Lupo Superpanel PRO 30 Dual Color Hard User Manual

June 2, 2024
Lupo

Lupo Superpanel PRO 30 Dual Color Hard

Lupo-Superpanel-PRO-30-Dual-Color-Hard-product

Product Information

Specifications

  • Product Name: SuperpanelPRO 30, UltrapanelPRO 30
  • Color Options: Full Color, Dual Color
  • Country of Origin: Italy

Frequently Asked Questions

  • Q: Where are Lupo products manufactured?
    • A: All Lupo products are made in Italy to maintain high-quality standards.
  • Q: How do I provide feedback about the product?
    • A: We welcome your feedback! Please reach out to our customer support team or visit our website to share your thoughts on the product.

SAFETY PRECAUTIONS

Do not operate the equipment before studying the instruction manual and the accompanying safety precautions. Make sure that Lupo Safety Instruction is always included with the equipment! Lupo products are intended for professional use. Do not place or use the equipment where it can be exposed to moisture, extreme electromagnetic fields or in areas with flammable gases or dust! Do not expose the equipment to dripping or splashing. Do not place any objects filled with liquids on or near the equipment. Do not expose the equipment to hasty temperature changes in humid conditions as this could lead to condensation water in the unit. Equipment must only be serviced, modified or repaired by authorized and competent service personnel!

CAUTION:  BURN HAZARD – HOT PARTS

Do not touch hot parts with bare fingers! LED bulbs and certain metal parts emit strong heat when used! Do not point lamps too close to persons. Always use the fixtures with the front part closed.

NOTICE:  EQUIPMENT OVERHEATING RISK

Do not obstruct ventilation by placing filters, diffusing materials, etc. over inlets and outlets of the equipment ventilation or directly over glass cover or LED bulbs.

FINAL DISPOSAL

When no longer in use, this product may not be deposited in normal household waste but should be brought to a collection point for the recycling of electrical and electronic appliances. The materials are recyclable as marked. By re-use, recycling or another form of using old appliances you are making an important contribution towards the protection of the environment. Please ask your local authorities for the appropriate disposal point. Equipment contains electrical and electronic components that could be harmful to the environment. Equipment may be returned to Lupo distributors free of charge for recycling according to WEEE.

Follow local legal requirements for separate disposal of waste, for instance WEEE directive for electrical and electronic equipment on the European market, when product life has ended!

MAINTENANCE AND WARRANTY

MAINTENANCE AND CARE

  • Please do not forget that the safe operation of lamp heads also includes their maintenance and care.
  • A visual inspection should be conducted before every use and an inspection of electrical safety should be conducted at least once every 12 months.

WARRANTY

Each Lupo product will be repaired free of charge by Lupo if during 12 months for mechanical components and 12 months for electrical/electronic components from the date of purchase its working order is impaired through a manufacturing or material defect. The faulty product should be immediately sent to authorized dealer or Lupo. This warranty is not valid for equipment that has been used improperly, dismantled, modified or repaired by persons not belonging to the Lupo distribution network. It does not cover lamps, lenses or the material entirely or partially made of glass. No responsibilities can be accepted for damage resulting from the unsatisfactory operation of the equipment.

Please contact the dealer who sold the fixture/s before any units are returned for repair. Lupo will make the final determination as to whether or not the unit is covered by warranty. Lupo will replace or repair to proper working condition any products that are returned under warranty. Products repaired or replaced under warranty are under warranty only for the remaining unexpired period of time of the original warranty. Any product unit or part returned to Lupo must be packaged properly to ensure the protection of such product unit or parts. The package must be clearly an prominently marked to indicate that the package contains returned product units or parts. All returned product units or parts must be accompanied by a written explanation of the alleged problem or malfunction.

WARNING:

When hanging the fixture from higher position, please make sure you use a safety cable to attach the barn doors to the yoke of the fresnel. Barndoors should always be secured to the yoke when used in this way.

Another safety cable should be used to secure the fixture to the mounting pipe or truss. Both safety cables must be properly dimensioned for the fixture and the application when the fixture is operated in hanging position please ensure that the accessories are installed correctly with top latch locked.

Thanks for having purchased Lupo products. All the products are made in Italy and all the efforts have been put to keep the quality standards high. We hope this product can help you in your job and make your life easier as a professional. We also hope you will enjoy its use and we would be happy to receive your feedback about it.

Instructions

  • Device for indoor use only.
  • Maximum ambient temperature: 40 °C.
  • Make sure power supply plug is suitable to power required.
  • As prescribed by international regulations, a safety cable must be used when the fixture is suspended from ceiling.
  • To switch on the light push the on/off button.
  • SuperpanelPRO and UltrapanelPRO models are equipped with new generation high quality powerleds.

