HYCO W28 Series 2D Ring Scanner User Manual

June 5, 2024
hyco

HYCO W28 Series 2D Ring Scanner

Disclaimer

Disclaimer @2018 Shanghai Hyco Genyong Technology Co., Ltd. All rights reserved. Please read through the manual carefully before using the product and operate it according to the manual. It is advised that you should keep this manual for future reference. Do not disassemble the device or remove the seal label from the device. Otherwise, Shanghai Hyco Genyong Technology Co., Ltd. does not assume responsibility for the warranty or replacement. All pictures in this manual are for reference only and actual product may differ. Regarding to the product modification and update, Shanghai Hyco Genyong Technology Co., Ltd. reserves the right to make changes to any software or product to improve reliability, function, or design at any time without notice. Besides, the information contained herein is subject to change without prior notice.
The products depicted in this manual may include software copyrighted by Shanghai Hyco Genyong Technology Co., Ltd. or a third party. The user, corporation or individual, shall not duplicate, in whole or in part, distribute, modify, decompile, disassemble, decode, reverse engineer, rent, transfer or sublicense such software without prior written consent from the copyright holders. This manual is copyrighted. No part of this publication may be reproduced or used in any form without written permission from Hyco. Please visit www.hycoiot.com or check the latest version of the specification sheet for the latest product information.

Design

Ring Scanner

  •  Wearing: wear on index finger on left or right hand
  •  Scanning: touch either side of ring body with thumb finger to trigger the scanning

Ring scanner charging cradle(Bluetooth Receiver)

Charging

Charging Ring Scanner

Connect the Ring scanner charging cradle to power, click the ring scanner into the bottom of cradle with the scan window upward. Please note the power contacts of the ring and cradle must be touched. The red light indicates it is in charging, when the green light turns on, it’s finished charging.

Warning:
don’t look straightly into the scan window when scanning in case of harm to eyes.

Take the Ring Scanner out of the Ring scanner charging

cradle
Hold the middle of the ring scanner gently and pull out upward from the cradle.

Ring Scanner Modes

SPP Mode (default factory settings) Charging cradle connection and program docking mode

To connect with PC via USB cradle, scan COMMON code, and scanning barcode is available. (Random terminal system is acceptable with the cradle) In this protocol transmission mode, if you need different system programs docking, please get the relevant development SDK at the official website or contact the relevant agent technical support.

HID Mode
Use the terminal device directly. Output barcodes in HID keyboard mode searched by default Bluetooth. According to the actual system, scan the barcode corresponding to the system and connect.

If the device is connected to IOS smartphone/tablet, scan the IOS code to read the barcodes.

If the device is connected to an ANDROID smart phone/tablet, scan the ANDROID code to read the barcodes.

If the device is connected to WINDOWS smart phone/tablet, scan the WINDOWS code to read the barcodes.

Bluetooth connection

Connect with PC:
Connect the cradle with the PC with USB, and the green light means normal connection. After 15 seconds, scan the Bluetooth connection barcode with the ring scanner, and a blue light indicates successful connection.

Connect with an Android smart phone/tablet:
First, find the Bluetooth connection barcode on the side of the cradle, scan it with the ring scanner, and change the Bluetooth name to the serial number so that the device can be found; Then open ‘Bluetooth Search’ at the setting menu, find the Bluetooth serial number in the list and connect. Green light indicates successful connection.

Components

Specifications

Model W28
Scanner HYCO CMOS-Sensor Scanner
Resolution 1280×800 pixcels
Code Reading Barcodes/2D codes
Scanning Distance Long, general or macro type
Weight 20g (without strap)
Dimensions (WDH) 38.6mm29.0mm22.1mm
Ring Straps 10 pcs in different sizes
Bluetooth BT4.2, BLE
LED Indicator RGB LED (programmable)
Vibration Indicator Supported
Battery 200mAh@3.7V
Charging Cradle With USB dongle and Bluetooth adapter
Battery Life 8 hours (when fully charged with 15-20cm depth of

field, and scanning once every 5 seconds)

Scanning Trigger| Touch-to-scan
IP Level| IP66
Drop Test| 3 meters
Operating Temperature| -10℃ to 50℃ (14℉ to 122℉)
Humidity| 0%-95%RH (non condensing)

Note:
For Ring Scanner and Ring scanner charging cradle, operating temperature is -10°C to 50°C

Functions

Scanning
Wear on left or right index finger, touch left or right side of ring and aim at the barcode, the ring light turns green, it starts to scan.

