SUNCO LIGHTING SHG-40W-2PK 4FT LED Grow Light for Indoor Plants 40W Installation Guide
- June 5, 2024
- Sunco Lighting
Table of Contents
40W GROW LIGHT
Install Guide and Manual
COMPONENTS
EASY INSTALLATION
Suspension Install
-
Turn off a circuit breaker that provides power to the light switch.
-
Mounting surface must be able to support the weight of the fixture.
To install on plasterboard:
• Minimum 3/8 inch thickness required
• Minimum #8 eye hook screws with plastic anchors, or expansion bolts (not included) -
Drill pilot holes 46.75 inches apart. Insert two plastic anchors, then screw each eye hook into an anchor.
-
Depending on your lighting plan, space any additional anchors accordingly.
• Link up to 4 shop lights together -
Install a “V” hook into one end of the chain link provided. Loop one S Hook onto the other end of the chain.
• Repeat with the second chain. -
Use pliers to crimp ends and secure as needed.
-
Insert the “V” hook ends into the slots in the light fixture end cap. Repeat steps on the opposite side.
-
Hang the loose ends of the chain onto the Screw Eye hooks in the ceiling.
-
Plug the power cord into an electrical outlet.
Turn on the circuit breaker and test the light.
• Distance between lamp and plant surface should be between 12 – 39 inches.
WARNING
All electrical connections must be in accordance with local and National
Electric Code (N.E.C.) standards. Consult a qualified electrician if you are
unfamiliar with proper electrical wiring connections. Please review
instructions carefully before proceeding.
WARNING: Risk of fire or electric shock. Do not alter, relocate or remove
wiring during installation.
This fixture complies with Part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE: Not for use with dimmers. Do not install directly over a heat
source.
SPECIFICATIONS
Voltage | Damp |
---|---|
Wattage | Steel+PC |
Suitable for Locations Ingress | 2.70lbs |
Housing | 5 years |
Weight | 120V |
Warranty | 40W |
-
Turn off a circuit breaker that provides power to the light switch.
-
Mounting surface must be able to support the weight of the fixture.
• Plasterboard should be 3/8 inch thick. -
Install four plastic anchors 46.25 inches apart and 4.4 inches apart. Insert a screw into each anchor.
• Gap between cap nut and ceiling should be 0.33 inches. -
Depending on your lighting plan, space any additional anchors accordingly.
• Link up to 4 shop lights together -
Lift fixture up to screws and slide to one side to secure into place. The fixture should be firmly fixed against screws.
-
Distance from the lamp to the plant surface should be 12-39 inches.
-
Plug the power cord into an electrical outlet.
-
Turn on the circuit breaker and test the light.
WARNING
All electrical connections must be in accordance with local and National
Electric Code (N.E.C.) standards. Consult a qualified electrician if you are
unfamiliar with proper electrical wiring connections. Please review
instructions carefully before proceeding.
WARNING: Risk of fire or electric shock. Do not alter, relocate or remove
wiring uring installation.
This fixture complies with Part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE: Not for use with dimmers. Do not install directly over a heat
source.