Getting Started

Getting Started with the SuperpanelPRO 30 and the UltrapanelPRO 30

Lupo-Superpanel-PRO-30-Dual-Color-Hard-fig-1

Turning on the SuperpanelPRO 30 and the UltrapanelPRO 30

  1. Insert the POWERCON
  2. Rotate it by 15° until makes a click
  3. Turn ON the power switch:
    • 0: OFF
    • I: AC power
    • II: Battery power

CONTROL PANEL

  • In current mode press the 2 push button to enter the main MENU.
  • In the sub-menus press the 2 push button to confirm a selection.
  • Rotate the 2 knob to navigate in the main MENU and sub-menus.
  • Use the « INTENSITY » 2 knob to adjust the light intensity from 0 to 100%.
  • Use the knob 1 to adjust the light mode parameters.
  • Display 3 .

ATTENTION

  • The light intensity level is adjustable from 0 – 50% if the FAN is OFF. The value on the display flashes.

MODE

  1. Press the 2 push button to enter the main MENU.
  2. Select MODE by pressing the 2 push button.
  3. Select the light mode among CCT with the 2 knob and press the 2 push button to confirm selection.
  4. Select among CCT / PRESET / SAVE PRESET with the 2 knob and press the 2 push button to confirm selection
  5. See LIGHT MODES.

LIGHT MODES

Lupo-Superpanel-PRO-30-Dual-Color-Hard-fig-5

CCT MODE

  • Warm and cold white control mode. It allows you to adjust colour temperature (CCT), and light intensity. This is the default setting.

ATTENTION: Rotating the 1 knob changes the CT value- Pressing 1 button select GN value that can be changed by rotating the same 1 knob.

DMX OPERATIONS

  1. Press the 2 push button to enter the main MENU.
  2. Select CONTROL with the 2 knob and press the 2 push button to confirm selection.
  3. Select DMX with the 2 knob and press the 2 push button to confirm selection.
  4. Select the DMX channel, rotating the 1 knob to change DMX ADDRESS in ascending or descending order among 1 and 512. The number shown on the display 3 is the selected channel to communicate with the control desk.
  5. See DMX PROTOCOL MANUAL for DMX channel specification.

NOTE

  • The symbol – ! – on the display indicates that there is no DMX signal.

BLUETOOTH

  1. Press the 2 push button to enter the main MENU.
  2. Select CONTROL with the 2 knob and press the 2 push button to confirm selection.
  3. Select BLE with the 2 knob and press the 2 push button to confirm selection.

DMX OPERATIONS – Advanced Settings

  1. Press the 2 push button to enter the main MENU.
  2. Navigate through the main MENU with the 2 knob until DEVICE SETTINGS and press the 2 push button to confirm selection.
  3. Rotate the 2 knob to select DMX ADVANCED, press the 2 push button to confirm selection.
  4. Select one of the options among the DMX BIT, DMX SIGNAL LOSS, RDM ENABLE, STROBE ENABLE and INV CCT press 2 push button to confirm the selection.

DMX BIT:

Resolution of the DMX control. 8bit 1 channel per function and 16 bit 2 channels per function.

  1. Select the DMX BIT item by pressing the 2 push button.
  2. Rotate the 2 knob to choose between 8bit / 16bit, press the 2 push button to confirm the selected setting. See DMX PROTOCOL MANUAL.

DMX SIGNAL LOSS:

This feature allows to choose the device’s behaviour in case of a DMX signal loss.

  1. Select the LOSS DMX SIGNAL item with the 2 push button
  2. Rotate the 2 knob to select the device’s behaviour among BLACK OUT /SETTINGS LAST / SETTINGS 1min, press the 2 push button to confirm the setting.
  • Black out: The device switches off.
  • Settings Last: The values of the last selected setting are maintained over time until the device is switched off.
  • Settings 1min: The values of the last selected settings is maintained for one minute and then the device switch off.
  • RDM Enable: ON/OFF, enable/disable RDM Protocol
  • INV CCT: ON/FF: enable/disable reversal CCT console control

DMX Protocol

Introduction

The SuperpanelPRO and UltrapanelPRO can be used with 8 bit or 16 bit DMX control. (See DMX OPERATION – advanced settings in the user’s manual). When used in 8 bit mode the panels uses one channel for each function. DMX values for each channel are in the range of 0 to 255. When used in 16 bit mode the panels uses two channels for each function. The increased resolution offers a smooth dimming and a more accurate color adjustment. DMX values for the first channel (byte 1) are in the range of 256 to 65535 while for the second channel (byte 2) they are in the range of 0 to 255.

