AURATON Cetus Wired Temperature Controller User Manual

June 5, 2024
AURATON

AURATON logo Cetus

User’s Manual

The extended manual can be found at:

https://manuals.auraton.pl

Producent

Choosing the right location for the AURATON Cetus AURATON Cetus Wired
Temperature Controller - fig1

Daily, wired thermostat
AURATON Cetus is a daily, wired thermostat designed to work with a gas or electric heating device.AURATON Cetus Wired Temperature Controller -
fig2

Thermostat

  1. LCD display
  2. setting knob with integrated „OK” button
  3. ON/OFF button
  4. Manual mode button
  5. Temporary temperature reduction mode button
  6.  temperature setting button

AURATON Cetus Wired Temperature Controller - fig3

 Display

  1. Temperature
  2. Low battery (    ****)
  3. Temporary temperature reduction mode duration indicator
  4. Temperature unit (R)
  5. Manual control indicator (  )
  6. Temporary temperature reduction mode programming indicator(  )
  7. AURATON Cetus power-on symbol ( )
  8. Temporary temperature reduction mode indicator (   )
  9. Number of days in the holiday mode ( 1-7 )

Installing batteries in AURATON Cetus

AURATON Cetus Wired Temperature Controller - fig4

Connecting cables to AURATON Cetus
A – cover;
B – screw;
C – wire terminals

Setting the temperature AURATON Cetus

Simplified diagram of connecting the thermostat with the heating device

  1. Heating device e.g. a gas furnace;
  2. Electric heating device

Technical specifications

Power supply: 2 x AAA (2 x 1.5 V), alkaline
Working temperature range: 0 – 45°C
Signaling the working status: LCD
A number of temps. levels: 1
Anti-freeze temperature: 2°C
Temperature measurement range: 0 – 35°C
Temperature measurement range: 5 – 30°C
Temperature setting accuracy 0,2°C
Hysteresis: ±0.2°C / ±0.4°C / PWM
Relay load capacity: Max. 250 V AC, max. 16 A
Working cycles: Daily
Level of security: IP20
Dimensions [mm]: 90 x 90 x 36

Disposing of the devices
The devices are marked with the crossed waste bin symbol. According to European Directive no. 2012/19/UE and the Act concerning used up electric and electronic equipment, such a marking indicates that this equipment may not be placed with other household generated waste.
The user is responsible for delivering the devices to a reception point for used-up electric and electronic equipment.

Documents / Resources

| AURATON Cetus Wired Temperature Controller [pdf] User Manual
Cetus, Wired Temperature Controller, Cetus Wired Temperature Controller
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals