RIBITECH PRCEN012 ASH Cleaner Cenetop Instruction Manual

June 5, 2024
RIBITECH

RIBITECH - logo RIBITECH PRCEN012 ASH Cleaner
Cenetop

ASH CLEANER CENETOP
User and maintenance manual

Art. Nr. : PRCEN012
Made in Italy
Product by RIBIMEX ITALIA s.r.l.

**** WARNING:
Carefully read this instruction manual before operating this appliance.
Incorrect operation may cause injury and/or damages.
Please keep this manual for future reference.

Unpacking: Remove the product from its packaging. Check that product and accessories are not damaged.

The use of this product by children is forbidden.

Contents of packaging:

Congratulations on your excellent choice.
In addition to its quality and reliability, our CENETOP ash cleaner is built for easy and safe long-term use.
This appliance has been designed for the suction of cold ash only, and for such reason is not suitable for boilers or for fuel oil stoves nor can it be used for plaster powder or cement dust. This appliance is designed for domestic use only.

IMPORTANT – Safety warnings – Read carefully before use

– Do not leave the ash vacuum cleaner plugged in when not in use. Always stop the appliance with the ON/OFF switch before taking the plug out of the socket.
– Do not pull the lead. To unplug, grasp the plug, not the cable.
The use of an extension cable is not recommended.
– Do not pull or carry by cable or use cable as a handle.
– Do not use it to vacuum water or other liquids.
– Do not use to pick up flammable or combustible liquids, such as petrol, or use in areas where they or their vapors may be present.
– The cover of the motor compartment must only be cleaned with a dry cloth.
– Do not leave the ash vacuum cleaner outdoors, it must always be kept in a dry place and not where it could be affected by bad weather conditions.
– Do not handle any part of the plug or appliance with wet hands.
– Do not disassemble the appliance as incorrect reassembly may result in an electric shock or fire.
– Do not stretch the cable or place the cable under strain. Keep the cable away from heated surfaces. Do not close a door on the cable, or pull the cable around sharp edges or corners. Arrange the cable away from the traffic area and where it will not be stepped on or tripped over.
– Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
– Keep hair, loose clothing, fingers, and all parts of the body away from openings and moving parts, such as the brush bar. Do not point the hose, wand, or tools at your eyes or ears or put them in your mouth.
– Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce airflow.
– To avoid a tripping hazard wind the cable when not in use.
– Hold the plug when rewinding onto the cable reel. Do not allow the plug to whip when rewinding.
– Electric lead: if the electric lead is damaged, it must be replaced by the manufacturer, by the manufacturer’s customer service, or by qualified people.
– This device is not intended for use by people (including children) with limited physical, sensorial or mental capacities or by people lacking in experience or knowledge unless they are assisted or shown how to use the appliance by a person responsible for their safety.

HOW TO PREPARE AND USE THE ELECTRIC ASH VACUUM CLEANER

– Position the appliance on a flat surface.
– Remove the accessories from the drum and insert the 4 wheels into the plastic base.
– Make sure that the HEPA filter and the pre-filter have been inserted in their housings (as indicated in Fig. 1)
– Connect the steel pipe to its fitting. (fig. 2)
– Before starting to clean the stove, make sure that all the ash has stopped burning and is sufficiently cool. Never suck burning embers.
– Plug the electric lead into a socket, making sure the voltage is suitable for the characteristics of the appliance, and check the rating label on the appliance.
– Turn the appliance on using the luminous ON/OFF switch located on the cover of the motor.
– Vacuum the ash directly from the fireplace or from the stove using the steel pipe.
– Whenever suction power appears to be decreasing, the Cenetop ash cleaner is designed to permit the cleaning of its filter during use:

RIBITECH PRCEN012 ASH Cleaner Cenetop - fig3

– As shown in Figure A, the filter can be cleaned during use or by closing the metal suction mouth.
– During suction or with the metal suction mouth closed, press the cleaning button shown in Figure B repeatedly.
– At this point, the residual ash has been removed from the filter and the normal suction process can be continued (Fig. C).
– After use, switch off the appliance and unplug it from its power socket.
– After stove or fireplace cleaning operations have been finished, clean the machine and the suction filter.

CLEANING AND MAINTENANCE

-Before proceeding with any cleaning or maintenance operation, always unplug the appliance from the power socket.
– Clean the outside of the machine using a dry cloth.
– In order to ensure constantly satisfactory operation, the container and the filter must be cleaned with a certain regularity. The dissatisfactory operation may be caused by the presence of residue or dirt inside the filter or the hose. In this case, we recommend switching off the appliance, unplugging it from its power socket, and then proceeding to the cleaning of its parts.
– Never empty the drum into an easily flammable container, and always make sure that the ash has cooled completely before doing so.RIBITECH PRCEN012
ASH Cleaner Cenetop - fig4

– In order to give the filter a thorough cleaning, start by raising the cover (Fig. D).
Incline the motor housing (Fig. E), and lightly tap the pre-filter in order to make all ash residue fall inside the drum (Fig. F). Then remove the pre-filter and the filter from their housings while always keeping the motor housing slightly inclined, rotating it slightly.
– Wash the outside of the filter and the pre-filter with a delicate flow of running water at room temperature in order to avoid damage (Fig. G). Use a soft brush to remove the residue that does not fall by itself. Never use hot water in order to avoid deforming the filter.
Do not use detergents. Leave the filter to dry naturally before replacing it in its housing. Do not place it close to hot sources of heat. Do not place it in direct sunlight.
– It is advisable, in any case, to clean a max. of 2/3 Kg of ash during each cleaning operation. Operate the filter reset lever, before each cleaning cycle.
– When the stove or fireplace has been cleaned, the appliance and suction filter must then be cleaned.
The cleaning operations should be done outdoors.
– Once the filter has been cleaned, check whether it is suitable for further use. If it has been damaged or broken, replace it with an original Ribimex filter (Ref. HEPA Filter: PRCEN003/HEPA – Ref. Prefilter: PRCEN000/CF)
– To take out the filter, remove it forcefully.
– To insert the new filter, press on it as far as it will go.

PREFILTER SUPPLIED WITH THE EQUIPMENT:
– Follow the instructions as indicated in the leaflet inside the package.

BLOWING FUNCTION

– In order to use the blowing function, with the appliance switched off, insert the hose into the air outlet hole (as shown in Fig. H). Then switch on the ash cleaner using the main power switch.

RIBITECH PRCEN012 ASH Cleaner Cenetop - fig5

BRUSH WITH NYLON BRISTLES
– In order to thoroughly clean stoves or fireplaces without scratching metal surfaces, use the brush with nylon bristles provided in the packaging.
The brush must be connected to the metal extension rod (as shown in Fig. I).

RIBITECH PRCEN012 ASH Cleaner Cenetop - fig6

TERMS OF WARRANTY

Our Cenetop ash cleaner has been subjected to strict inspection and is covered by a warranty against defects in fabrication in compliance with the regulations applicable in the various nations of use.
Warranty coverage begins from the date of purchase.
The following are not covered by warranty: parts subject to normal wear, rubber parts, filters, accessories and options, damage caused by accident, transport, neglectful or erroneous treatment, incorrect use, and installation.
Failure to respect the above automatically invalidates the warranty.
This appliance is exclusively designed for non-professional, domestic use. Warranty coverage will not be provided in the event of any other but private use.
Whenever breakage occurs or repair is required, always contact the Manufacturer’s Customer Assistance Service or Dealer.

| Do not dispose of this product with household rubbish. Dispose of this product in the nearest recycle center. Please contact your local authority or local recycle center for further information for its safe disposal.
---|---
****| Class II product with double insulation
| Wear eye protection.
| Wear protective gloves
| Keep children away: The use of this product by children is forbidden. Keep the product away from children or from their environment. Never allow children to operate the appliance. Children should be supervised to ensure that they do not play with the product. Never leave the product unattended.

DICHIARAZIONE DI CONFORMITA’ UE

EN 55014-1:2006 + A1:2009 + A2:2011
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 55014-2:1997 + A1:2001 + A2:2008
EN 62233:2008
EN 60335-1:2012 + AC:2014 + A11:2014
EN 60335-2-2:2010 +A11:2012 + A1:2013
EN 50581:2012

Luogo
Carrè (VI) Italy
Place

Data
26/09/2016
Date
Firma
Alessandro Guzzonato – Legale rappresentante
Signature
(nome e funzione)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

RIBITECH User Manuals