ATTENTION: The symbol – ! – on the display indicates that there is no DMX signal.

ATTENTION: * If the STROBE in the DMX ADVANCED SETTINGS is enabled, there are 1 more channel in 8 bit and 2 more channels in 16 bit:

DMX Channel Protocol – 8 bit

MODE| CHANNELS| DMX CHANNEL POSITION| DMX VALUE| VALUE
---|---|---|---|---


CCT

| ****

2/3*

| 1. DIMMER| 0 – 255| 0 – 100 %
2. COLOR TEMPERATURE| 0 – 255| 6500 – 2700
3. *STROBE CONTROL| 0 ÷ 5| Ø
6 ÷ 255| 1 ÷ 25 Hz

DMX Channel Protocol – 16 bit

MODE| CHANNELS| DMX CHANNEL POSITION| DMX VALUE| VALUE
---|---|---|---|---



CCT

| ****


4/6*

| 1. DIMMER – byte 1| 0 – 65535| 0 ÷ 100 %
2. DIMMER – byte 2
3. COLOR TEMPERATURE – byte 1| 0 – 65535| 6500 – 2700
4. COLOR TEMPERATURE – byte 2
5. STROBE CONTROL – byte 1| 0 ÷ 1300| Ø
6.
STROBE CONTROL – byte 2| 1301 ÷ 65535| 1 ÷ 25 Hz

RDM Protocol Specification

COMMAND PID DESCRIPTION

Manufacturer ID

| ****

0x0622

| Manufacturer identification number (LUPO Lighting).
Device Identification
Model ID| | Model identification number
| 1| Dayled 650 mono color
| 2| Dayled 650 dual color
| 3| Dayled 1000 mono color
| 4| Dayled 1000 dual color
| 5| Dayled 2000 mono color
| 6| Dayled 2000 dual color
| 7| Superpanel 30 dual color soft
| 8| Superpanel 30 dual color lens
| 9| Superpanel 30 full color soft
| 10| Superpanel 30 full color lens
| 11| Superpanel 60 dual color soft
| 12| Superpanel 60 dual color lens
| 13| Superpanel 60 full color soft
| 14| Superpanel 60 full color lens
| 15| Actionpanel dual color soft
| 16| Actionpanel dual color lens
| 17| Actionpanel full color soft
| 18| Actionpanel full color lens
| 19| Kickasspanel dual color
| 20| Kickasspanel full color
| 21| Lupoled monocolor
| 22| Lupoled dualcolor
| 23| Movielight monocolor
| 24| Movielight dual color
| 25| Ultrapanel 30 dual color soft
| 26| Ultrapanel 30 dual color lens
| 27| Ultrapanel 60 full color soft
| 28| Ultrapanel 60 full color lens
| 29| Ultrapanel 30 full color soft
| 30| Ultrapanel 30 full color lens
| 31| Ultrapanel 60 dual color soft
| 32| Ultrapanel 60 dual color lens
| 33| Dayled 650 PRO Full Color
| 34| Dayled 1000 PRO Full Color
| 35| Dayled 2000 PRO Full Color
Personality| | DMX Personality
---|---|---
| 0x01| CCT
Network management
DISC UNIQUE BRANCH| 0x0001| Search RDM devices
DISC MUTE| 0x0002| Mute RDM device, no response message
DISC UN MUTE| 0x0003| Activate RDM device fo response message
Status collection
QUEUED MESAGES| 0x0020| Retrieves queued messages or status message if no message is in queue
STATUS MESSAGES| 0x0030| Retrieves current Warning/Error messages
RDM Information
SUPPORTED PARAMETERS| 0x0050| Retrieves a list of all supported RDM commands
PARAMETER DESCRIPTION| 0x0051| Retrieves a list of all RDM commands
Product Information
DEVICE INFO| 0x0060| Retrieves a variety of information about the device that is normally required by a controller.
DEVICE MODEL DESCRIPTION|

0x0080

| Text description of up to 32 characters for the device model type.

MANUFACTURER LABEL

|

0x0081

| This parameter provides an ASCII text response with the Manufacturer name for the device. “LUPO” is the default name.

