GoGEN ME 3257 Weather Station User Manual
- June 5, 2024
- Gogen
Table of Contents
GoGEN ME 3257 Weather Station
MAIN FUNCTIONS
- Radio Controlled Time DCF77; 77,5 kHz, 12/24 format hour time display
- Dual alarms, Snooze function (snooze interval optional from 3 minutes to 20 minutes, default: 5 minutes)
- °C/°F switch over
- 6 level of weather forecast display
- Indoor temperature range: 0 ~ +50°C, tolerance: ±1°C
- Indoor humidity range: 25% ~ 95% tolerance: ± 5%
- Outdoor temperature range: -35~60°C, tolerance: ±1°C
- Outdoor humidity range: 25% ~ 95%, tolerance: ± 5%
- Temperature alert for both highest and lowest indoor and outdoor temperature
- RF RF 433,94 MHz (ERP = 10 mW) outdoor temperature and humidity display, up to 3 outdoor sensors’ receivable
- Built-in barometer
- Comfort level display
- Adjustable backlight (High light, mid-bright, turnoff)
- Backlight function (light on for 8 seconds when powered by batteries)
MAIN UNIT APPEARANCE
- A1 Outdoor temperature
- A2 Weather forecast
- A3 Comfort indicator
- A4 Indoor temperature
- A5 Sensor channel
- A6 Date / Time
- A7 Outdoor temperature alert
- A8 Outdoor humidity
- A9 Indoor temperature alert
- A10 Indoor humidity
- B1 Wall Mount Hole
- B2 Adaptor Input
- B3 Battery Cover
KEY FUNCTION
C1 DOWN BUTTON
Under time mode, press “DOWN” key to switch 12/24H display.
Under time, calendar, temperature alert, snooze mode, press “DOWN” key to go
back one step, press and hold “DOWN” key for some seconds to go back 8 steps
per second.
Under temperature alert mode, press “DOWN” Key to turn alert on/off.
Under normal mode, press “DOWN” key for some seconds to RC Receiving. Under
DCF77 receiving, press “DOWN” key to exit.
C2 MODE BUTTON
Under normal mode, Press “MODE” key to switch the current time→ AL1→ AL2
(cycle display)
Under current time mode, press and hold “MODE” key for 3 seconds to enter
setting, the setting in sequence: time zone → hour → minute → year → month day
→ week day language→ exit
Under AL1 mode, press and hold “MODE” key for 3 seconds to enter alarm 1
setting in sequence: AL1 hour→AL1 minute →exit Under AL2 mode, press and hold
“MODE” key for 3 seconds to enter alarm 2 setting in sequence: AL2 hour→AL2
minute →exit
C3 SNOOZE/LIGHT BUTTON
Under normal mode, press “SNOOZE/LIGHT” key to adjust backlight.
Adjust in sequence when powered by adapter:
Highlight → mid-light → turn off→ High light (cycle setting) Adjust in
sequence when powered by batteries: Highlight→ mid-light → high light (cycle
setting)
Under alarm mode and normal mode, press “SNOOZE/LIGHT” key for some se-conds to enter snooze interval setting, default interval 5minutes, optional setting from 3 minutes to 20 minutes. When alarm is up, press “SNOOZE/LIGHT” key to turn on snooze.
C4 CHANNEL BUTTON
Under normal mode, press ”CHANNEL” key to switch CH1,CH2, CH3 or cycle channel
display, press and hold “CHANNEL” key for some seconds to enter register
status for outdoor temperature.
C5 UP BUTTON
Under time mode, press “UP” key to switch °C/°F display.
Under time, calendar, temperature alert, snooze mode, press “UP” key to go
forward one step, press and hold “UP “key for some seconds to increase 8 steps
per second. Under temperature alert mode, press “UP” key to turn alert on/off.
C6 ALERTS BU TTON
Under time mode, press “ALERTS” key to check temperature alert for both
highest and lowest indoor and outdoor temperature, checking in sequence:
highest outdoor temperature→ lowest outdoor temperature→ highest indoor
temperature →lowest indoor temperature (cycle display)
Under time mode, press and hold “ALERTS” key for some seconds to enter
temperature alert setting for both highest and lowest indoor and outdoor
tempe-rature, the setting in sequence: outdoor highest temperature→ outdoor
lowest temperature→ indoor highest temperature→ indoor lowest temperature→
Exit
C7 ALARM BUTTON
Under time mode, Press “ALARM” to turn on/off the alarm in sequence:
AL1 ON→AL2 ON→AL1 and AL2 On→AL1 and AL2 Of
GETTING STARTED
Main Unit – Remove battery compartment door and insert 3pcs AAA size battery.
