Lupo Super Panel Dual Color 60 Hard Soft User Manual

June 5, 2024
Lupo

Panel Dual Color 60 Hard Soft
User Manual
Release 4. xx

SAFETY PRECAUTIONS:
Do not operate the equipment before studying the instruction manual and the accompanying safety precautions. Make sure that Lupo Safety Instruction is always included with
the equipment! Lupo products are intended for professional use. Do not place or use the equipment where it can be exposed to moisture, extreme electromagnetic fields, or in areas with flammable gases or dust! Do not expose the equipment to hasty temperature changes in humid conditions which could lead to condensation water in the unit. Equipment must only be serviced, modified, or repaired by authorized. Dealers or the factory.
CAUTION – BURN HAZARD – HOT PARTS
Do not touch hot parts with bare fingers! LED bulbs and certain metal parts emit strong heat when used!
Do not point lamps too close to persons. Always use the fixtures with the front part closed.
NOTICE – EQUIPMENT OVERHEATING RISK
Do not obstruct ventilation by placing filters, diffusing materials, etc. over inlets and outlets of the equipment ventilation or directly over glass cover or LED bulbs.
FINAL DISPOSAL
Equipment contains electrical and electronic components that could be harmful to the environment.
Equipment may be returned to Lupo distributors free of charge for recycling according to WEEE. Follow local legal requirements for separate disposal of waste, for instance, the WEEE directive for electrical and electronic equipment on the European market, when product life has ended.
MAINTENANCE AND CARE
Please do not forget that the safe operation of lamp heads also includes their maintenance and care.
A visual inspection should be conducted before every use and an inspection of electrical safety should be conducted at least once every 12 months.
WARRANTY
The warranty period for Lupo products and those marketed by Lupo is twelve months from the date of delivery. Lupo guarantees that the goods it supplies are well manufactured and of good quality. The warranty guarantees the repair of any parts that show acknowledged defects in materials, construction, or workmanship during the warranty period. The guarantee excludes any liability for direct or indirect damage of any kind and for any reason, for which Lupo will therefore not be required to pay compensation. The customers shall see to deliver the parts that need repair or replacement to Lupo’s works at their own expense and risk. The repaired or replacement parts shall be delivered by Lupo ex-works. The customers will be charged for materials and labor or replacement of the product after the expiration of the warranty period.
WARNING:
When hanging the fixture from a higher position, please make sure you use a safety cable to attach the barn doors to the yoke of the panel. Barndoors should always be used to secure the fixture and the application when used in this way.
Another safety cable should be used to secure the fixture to the mounting pipe or truss. Both safety cables must be properly dimensioned for the fixture and the application when the fixture is operated in a hanging position please ensure that the accessories are installed correctly with the top latch locked.
Thanks for having purchased Lupo products. All the products are made in Italy and all the efforts have been put to keep the quality standards high. We hope this product can help you in your job and make your life easier as a professional. We also hope you will enjoy its use and we would be happy to receive your feedback about it.

Instructions

  • Device for indoor use only.
  • Maximum ambient temperature: 40 °C.
  • Make sure the power supply plug is suitable for the power required.
  • As prescribed by international regulations, a safety cable must be used when the fixture is suspended from the ceiling.
  • To switch on the light push the on/off button.
  • Superpanel models are equipped with new-generation high-quality power.

Getting Started

Turning on the Superpanel

  1. Place the AC Adapters in the mounting brackets via the 2 captive screws of the SUPERPANEL 60 fixture.Lupo Super Panel Dual Color 60 Hard Sof - Superpanel
  2. Insert the power cord cables into the AC adapters and connect the fixture to the power plug.Lupo Super Panel Dual Color 60 Hard Sof - Superpanel 1
  3. Insert the DC XLR 4 pin connectors into the input jacks on the SUPERPANEL 60 and power on the fixture.

Functioning

Lupo Super Panel Dual Color 60 Hard Sof - Functioning

CONTROL PANEL
  • In current mode press the 5 push button to enter the main MENU.
  • In the sub-menus press the 5 push button to confirm a selection.
  • Rotate the 5 knobs to navigate the main MENU and sub-menus.
  • Use the « INTENSITY » 4 knobs to adjust the light intensity from 0 to 100%.
  • Use the knobs 5 and 4 to adjust the light mode parameters.
  • Display 3.

ATTENTION: The light intensity level is adjustable from 0 – 50% if the FAN is OFF. The value on the display flashes.