FACTORY DEFAULTS

|

0x0090

| Set the device to its factory defaults. Get: Check if settings still in default state -> 1 if default

SOFTWARE VERSION LABEL

|

0x00C0

|

Retrieves software version string of main software

DMX512 Setup
DMX PERSONALITY| 0x00E0| DMX mode
DMX PERSONALITY DESCRIPTION|

0x00E1

|

Shows a description of a DMX-Mode, max 32 characters

DMX START ADDRESS| 0x00F0| DMX address
Control
IDENTIFY DEVICE| 0x1000| The identify flag (flashes the light)
Manufacturer Commands
FAN MODE| 0x8001| 0: Off 1: On
DISPLAY TIMEOUT| 0x8002| 0: 30 sec 1: 1 min 2: always on
DMX SIGNAL LOST MODE| 0x8003| 0: black out 1: last settings on 2: last settings 1 min
DMX BITS| 0x8004| 0: 8 bit 1: 16 bit
CCT LIMIT| 0x8005| 0: 2800-10000 1: 3200-5600
LINEARIZATION| 0x8006| 0: linear 1: exponential 2: logarithmic
FILTER| 0x8007| 0: full speed 1: normal speed 2: high speed 3: low speed
FREQUENCY| 0x8008| 0: 18 KHz 1: 25 KHz
INV – CCT| 0x8009| 0: not inverted 1: inverted

DEVICE SETTINGS
  1. Press the 2 push button to enter the main MENU.
  2. Navigate through the MENU rotating the 2 button, select DEVICE SETTINGS, press the 2 push button to confirm the selection.
  3. Navigate through the MENU rotating the 2 button, select GENERAL, press the 2 push button to confirm the selection.
  4. Navigate through the FAN POWER / DISPLAY / FREQUENCY / FILTER / LINEARIZATION / CCT LIMIT functions, rotating the 2 button to select the desired function and press the 2 push button to confirm the selection.
  5. Within each function select the option to be activated and rotate the 2 button.
    • Fan Power: Fan operation ON / OFF.
    • When the fan is OFF the light intensity be adjustable between 0 and 50%.
    • Display: Time during which the display backlight stays on. 30sec / 1min / ALWAYS ON.
    • Frequency: Dimmer frequency 18 KHz – 25 KHz
    • Filter: It is the speed response of the system (smooth factor).
    • FULL SPEED / NORMAL SPEED / HIGH SPEED / LOW SPEED.
    • Linearization: Linearization is the compensation curve for the human eye’s perception of the luminous intensity emitted as a function of the required power. Required power = dimmer value on the display. LINEAR / EXPONENTIAL / LOGARITHMIC.
    • Linear: No compensation, the intensity of the light is directly proportional to requested power.
    • Exponential: The light intensity increases from 0 to 100 exponentially.
    • Logarithmic: The light intensity increases from 0 to 100 logarithmically.
    • CCT Limit: CCT range 2800 – 6500 or 3200 – 5600

RESET DEVICE

  1. Press the « OK » 2 button to enter the main MENU.
  2. Select RESET DEVICE rotating the 2 button, press the 2 push button to confirm the selection.
  3. Select YES rotating the 2 button, press the 2 push button to confirm the selection.
  4. The device ask for further confirmation, select YES by pressing the press the 2 push button.THE DEVICE RETURNS TO FACTORY DEFAULT SETTINGS.

FACTORY DEFAULT SETTING

MODE| DEVICE SETTINGS
CCT| FAN: ON
DMX OPERATION| DISPLAY: 1 min
BIT: 8 BIT| FILTER : Normal speed
DMX SIGNAL LOSS: Settings 1 MIN| LINEARIZATION: Linear
RDM ENABLE: OFF| FREQUENCY: 18 KHz
INV – CCT: OFF| CONTROL
| Manual

USB PORT

  • Use USB port for firmware updates.

Update the Firmware

  1. Copy the file on an USB Pendrive (FAT32 formatted) in the main root;
  2. Switch off the equipment and insert the USB Pendrive;
  3. Switch on the equipment;
  4. Wait until display backlight stop flashing (it takes several minutes and display backligh must toggle for all time long);
  5. Switch off the equipment;
  6. Extract the Pendrive and switch on the equipment: the firmware is updated.

Package Contents

Package Contents for SuperpanelPRO 30 and UltrapanelPRO 30

Lupo-Superpanel-PRO-30-Dual-Color-Hard-fig-4..

ATTENTION: Please keep the original package of the product in a safe place for warranty reasons.

  • Select “EXIT” to return to the current mode.
  • Select “BACK” to return to the previous menu.

Lupo-Superpanel-PRO-30-Dual-Color-Hard-fig-6

NOTE: After 1 minute of inactivity in the menu, the device automatically exits and returns to the last selected mode.

Contact

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Lupo User Manuals

Related Manuals