Or connect the power cord to the wall outlet. Before connecting the unit to
power, please make sure your local voltage is the same as marked on the
adaptor. Outdoor Sensor – Batteries compartment of sensor is locating behind
the back cover, insert 2pcs AAA batteries observing polarity [“+” and “−”
marks].
OPERATION INSTRUCTION
TIME SETTING
Under time mode, press and hold „MODE“ for some seconds to enter setting in
sequence: Time zone → Hour→ Minute→ Year→ Month→ Day→ week day language→ exit
Setting item twinkling at 1HZ frequency.
After setting, press „MODE“ to exit.
No any key press for 10 seconds exit setting status, the value keep on.
Under AL1 or AL2 Mode, no any key press for 10 seconds, it will go back time
display.
ALARM SETTING
Under normal mode, press „MODE“, switch to AL1 or AL2 display:
AL1 default time 6:00am, AL2 default time 0:00am
Under AL1 Mode, press and hold „MODE“ for some seconds to enter AL1 setting.
Setting in sequence: AL1 Hour→AL1 Minute →Exit
Setting item twinkling at 1HZ frequency.
After setting, press „MODE“ to confirm and exit.
No any key press for 10 seconds exit setting status, the setting saved.
AL2 Setting is the same as AL1 setting.
ALARM ON/OFF
Under time mode, press „ALARM“ to turn on/off the alarm in sequence:
AL1 ON→AL2 ON→AL1 and AL2 ON→AL1 and AL2 OFF
When alarm is turn on and when time is up, it alarms, during alarming,
press„SNOOZE/LIGHT“ key to turn on snooze, symbol and corresponding alarm
twinkling all the time; press any other key to stop the alarm and exit the
alarm. No any key pressed, alarm stops automatically after 2 minutes.
During alarming, corresponding AL character twinkling on the display.
Under snooze mode, corresponding AL character and Snooze symbol twinkling
display. Press “SNOOZE/LIGHT” to turn on backlight for 8 seconds, press any
other key to stop and exit, at the same the alarm is off.
When alarm or snooze working, in case of DCF77 receiving time is out, DCF77 receiving would be put off until the alarm or snooze finished.
If alarm time is same for both AL1 and AL2, only AL1 symbol twinkling on dis-
play when time is up.
When one alarm time or snooze time is out, during alarming, it happens to meet
another alarm, then the first alarm would stop and work out new alarm.
Snooze could be repeated all the time. BUZZER for 2 minutes in alarm format
0-10 second: BI per second
10-20 second: BIBI per second
Over 20 seconds : BIBIBIBI per second
SNOOZE INTERVAL SETTING
Under normal mode, press “SNOOZE/LIGHT” key for some seconds to enter snooze
interval time setting (optional from 3 minutes to 20 minutes, default:5
minutes).
Snooze Interval Time Setting Display
Setting snooze item twinkling at 1Hz frequencyAfter setting, press „MODE“ to exit.No any key press for 10 seconds exit setting status, value keep on.
TEMPERATURE AND HUMIDITY FUNCTION
Out of the indoor and outdoor temperature display, the low end displays “LL”,
the high end displays “HH”.
Under normal mode, press “CHANEL” key to switch outdoor temperature and
humidity display, switch in sequence: CH1 temperature and humidity→ CH2
temperature and humidity→CH3 temperature and humidity→ CH1 temperature and
humidity (cycle display, symbol appears on the LCD display)
Under normal mode, press and hold “CHANEL” key for some seconds, clear the
outdoor temperature and humidity, then re-register for 3 minutes.
Under cycle display mode, no register no display, directly jump to registered
channel display.
Under normal mode, press “UP” key to switch temperature unit (°C or °F)
TEMPERATURE ALERT SETTING
Under time mode, press “ALERTS” key to check temperature alert for both
highest and lowest indoor and outdoor temperature.
Under temperature alert mode, press “UP” key or “DOWN” key to turn alarm
on/off. After Alarm On, corresponding alarm symbol will display.
