Specifications

  • Model: GIE-LF-4FT-50W-L-H
  • Size: 4FT
  • Power: 40/45/50W
  • Input Voltage: AC100-277V
  • Dimmable: Yes (0-10V)
  • Power Factor (PF): >0.9
  • Luminous Efficacy: 130lm/w
  • Color Rendering Index (Ra): 80
  • Color Temperature (CCT):
    3500/4000/5000/6500K

Product Features

  • CCT Tunable: 3500K, 4000K, 5000K, 6500K
  • Watt Tunable: 40W, 45W, 50W

Installation

  1. 1.  **Preparation:** Take out the fixture and accessories package from the box.
  2. Fixing Cable to Canopies:

Release locknut and pass the cable through Canopy A and CanopyB.
Tighten the nut to fix the cable.

FAQ

Q: Can the fixture be dimmed?
A: Yes, the fixture is dimmable with a compatible 0-10V dimmer.

LED Linear Hanging (Suspended) Light

Sunco-Lighting-GIE-LF-4FT-50W-L-H-LED-Linear-Hanging-Light-
\(2\)

Product Features

  • ETL, CETL & DLC listed
    4ft 40W-45W-50W

  • Lumen efficiency: 130lm/w

  • 0-10V dimmable driver

  • Input voltage: 100-277VAC

  • Suspension mounting installation

  • 5-year warranty

Dimension

Sunco-Lighting-GIE-LF-4FT-50W-L-H-LED-Linear-Hanging-Light-
\(3\)

Sunco-Lighting-GIE-LF-4FT-50W-L-H-LED-Linear-Hanging-Light-
\(11\)

Testing Report

LUMINOUS INTENSITY DISTRIBUTION DIAGRAM

Sunco-Lighting-GIE-LF-4FT-50W-L-H-LED-Linear-Hanging-Light-
\(4\)

Simulation Chart

Sunco-Lighting-GIE-LF-4FT-50W-L-H-LED-Linear-Hanging-Light-
\(5\)

Specification

Model| Size| Power| Input

Voltage

| Dimma

ble

| PF| Efficacy| Ra| CCT
---|---|---|---|---|---|---|---|---
GIE-LF-4FT-50W-L-H| 4FT| 40/45/50W| AC100-277V| 0-10V| >0.9| 130lm/w| 80| 3500/4000/5000/6500K

Sunco-Lighting-GIE-LF-4FT-50W-L-H-LED-Linear-Hanging-Light-
\(6\)

Installation

Pendant Mounting, Drywall Ceiling (Offgrid)

  1. Preparation
    Take out the fixture and accessories package from the box.

  2. Fix cable to canopies
    Release locknut, pass the cable through the canopy A and tighten the nut to fix the cable. Repeat to fix cable to canopy B.

  3. Attach power cord to the fixture
    Remove down-light lens with suction cup. Remove the end-cover nearby the outlet hole by removing the 4 screws as shown. Connect power cord to the connector inside housing and fix it to outlet hole with Rubber cable sheath. Then reinstall the end cover.

  4. Install canopy B and hang the fixture right end
    Install the canopy B after positioning the mounting holes with positioning plate. Hang the right end of fixture with cable and adjust to desired height. Make sure that the fixture is securely hung.

  5. Install canopy A
    Pass power cord through the canopy A and connect it to main power wires. Mount the cross-bar onto J-box and fix canopy A to the cross bar to cover the J-box.

  6. Hang the fixture left end
    Make sure that the fixture is securely hung. The installation is completed.

CAUTION

Please isolate two dimming wires (pink and purple) by P2 terminal individually if no need dimming; MUST connect wires with corresponding colors.

Notes

  1. The installation and maintenance must be completed by electricians or professionals.
  2. Please cut off the power before installation and maintenance.
  3. The fixture is not allowed to be covered thermally insulating material.
  4. Please keep away from the corrosive substance and keep the fixture clean and dry.
  5. Working temperature: -4°F to 104°F, storage temperature: -22°F to 140°F.