MANUAL OPERATION
  1. Press the 5 push button to enter the main MENU.
  2. Select MANUAL by pressing the 5 push button.
  3. Select the light mode between CCT   / EFFECT with the 5 knobs and press the 5 push button to confirm the selection.
  4.  See LIGHT MODES.
DMX OPERATION
  1. Press the 5 push button to enter the main MENU.
  2. Select DMX with the 5 knobs and press the 5 push button to confirm the selection.
  3. Select the light mode between CCT / EFFECT with the 5 knobs and press the 5 push button to confirm the selection.
  4. Select the DMX channel, rotating the 5 knobs to change DMX ADDRESS in ascending or descending order between 1 and 512. The number shown on the display 3 is the selected channel to communicate with the control desk.
  5. See DMX PROTOCOL MANUAL to DMX channel specification.

NOTE: The symbol – ! – on the display indicates that there is no DMX signal.

BLUETOOTH

Enable / Disable BLE App interface

DMX OPERATION – Advanced Settings
  1. Press the 5 push button to enter the main MENU.
  2. Navigate through the main MENU with the 5 knobs and press the 5 push button to confirm the selection.
  3. Rotate the 5 knobs to select DMX ADVANCED , and press the 5 push button to confirm the selection.
  4. Select one of the options among the DMX BIT, DMX SIGNAL LOSS , and RDM ENABLE, press the 5 push button to confirm the selection.

DMX BIT:
Resolution of the DMX control. 8bit 1 channel per function and 16 bit 2 channels per function.

  1. Select the DMX BIT item by pressing the 5 push button.
  2. Rotate the 5 knobs to choose between 8bit / 16bit, and press the 5 push button to confirm the selected setting. See DMX PROTOCOL MANUAL.

DMX SIGNAL LOSS:
This feature allows choosing the device’s behavior in case of a DMX signal loss.

  1. Select the LOSS DMX SIGNAL item with the 5 push button
  2. Rotate the 5 knobs to select the device’s behavior between BLACKOUT /SETTINGS
    LAST / SETTINGS 1min, press the 5 push button to confirm the setting.

Blackout: The device switches off.
Settings Last: The values of the last selected setting are maintained over time until the device is switched off.
Settings 1min: The values of the last selected settings are maintained for one minute and then the device is switched off.
RDM Enabled: ON/OFF, enable/disable RDM Protocol

LIGHT MODES

MODE| INTENSITY 4| CCT/HUE 5| GN/SAT/COLOR 6| « » 1 « » 3
---|---|---|---|---
CCT| Light Intensity
from 0 to 100%| CT 2800K to 10000K| GN -1.00 to +1.00| –
EFFECT| “See EFFECT table”| “See EFFECT table”| Change Effect

In CCT Mode, the « » 1 key selects the STROBE page, and the « » 2 key exits the STROBE PAGE.
In the STROBE PAGE, it is possible to set the DIMMER value and the STROBE frequency by rotating the 5 buttons.
ATTENTION: STROBE frequency = 0 means STROBE effect OFF.
A. CCT MODE: Warm and cold white control mode. It allows you to adjust color temperature (CCT), green/magenta compensation (GN), and light intensity. This is the default setting.
B. SPECIAL EFFECT MODE: Mode with 3 SPECIAL EFFECTS. TELEVISION BW / PAPARAZZI / LIGHTNING

  1. In the MANUAL OPTIONS or DMX MODE menu select EFFECT MODE.
  2. Select the EFFECT to be activated with rotate the 5 buttons, and confirm the selection by pressing the 5 push button.
  3. In current mode, use the « » 1 o « » 2 buttons to change the EFFECT in ascending or descending order. THE EFFECT ON THE DISPLAY IS THE SELECTED EFFECT.
  4. Use the knobs 5 and 4 to adjust the effect setting values. See table below.

EFFECT| 4 INTENSITY knob| 5 CCT/HUE knob| 6 GN/SAT/COLOR knob
---|---|---|---
TELEVISION BW| Light Intensity
from 0 to 100%| White range – 1 / 2 / 3 / 4| Frequency – 4 to 24 Hz
PAPARAZZI| Flashing Interval – 1 to 10| Bulb type – 0 / 1 / 2
LIGHTNING| Color Temperature| Lightnings Interval – 1 to 20

DEVICE SETTINGS
  1. Press the 5 push button to enter the main MENU.
  2. Navigate through the MENU rotating the 5 buttons, selecting DEVICE SETTINGS, and press the 5 push button to confirm the selection.
  3. Navigate through the FAN / DISPLAY / MENU VIEW / FILTER / LINEARIZATION / CCT LIMIT functions, rotating the 5 buttons to select the desired function and pressing the 5 push button to confirm the selection.
  4. Within each function select the option to be activated and rotate the 5 buttons.

