ECOLAB Professional Satellite SM and SM-PD Series Installation Guide
- June 5, 2024
- ECOLAB
Table of Contents
ECOLAB Professional Satellite SM and SM-PD Series
General information
For safety reasons, it is important to read all of the enclosed information
( Installation guide, Service manual, Spare parts, Operating instructions)
before mounting this equipment.. In addition, the legislation in force at the
time of purchase must always be considered in connection with the installation
and mounting of this equipment, no matter the contents of this manual. If
there are matters of a dispute please contact your dealer.
This equipment is produced and tested by specially qualified personnel,
following approved instructions to ensure our high level of product quality.
After the product is finished and tested it is manually inspected with the
ultimate test carried out just before the product is released for shipping. To
obtain our high level of quality and long life we use stainless steel parts.
These parts, in defiance of our manual inspections, may still have some sharp
edges, which can present a cut hazard. Therefore it is advised always to use
protective gloves and show caution when installing the equipment.
Preparation
If the wall is made of bricks or concrete, the enclosed screws and rawl plugs
are usable otherwise you have to make sure that the carrying capacity of the
wall is sufficient.
Note: The pipeline must be rinsed through before the system is connected.
See service manual
Note: Remove cover before the system is mounted on the wall.
Note: The weight of the unit is listed in the Service manual under the
section “Specifications”
Placing/application
- Do not use the machine outdoors.
- The satellite must be placed in frost-free rooms only.
- Free space around the satellite: min 1000 mm.
Water supply
SM3 | SM-PD | |
---|---|---|
Water volume | 30 l/min. | 6 l/min. |
Pressure | 1,2 – 2,5 MPa |
(12 – 25 bar)
| 0,5 – 1,0 MPa
(5 – 10 bar)
Max. temperature| 70oC| 70oC
The supply line must be sized so that it can supply the minimum indicated
pressure and water volume when connected to this equipment. When dimensioning
the water supply, It is recommended to increase the available volume
with 15-20 % compared to the minimum requirements listed in the table.
Note: Recommended water hardness is 14 – 18 dH°. The equipment will operate
with water hardness exciding this level however, descaling of pump system,
injectors, and like must be expected depending on use pattern and water
quality. Furthermore, the wear of the mechanical parts will increase as well.
If not
supplied, the filter should be mounted.
Air supply
The air supply for the system is to meet the following specifications:
- Pressure 6 – 10 bar
- Consumption 200 Nl/min.
Piping
The pipe system should be made of stainless steel pipes. The pipe joints
should be made in a way that makes separation possible in case of e.g.
repairs, movement, or similar.
Pipe connections | SM3 | SM-PD |
---|---|---|
Water | 3/4″ RG | 1/4″ RG |
Air | 6 mm | 6 mm |
Note: A 1/2” closing valve should be mounted on the water supply
immediately before the satellite and dirt filter if any.
A 1/4” closing valve should be mounted on the PD supply immediately before the
satellite and dirt filter if any.
Assembly
Dimensions see fig.1
It is recommended to mount the system at an appropriate height (approx. 1, 25
m above the floor) on a brick or concrete wall. Tighten the satellite with the
enclosed screws and rawl plugs.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>