Avem Quirks Upright Glass Door Cooler - Logo OPERATING AND INSTRUCTION MANUAL
Upright Glass Door Cooler
CLIMATIC CATEGORYAvem Quirks Upright Glass Door
Cooler

SAFETY PRECAUTIONS

  • The purpose of the safety precautions in this manual is to ensure the safe and correct use of the unit to minimize risks that could cause serious damage and injury to you or other persons. The safety precautions are divided into WARNINGS and CAUTIONS. Cases, where improper handling of the unit could lead to death or serious injury, are listed under the ” **WARNING” heading. However, the cases listed under the ” ****CAUTION” heading could also lead to serious results. To ensure safety, adhere strictly to both types of safety precautions.
    WARNING Improper handling of the unit could lead to death or serious injury.
    CAUTION** Improper handing of the unit could lead to serious results depending on the circumstances.

  • Text set off by the exclamation mark contains information that should be strictly adhered to.

  • After reading the instruction manual, store it an easily accessible place where the user(s) of this product can easily find it.

PRECAUTIONS FOR INSTALLATION

WARNING
Installation should be performed only by the dealer or a qualified expert. Attempting to install the unit yourself could result in water leakage, refrigerant leakage, electrical shock, or fire.

PRECAUTIONS FOR INSTALLATION

WARNING

Installation should be performed only by the dealer or a qualified expert.
Attempting to install the unit yourself could result in water leakage, refrigerant leakage, electrical shock, or fire.| Never splash water directly onto the product or wash with water as a short circuit and electrical leakage could result.
---|---
Never put flammable or volatile substances into the unit as an explosion and fire could result.| Do not damage, modify, excessively bend, strain, twist or bundle up the power cord.
Also, placing heavy objects on the power cord or squeezing it in a tight place could damage it, possibly resulting in electrical shock or fire.
Use a dedicated wall outlet. Do not use extension cords or convenience receptacles as this could result in electrical shock, overheating, and a fire| Never use flammable spray cans or leave flammable substances near the unit.
Sparks from electrical switches could result in explosion and fire
The cooler is intended for storage and display of beer and beverages for sale. Do not use for another purpose than the intended as this could adversely affect items placed in the unit.| Never attempt to insert fingers, sticks, etc. fan is rotating at high speed inside the
outlet. Injury, electrical shock, and improper operation could result.
For indoor use only. Using the unit in a location exposed to rain could result in electrical leakage and electrical shock.| Never place heavy objects or items containing water on top of the unit. Objects could fall down and cause injury and spilled water could deteriorate the insulation of electrical components and result in electrical leakage.
Install the unit in a location where the floor is sturdy enough to support the load of the unit. If the floor is not sturdy enough or installation is incorrectly performed, the unit could tip over and falling shelves and products could cause personal injury.| If you find gas leakage, please don’t touch the cooler and close gas, and open the door for ventilation. Gas leakage causes explosion, fire, and fire injury.
Store the unit in a location where it is not exposed to rain. Using a unit that has been exposed to rain could result in electrical leakage and electrical shock.| Away from hot air sources. Cooling performance is reduced if the unit is placed
near heat sources such as hot plates and stoves and if it is exposed to direct sunlight.
Leave disassembly and disposal of the unit to qualified experts.| Should the unit need temporary storage, make sure not to store the unit in a location where children play and take precautions so that the door cannot be completely closed. This will minimize the risk that a child becomes trapped inside the compartment.
WELL VENTILATED PLACE
Please make more than 10cm space between cooler and wall. If there is no space, the cooling capacity can drop.| If installation in a damp location is unavoidable, also install an electrical leakage circuit breaker. If no electrical leakage circuit breaker is installed, an electrical shock could result.
Never hang from the door or climb onto the
unit. The unit could tip over or fall and
cause material damage or injury.| Disconnect the power cord plug from the wall outlet before moving the unit and make sure that the power cord is not damaged during transport. A damaged power cord could result in electrical shock and/or fire
Grasp the handle when closing the door. Holding at other positions could result in pinched fingers and injury.| Do not push your hand against or apply excessive force to glass surfaces as the glass could break and cause injury.
When disconnecting the power cord plug from the wall outlet, hold the plug main body close to the outlet. Pulling the cord could cause wire breakage, possibly resulting in overheating and fire.| Make sure that the unit does not tip over or fall when it is moved. A falling unit could cause serious injury.
Make sure that the unit does not tip over or fall when it is moved. A falling unit could cause serious injury.| Make sure that the unit does not tip over or fall when it is moved. A falling unit could cause serious injury.