Fan: Fan operation. ON / OFF.
When the fan is of the light intensity be adjustable between 0 and 50%.
Display: Time during which the display backlight stays on. 30sec / 1min / ALWAYS ON.
Menu View: Type the main MENU, sub-menus, and functions to show. ONLY MANUAL / ONLY DMX / MANUAL/DMX.
Filter: It is the speed response of the system (smooth factor).
FULL SPEED / NORMAL SPEED / HIGH SPEED / LOW SPEED.
Linearization: Linearization is the compensation curve for the human eye’s perception of the luminous intensity emitted as a function of the required power. Required power = dimmer value on the display. LINEAR / EXPONENTIAL / LOGARITHMIC.
Linear: No compensation, the intensity of the light is directly proportional to the requested power.
Exponential: The light intensity increases from 0 to 100 exponentially.
Logarithmic: The light intensity increases from 0 to 100 logarithmically.
CCT Limit: The color temperature is limited. 3200K – 5600K / 2800K – 10000K.

RESET DEVICE
  1. Press the « OK » 2 buttons to enter the main MENU.
  2. Select RESET DEVICE to rotate the 5 buttons, and press the 5 push button to confirm the selection.
  3. Select YES to rotate the 5 buttons, and press the 5 push button to confirm the selection.
  4. The device asks for further confirmation, select YES by pressing the press the 5 push button. THE DEVICE RETURN TO FACTORY DEFAULT SETTINGS.

FACTORY DEFAULT SETTING

MANUAL OPERATION
MODE: CCT| DEVICE SETTINGS
FAN: ON
DISPLAY: 1 min
MENU VIEW: Manual/DMX
FILTER: Normal speed
LINEARIZATION: Linear
CCT LIMIT: 2800K – 10000K
DMX OPERATION
MODE: CCT
BIT: 8 BIT
DMX SIGNAL LOSS: Settings 1 MIN
RDM ENABLE: OFF| BLUETOOTH
Bluetooth Active: OFF

Package Contents

Superpanel 60Lupo Super Panel Dual Color 60 Hard Sof - Superpanel
60

AC Power Cord with AC Power Cord Splitter|
---|---
2x AC Adapter Mounting Bracket|
2x AC Adapter
AC input: 100 V – 240 V
DC output: 24 V|

**ATTENTION:** Please keep the original package of the product in a safe place for warranty reasons.

DMX OPERATION – DMX protocol

The Actionpanel can be used with 8 bits (1 channel per function) and 16 bits (2 channels per function). The Actionpanel uses consecutive channels starting from the DMX address set on the panel used as a reference for the connection to the control desk. Please take the above into consideration when using many units of Actionpanel to avoid overlaps.

DMX Channel Protocol – 8 bit

MODE| CHANNELS USED| DMX CHANNEL POSITION
CCT or MONOCOLOR| 3| 1. DIMMER
2. COLOR TEMPERATURE
3. STROBE
TELEVISION
| 3| 1. DIMMER
2. WHITE RANGE
3. FREQUENCY
PAPARAZZI| 3| 1.DIMMER
2.INTERVAL
3.BULB TYPE
LIGHTNING
| 3| 1. DIMMER
2. COLOR TEMPERATURE
3. INTERVAL
DMX Channel Protocol – 16 bit
MODE| CHANNELS USED| DMX CHANNEL POSITION
CCT or MONOCOLOR| 6| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. COLOR TEMPERATURE – byte 1
4. COLOR TEMPERATURE – byte 2

5. STROBE – byte 1
6. STROBE – byte 2

TELEVISION| 6| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. WHITE RANGE – byte 1
4. WHITE RANGE – byte 2
5. FREQUENCY – byte 1
6. FREQUENCY – byte 2
PAPARAZZI
| 6| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. INTERVAL – byte 1
4. INTERVAL – byte 2
5. BULB TYPE – byte 1
6. BULB TYPE – byte 2
LIGHTNING*| 6| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. COLOR TEMPERATURE – byte 1
4. COLOR TEMPERATURE – byte 2
5. INTERVAL – byte 1
6. INTERVAL – byte 2

*Channel in use only the Dual Color version.

Update the Firmware

  1. Copy the file on a USB Pendrive (FAT32 formatted) in the main root;
  2. Switch off the equipment and insert the USB Pendrive;
  3. Switch on the equipment;
  4. Wait until the display backlight flashes (it takes several minutes and the red led must toggle for all-time long);
  5. Switch off the equipment;
  6. Extract the Pendrive and switch on the equipment: the firmware is updated.
  • Select “EXIT” to return to the current model.
  • Select “BACK” to return to the previous menu.
  • After 1 minute of inactivity in the menu, the device automatically exits and returns to the last selected mode.