Under time mode, press and hold “ALERTS” key for some seconds to check
temperature alert both highest and lowest outdoor and indoor temperature in
sequence: highest outdoor temperature→ lowest outdoor temperature→ highest
indoor temperature→ lowest indoor temperature→ exit
Indoor temperature upper limit: 50°C, low limit: 0°C. Outdoor temperature
upper limit: 70°C, low limit: -40°C. Setting item twinkling at 1HZ frequency.
After setting, press „ALERTS“ to confirm.
No any key press for 10 seconds exit automatically setting status.
WEATHER FORECAST FUNCTION
6 levels of weather forecast display:
sunny, sunny and cloudy, cloudy, rainy, stormy and snowy.
Barometer testing interval: 60 minutes
Dynamic weather forecast display
DCF77 RECEIVING FUNCTION
After power on or reset, after testing temperature and humidity start
receiving RF for 3 minutes automatically.
Press and hold “DOWN” key for 2 seconds to enter into DCF77 receiving. Daily
auto receiving – DCF77 receiving automatically at 1:00AM, 2:00AM, 3:00AM
everyday, if fail to receive RC until 3:00AM, then will try again at
4:00am or 5:00am.
Radio receiving signals:
Under receiving mode, DCF77 symbol twinkling at 1HZ.
When signal received, DCF77 symbol and parabolic antenna twinkling at 1HZ,
when signal received successfully, DCF77 symbol display still on the LCD
display.
When the signal is weak and cannot be distinguished, DCF77 symbol twinkling at
1HZ.
When the signal received, the signal displayed and exit the receiving.
During signal receiving, press „DOWN“ key to exit radio signal receiving.No
effective functions if other keys pressed.
Receiving time is 1:00am of the next day in case the receiving failed.
During receiving, it will switch to alarm in case of there’s any.
When DCF77 symbol displayed, if time is re-set , DCF77 symbol will shut down.
OTHER FUNCTIONS
If powered by batteries, press any key or by sound controlled, backlight on
for 8 seconds.
If powered by the adapter, shut down sound controlled, press “SNOOZE/LI-GHT”,
adjust backlight: Highlight→ mid-light→ Shutdown→ mid light→ Highlight (cycle
in sequence).
If powered by the adaptor, shut down backlight, when alarm is up the backlight
on at the same time, and backlight is off after alarm.
If powered by batteries, please change the batteries in case of dim display.
WE RESERVE THE RIGHT TO CHANGE TECHNICAL SPECIFICATIONS.
WARNING: Do not use this product near water, in wet areas to avoid fire or injury of electric current. Always turn off the product when you don’t use it or before a revision. There aren’t any parts in this applian-ce which are reparable by consumer. Always appeal to a qualified authorized service. The product is under a dangerous tention.
TO AVOID DANGER OF SUFFOCATION, KEEP THE PLASTIC BAG AWAY FROM BABIES AND CHILDREN. DO NOT USE THIS BAG IN CRIBS, BEDS, CARRIAGES OR PLAYPENS. THIS BAG IS NOT A TOY.
Disposal of old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with separate collection systems)
This symbol on the product or on its packaging indicates that this product
shall not be treated as household waste. Instead it shall be handed over to
the applicable collection point for the recycling of electrical and electronic
equipment. By ensuring this product is disposed of correctly, you will help
prevent potential negative consequences for the environment and human health,
which could otherwise be caused by inappropriate waste handling of this
product. The recycling of materials will help to conserve natural resources.
For more detailed information about recycling of this product, please contact
your local Civic Office, your household waste disposal service or the shop
where you purchased the product.
Hereby, ETA a.s. declares that the radio equipment type ME3257 is in complian-
ce with Directive 2014/53/EU. The full text of the EU declaration of
conformity is available at the following internet address:
http://www.gogen.cz/declaration_of_conformity
Charging adapter
|
---|---
Charging adapter
A
| Manufacturer’s name or trademark, business registration number
and address
| Hua Xu Electronics Factory 91441900345342145H
Room 103,No.200,Shijie Technology East Road,Shijie
Town,Dongguan City,Guangdong,P.R.China
B| Model identifier| HX12R-0501200-AG
C| Input voltage| 100-240 V
D| Input frequency| 50/60 Hz
E| Output voltage| 5 V
F| Output current| 1,2 A
G| Output power| 6 W
H| Average efficiency in active mode| 79,34 %
I| Low load efficiency (10%)| –
J| Power consumption without load| 0,047 W
References