HOW TO USE

BEFORE USE

  • Remove shipping package, tape, etc, and leave doors open ventilation for a while.
  • The unit is cleaned before shipment. However, clean the compartment interior once after delivery
  • Please insert a power supply plug into the wall outlet, single-phase to cat voltage.
  • Allow the unit to operate for about 1 hour to cool the compartment before placing items in the cooler

WAIT 5 MINUTES OR MORE BEFORE RE-STARTING

  • Restarting the unit immediately after it has been turned off may cause fuses to blow and activate the circuit-breaker, the compressor may be overloaded, and/or other damage may occur

TEMPERATURE ADJUSTMENT

  • For showcase cooler, the interior temp. during fully loaded at the factory default setting of position at 4-5 will be kept at 0-10℃. If the ambient temp. is extremely high or the stuffing food inside is too much, which might cause the interior temp. a little bit higher. So, it would be better to turn the thermostat right so as to maintain the right temp. On the opposite, if the ambient temp. is very low or empty loaded, or in less food storage, the interior temp. might be able to reach minus 0℃, and in return cause the evaporator to ice up; Thus, it would be better to switch the thermostat back to the left so as to relieve something.

DRAIN TRAY

  • Defrosting is performed automatically and drain water is collected in the drain tray.
  • Water in the drain tray is evaporated automatically. In humidity, a large amount of water in the drain tray, so please throw away drain the water once a day.

EFFICIENT USE
Please follow the below instruction, you could save energy.

  • To prevent cold air from escaping, open and close the door quickly and keep the door opened for as short a time as possible.
  • Please install the unit in a place that is well-ventilated.

SHELF HEIGHT ADJUSTMENT
The shelf height can be adjusted

  • Arrange the shelves in accordance with the dimensions of the items to be placed in the cooler.

Shelf Overload:The Model ME-LD60A:23kg,ME-LD65A:26kg,ME-LD70D:35kg,ME- LS111AHA:27kg, ME-LS133AHA:35kg,ME-LT180AHA:31kg.Avem Quirks Upright Glass
Door Cooler - Image 2

PLACING ITEMS IN THE SHOWCASE

This showcase employs a forced circulation of the cold air system. If the circulation of cold air is obstructed, the items will not be adequately refrigerated. Pay attention to the following points:

  • Do not let items obstruct the cold air inlet and suction outlet.
  • Place items so that they do not protrude from the shelves. The gap between the shelves and the door is used for the circulation of cold air.
  • Place items evenly on all shelves.
  • Please do not display goods on the bottom. Please put goods on the shelf.

CLEANING

WARNING
To prevent any electrical shock hazards or injury by rotating the circulation fan, always disconnect the power cord plug from the wall outlet before cleaning.
EXTERIOR AND COOLER COMPARTMENT

  • Wipe with a soft, dry cloth. If very soiled, wipe with a cloth that has been moistened with a detergent. Then wipe with a cloth that has been dipped in water.

WARNING
WARNING: Do not splash water directly onto the cooler and do not wash with water. Short-circuit and electrical shock could result.

  • Clean the cooler regularly to keep it clean at times.
  • Never use polishing powder, soap powder, benzene, Oil, or hot water as these will damage the painting and Plastic components Avem Quirks Upright Glass Door Cooler - Image 1

CHECKS
To ensure safety, perform the following checks after cleaning.

  • Is the power cord plug firmly inserted into a dedicated wall outlet? Confirm that the plug is not abnormally hot.
  • Check the power cord for cracks and damage. Should the slightest irregularity be observed, contact the dealer from whom you purchased this unit or our customer’s service.

In case the unit shows operating problems, check the following prior to calling the authorized service company:

SYMPTOMS POSSIBLE CAUSE SOLUTION
The unit is not operating Faulty electrical contact Verify electrical

connections
Poor electrical power| Check the power connection and electrical outlet
Thermostat setting “0”| Change the thermostat setting to a higher number
Not reaching the desired temperature| Unit is exposed to direct sunlight| Relocate the unit to a shaded area
The thermostat is not properly adjusted| Adjust the thermostat setting to a higher number
Clogger condenser| Review Maintenance instructions listed in the manual
Blocked grills| Clean the grills of any debris collected
The door was not properly closed| Check the leveling of the unit and door seal
Products poorly distributed or excess product load| Redistribute the product load according to Start instructions
For Models with electronic temperature controller indicates EO or El| Unplug the unit from the outlet. if the error continues, contact an authorized service technician
Abnormal noises| The unit is not properly leveled| Level the unit following the Installation instruction
Friction with other objects| Move the unit and avoid contact with other objects
Water on the floor| The drain hose is outside of the drain pan| Locate the hose in the drain pan

WARRANTY & SERVICE

  • The warranty is valid for one year from the date of purchase.

  • The warranty covers defective parts and workmanship.The following items are not covered under warranty:
    1. Loss of products.
    2. Damages caused by transportation.
    3. Damages caused by modifications made by
    unauthorized individuals.
    4. Fluorescent lights, glass parts, or plastic component parts.
    5. Worn out plugs or defective electrical components.
    6. Maintenance of the unit.

  • The warranty is valid showing the purchase receipt.

  • We offer a professional service network that offers the necessary technical support for your unit.

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid hazards.

  • Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.

  • See contact information in the back of the Manual.

  • WARNING-Be cautious not to cause fire when maintaining the Cooler as the Cooler and vesicant is burnable. Useless and old Cooler should be recycled and disposed of by professional companies.

Avem Quirks Upright Glass Door Cooler - Image 0