Lupo Super Panel Dual Color 60 Hard Sof - submenus

RDM Protocol Specification

COMMAND PID DESCRIPTION
Manufacturer ID 0x0622 Manufacturer identification number

(LUPO Lighting).
Device Identification
Model ID| | Model identification number
| Ox0000| Dayle 650 mono color
| Ox0001| Dayle 650 dual-color
| 0x0002| Dayle 1000 mono color
| 0x0003| Dayle 1000 dual-color
| 0x0004| Dayle 2000 mono color
| 0x0005| Dayle 2000 dual-color
| 0x0006| Superpanel 30 dual-color soft
| 0x0007| Superpanel 30 dual-color lens
| 0x0008| Superpanel 30 fullcolor soft
| 0x0009| Superpanel 30 fullcolor lens
| Ox0010| Superpanel 60 dual-color soft
| Ox0011| Superpanel 60 dual-color lens
| 0x0012| Superpanel 60 fullcolor soft
| Ox0013| Superpanel 60 fullcolor lens
| 0x0014| Actionpanel dual-color soft
| 0x0015| Actionpanel dual-color lens
| 0x0016| Actionpanel full-color soft
| 0x0017| Actionpanel full-color lens
| 0x0018| Kickasspanel dual color
| 0x0019| Kickasspanel fullcolor
| 0x0020| Leupold monocolor
| 0x0021| Lupoled dualcolor
Personality| | DMX Personality
| ox00| CCT
| Ox01| HSI
| 0x02| RGBW
| 0x03| FRGBW
| 0x 04| PRESET
| 0x05| PARTY
| 0x06| COPCAR
| 0x07| DISCO 1
| 0x08| DISCO 2
| 0x09| TELEVISION BW
| OxOA| TELEVISION CO
| OxOB| PAPARAZZI
| OxC| LIGHTNING
| OxOD| EXPLOSION
| OxOE| FIREWORKS
| OxOF| FIRE
Network management|
DISC UNIQUE BRANCH| Ox0001| Search RDM devices
DISC MUTE| 0x0002| Mute RDM device, no response message
DISC UN MUTE| 0x0003| Activate the RDM device for the response message
Status collection|
QUEUED MESSAGES| 0x0020| Retrieves queued messages or status messages if no message is in the queue
STATUS MESSAGES| 0x0030| Retrieves current Warning/Error messages
RDM Information|
SUPPORTED PARAMETERS| 0x0050| Retrieves a list of all supported RDM commands
PARAMETER DESCRIPTION| 0x0051| Retrieves a list of all RDM commands
Product Information|
DEVICE INFO| 0x0060| Retrieves a variety of information about the device that is normally required by a controller.
DEVICE MODEL DESCRIPTION| 0x0080| Text description of up to 32 characters for the device model type.
MANUFACTURER LABEL| 0x0081| This parameter provides an ASCII text response with the Manufacturer’s name for the device. “LUPO” is the default name.
FACTORY DEFAULTS| 0x0090| Set the device to its factory defaults. Get: Check if settings still in default state -> 1 if default
SOFTWARE VERSION LABEL| Ox00C0| Retrieves software version string of main software
DM X512 Setup|
DMX PERSONALITY| Ox00E0| DMX mode
DMX PERSONALITY DESCRIPTION| Ox00E1| Shows a description of a DMX-Mode, max 32 characters
DMX START ADDRESS| Ox00F0| DMX address
Control|
IDENTIFY DEVICE| Ox1000| The identify flag (flashes the light)
Manufacturer Commands|
FAN MODE| 0x8001| 0: Off 1: On
DISPLAY TIMEOUT| 0x8002| 0: 30 sec 1: 1 min 2: always on
DMX SIGNAL LOST MODE| Ox8003| 0: blackout 1: last settings on 2: last settings 1 min
DMX BITS| Ox8004| 0: 8 bit 1:16 bit
CCT LIMIT| 0x8005| 0: 2800-10000 1: 3200-5600
LINEARIZATION| 0x8006| 0: linear 1: exponential 2: logarithmic
FILTER| 0x8007| 0: full speed 1: normal speed 2: high speed 3: low speed

Lupo srl – Via V. Sassi 28/30 Collegno (TO) – 10093 – Italy
Phone:
+39 011 411 9919
e-mail:[email protected]
website: www. Lupo.it

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Lupo User Manuals

Related Manuals