes – IMPORTANT SAFETY SETTINGS
The power loss recovery mode setting has three settings which take effect
after a power failure:
1. You can turn all outlets off (all systems will be switched off until
manually turned on later) by checking the first box.
2. You can automatically turn all outlets on using the “All ON sequence
delay” described above. Check the second option to do this.
3. You can return to the same outlet settings that were used prior to the
power loss. The “All ON sequence delay” will also be used in this instance.
User Defined Web Links
You may link to other power switches, your own web pages, or remote web
sites by entering up to four URLs and descriptions in the Setup page. For
example, enter “Site Two Power Switch” in the description field with a URL of
“192.168.0.102”. These links appear on all pages.
Network Settings
A fixed IP address, network mask, gateway, and subnet mask must be entered in
these fields. When changing IP addresses, you may need to restart your network
switch to validate the new IP on an “auto-configuring” switch port. Be sure to
record the new IP address.
Status LEDs
Power LED
The power LED illuminates when the main power switch is turned on. This
indicates that there is power to the main (unswitched) outlets and to the web
server.
Outlets ON LED
The Outlets ON LED is off when all outlets are switched off and none of them
is going to be switched on during delayed sequence. The LED blinks once for
each outlet switched on according to the following graph:
Remote Access LED
The Remote Access LED lights when a non-expired login session exists. The
light goes out after all users log out or after 30 minutes of inactivity. This
LED also blinks to display any network activity.
Security Settings
Your switch employs JavaScript encryption and secure challenge response authentication. This gives it good out-of-the box security. Adding additional security takes just a moment:
Changing the Password
It’s a good idea to change your password for better security. Change it on the
setup page, and write it down in a safe place. Use
a JavaScript enabled browser.
Restricting Subnet Access
To restrict access to your local LAN, or “Class C ”, check the subnet
access setting on the setup page.
Changing the HTTP Port
Changing the HTTP port makes it almost impossible for a hacker, even one
with your password, to find your switch.
Installing Inside a Firewall
Install your switch inside a firewall, rather than directly on the
Internet for an additional layer of security.
AutoPing – Automatic Monitoring and Reboot
The Web Power Switch III includes a powerful automatic reboot feature.
AutoPing automatically reboots non-responsive servers. Learn more at:
www.digital-loggers.com/autoping.html
Scripting – Internal Programming Language
An internal machine control language styled after the BASIC programming
language can be used to automate power switching.
Find sample scripts and learn more at:
www.digitalloggers.com/scripting.html
Program Control via Perl
The switch can be easily controlled from your application or a command line
using a PERL script. Download a sample:
www.digital-loggers.com/lpcperl.txt
Syslog Event Reporting & Logging
One or more switches can be set to report event logs to a central Syslog
server. Download a Syslog server & learn more:
www.digital-loggers.com/syslog.html
Limited One Year Warranty
The terms of this warranty may be legally binding. If you do not agree to the terms listed below, return the product immediately in original unopened condition for a full refund. The purchaser assumes the entire risk as to the results and performance of the unit. DLI warrants this power switch to be free from major defects. No agency, country, or local certifications are included with this unit. It is the responsibility of the user to obtain such certifications if they are necessary. DLI’s entire liability and exclusive remedy as to defective hardware shall be, at DLI’s option, either (a) return of the purchase price or (b) replacement or repair of the hardware that does not meet DLI’s quality control standards and has been returned through proper RMA procedures. DLI’s liability for repair or replacement is to DLI’s customer ONLY. WARRANTY SERVICE DOES NOT INCLUDE SOFTWARE OR HARDWARE UPGRADES. No warranty service will be provided without an original invoice from DLI and an RMA number provided by technical support. RMA material must be shipped prepaid to DLI. RMA numbers are valid for 15 days from date of issue. This warranty does not cover products modified, subjected to rough handling, or used in applications for which they were not originally intended. No oral advice or verbal warranties made by DLI’s employees, dealers, or distributors shall in any way increase the scope of this warranty. DLI makes no warranty as to merchantability or fitness for any purpose. Voltage and current ratings and applicable uses vary from country to country. DLI assumes no liability for incidental or consequential damages arising from the use or inability to use this product. This warranty gives you specific legal rights. You may also have other rights that vary from state to state. Since some states do not allow the exclusion of liability for consequential damages, some of the above limitations may not apply to you.
DIGITAL LOGGERS, INC.
2695 Walsh Avenue
Santa Clara, CA 95051
FAX 408-541-8459
www.digital-loggers.com
© 2006-2011 DLI US & Foreign Patents Pending
Release 1.4.3 Printed June 8, 2010 THANKS SINFO!
References
- Washington Contract Loggers Association, Inc.
- Smart Power Control and Logging - Free Trial!
- Reliable Automatic Power Reboot - AutoPing!
- digital-loggers.com/lpcperl.txt
- BASIC power control scripting language
- Reliable Automatic Power Reboot - AutoPing!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>