KRAMER AFM-20DSP-AEC 20-Port Audio Matrix User Guide
- June 5, 2024
- Kramer
Table of Contents
AFM-20DSP-AEC Quick Start Guide
https://de2gu.app.goo.gl/eibH3igKhyjKxEjy5
This guide helps you install and use your AFM-20DSP-AEC for the first time.
Go to www.kramerav.com/downloads/AFM-20DSP-
AEC to download the latest
user manual and check if firmware upgrades are available.
Step 1: Check what’s in the box
- AFM-20DSP-AEC 20 Port Audio Matrix
- 1 Power cord
- 1 Set of rack ears
- 4 Rubber feet
- 1 Quick Start guide
Step 2: Get to know your AFM-20DSP-AEC
# | Feature | Function |
---|---|---|
1 | STATUS LED | Indicates the system’s status: |
•3 cycles of red/blue/off/green LEDs
• Flashes green when the application starts.
that flash in sequence for 30 seconds
• Stays green when system is ready for use.
when the system starts up, and the
application has not been launched.
2| PORTS LEDs (1 to 20)| Indicate the port’s status:
•Green when an input signal is
• Red when in clipping state.
detected, and the port is defined as
• Yellow when in limiting state. line in.
•Off when there is no signal on the input.
•White when defined as line out.
•Blue when defined as mic in.
3| IN OUT Dante TM LEDs (1 to 4)| Indicate the Dante’s signal status:
•Green when a signal is detected.
• Yellow when in limiting state.
•Red when clipping occurs.
• Off when no signal is detected.
4| HDMI LEDs| EMBED| Turns green when an analog audio signal is associated
with the HDMI OUT signal. Otherwise, it stays OFF.
DE-EMBED| Turns green when the HDMI IN audio signal is detected. Otherwise, it
stays OFF.
5| IN OUT USB or S/PDIF LEDs| Indicate the USB or S/PDIF’s status:
•Green when a signal is detected.
• Off when no signal is detected.
If a signal is detected on one channel, either left only or right only, the
status LED is green.
6| CH 1(L)/CH 2(R) AMPLIFIER LEDs| Indicate the amplifier’s signal status:
•Green when a signal is detected.
• Off when no signal is detected.
On the web page, CH1 and CH2 are referred to as AMP 1 and AMP 2, respectively.
# | Feature | Function |
---|---|---|
7 | PORTS 3-pin Terminal Block Connectors (1 to 20) | Interchangeable balanced |
mono-audio ports. Connect to an audio source or acceptor in 1 of 8 selectable
I/O configurations: 16×4, 14×6, 12×8, 12×8 AEC ,10×10, 8×12, 6×14, 4×16.
Define each port as line in, mic in, mic + 48V in, or line out.
8| USB| AFM-20DSP-AEC can process the USB audio as a stereo speaker or operate
as an audio line-in or microphone for an audio recorder application or call
conferencing.
When the AFM-20DSP-AEC is connected to a computer via USB-B:
•In the computer’s Settings > Manage sound devices > Output devices, the
AFM20DSP-AEC USB shows as “Speaker USB AUDIO CODEC”.
•In a computer recoding application, the audio input settings for AFM-20DSP-
AEC show as ‘tine USB AUDIO CODEC”.
Important:
•The computer’s “Output” device (such as speakers) shows in the AFM-20DSP-AEC
embedded web pages as a USB Digital “Input”.
•The computer’s “Input” device (such as a microphone) shows in the AFM-
20DSPAEC embedded web pages as a USB Digital “Output”.
9| HDMI OUT Connector| Connect to an HDMI acceptor to embed an audio signal
from the matrix.
10| HDMI IN Connector| Connect to an HDMI source to de-embed the audio signal
(the video signal is passed through to the output).
11| S/PDIF OUT RCA Connector| Connect to a digital stereo audio acceptor.
12| S/PDIF IN RCA Connector| Connect to a digital stereo audio source.
13| SPEAKER OUT| Outputs two selected audio signals in two channels.
•For Lo-Z: connect stereo output to Lo-Z speakers: L+ and L- to the left
speaker; R+R- to the right speaker.
•For Hi-Z (70V or 100V): connect Hi-Z and COM to mono Hi-Z speakers.
14| Dante PoE RJ-45 Port| Connect to Dante audio through the network. Provides
4 Tx channels and 4 Rx channels. By default, DHCP is enabled.
15| RS-232 3-pin Terminal Block Connector| Connect to a PC/serial controller
to control the device.
16| ETHERNET RJ-45 Connector| Connect to a PC via a LAN to control the device
and for firmware upgrades.
17| Micro USB PROG. PORT| Connect to your PC to control the device.
18| RESET Recessed Button| Press and hold for 5 seconds, to reset the
configuration to its default parameters.
19| Mains Power Connector and Fuse| Plug in for the power cord.
20| POWER Illuminated Power Switch| Turns the device on and off.
Step 3: Mount AFM-20DSP-AEC
To rack mount the machine, attach both rack ears (remove the screws from each side of the machine and replace screws through the rack ears) or place the machine on a table.
- Ensure that the environment (e.g., maximum ambient temperature & airflow) is compatible for the device.
- Avoid uneven mechanical loading.
- Appropriate consideration of equipment nameplate ratings should be used for avoiding the overloading of the circuits.
- Reliable earthing of rack-mounted equipment should be maintained.
Step 4: Connect inputs and outputs
Always turn off the power on each device before it is connected to the AFM- 20DSP-AEC device.
For optimum range and performance, use the recommended Kramer cables available
at
www.kramerav.com/product/AFM-20DSP-AEC. The use of third-party cables may cause damage!
Step 5: Connect the power
Connect the power cord to AFM-20DSP-AEC and plug it into the mains
electricity.
Safety Instructions (See www.kramerav.com for updated safety information)
Caution:
- There are no operator serviceable parts inside the unit.
Warning:
- Use only the power cord that is supplied with the unit.
- Disconnect the power and unplug the unit from the wall before installing.
- Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only.
- To ensure continuous risk protection, replace fuses only according to the rating specified on the product label is located on the bottom of the unit.
Step 6: Operate AFM-20DSP-AEC
To operate AFM-20DSP-AEC, use:
- Embedded web pages via the Ethernet.
- RS-232 serial commands are transmitted by a touch screen system, PC, or another serial controller.
Baud Rate: | 115,200 | Parity: | None |
---|---|---|---|
Data Bits: | 8 | Command Format: | ASCII |
Stop Bits: | 1 |
Example: (adjust the amplified audio from analog audio 1 to -10dB): #x-aud-lvl
out.amplified_audio.1.audio.1,-10
Default Ethernet Parameters
IP Address:| 192.168.1.39| UDP Port #:| 50000
Subnet mask:| 255.255.0.0| TCP Port #:| 5000
Gateway:| 192.168.0.1| Username/Password| Admin/Admin
Factory Reset
Recessed Button| default parameters.|
Protocol 3000:| “#factory” command.
Web Pages:| In the Settings page, click Factory Reset.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>