Ring Straps
Firstly, straightly pull out ring strap from the slot, then choose another ring strap and push it to the top of slot.

Ring Indicator

  •  The green light indicates successful scanning.
  •  The red light flashing indicates low battery.
  •  The green light keeping on for 1 second indicates successful Bluetooth connection.
  •  The blue light keeping on for 1 second indicates Bluetooth disconnection.
  •  The red, green and blue light flashing indicates restarting.

Bluetooth can’t connect
Normally, if the Bluetooth light doesn’t turn on, user can scan the barcode “Reset Bluetooth Name”, wait for 10 seconds, and reconnect.

Scan the barcode “Restore factory settings”, the ring will disconnect Bluetooth connection with terminal devices, and all the settings will change to factory default.

Charging cradle light indicator
The blue light indicates a successful Bluetooth connection between ring scanner and cradle.

The red light off while the green light on in charging indicates fully charged.

Wake up ring in charging
The ring doesn’t work when in charging, while it could be waked up by touching either side of ring three times.

Laser calibration
If laser length changes longer or shorter, please stop scanning, touch ring for 4 seconds once and repeat several times to get it right. If it’s still abnormal, please scan the barcode “Automatic calibration”.

After scan the barcode “Automatic laser calibration”, the ring turns on purple, put it on the table, wait for 15 seconds until the purple light turns off. The ring laser is calibrated right and functions normally.

Code system on/off

  1.  Basic setting. 4 default code systems on: EAN13, EAN128, CODE128, CODE39; in which CODE128 and CODE39 read at least 2 characters;
  2.  Extended setting. 9 default code systems on: EAN8, EAN13, EAN128, UPCA, UPCE, CODE128, CODE39,CODE93, ITF25; in which CODE128 reads at least 1 character; ITF25 only reads 14 characters as default.

If a code system and code length are not included please contact technical support and local distributor.

Touch switches on both sides
The touch switch on the left and right sides of the ring scanner are both on by default. If you need to turn off one side, please use the following barcodes to turn it on/off.

Service

Warranty: one year for ring scanner, half year for battery and accessories.

Notice

  •  The ring window must be kept clean. Improper usage will breach the limited warranty clause.
  •  Avoid rough objects scratching the window.
  •  Remove stains from window by soft cloth.
  •  Do not spray any liquid onto the window.
  •  Use cleaning water to clean.

Function barcodes setup

Common Setting
[Equipment information]
Scan below barcode to get device information when successful connect to terminals

[Restore factory setting]
Scan below barcode to restore factory setting, The device will disconnect from the cradle, and the identifiable code system and Bluetooth name will be restored to the default factory settings.

[Restart]
Scan below barcode to restart device

[Turn on/off vibration] Scan below barcode to turn on/off vibration

Add Enter/Tab
After scan “Add Enter” barcode, it can automatically move to next line in the text field after each scanning. If user wants to close the function, scan “Delete Enter” barcode.

After scan “Add the tab” barcode, it can automatically move to next line in excel after each scanning close the function, the tab” barcode.

Trigger mode setting
[Automatic interval scanning]
After scan “Automatic interval scanning” bar code, ring could automatically scan every 0.5 ~ 3 seconds without touching (2 seconds by default)

[Triggered continuous scanning]
Scan the barcode “Triggered continuous scanning”, ring could keep scanning when user keeps touching the ring.

[Manual Trigger Mode]
“Manual Trigger Mode” is set by default, user needs to touch ring once to scan once. User can switch to this model by scan below barcode.
Automatic Scan setting
Scanning [interval scan time-increase] bar code, you can increase the light- off time after successful scanning [each time increase by 0.5 seconds, the longest does not exceed 2.5 seconds] Scanning [interval scan time-decrease] bar code, can reduce the light-off time after scanning is successful [decrease by 0.5 seconds each time, the shortest is not less than 0.5 seconds] Note:
This time is available when the scan mode is automatic gap scan mode.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals