storyblok MQ03-8I GPRS Communicator with Serial Port Interface Installation Guide

June 5, 2024
Storyblok

storyblok-logo

storyblok MQ03-8I GPRS Communicator with Serial Port Interface

storyblok MQ03-8I GPRS Communicator with Serial Port Interface-
fig1

Connecting the communicator to the alarm panel

  • (+) 12VDC Power Supply
  • (-) Ground
  • Rx, Tx For optional integration with supported panels via serial port
  • IN1 Status
  • IN2 Alarm
  • IN3 Tamper
  • IN4 Panic
  • IN5 Alarm
  • IN6 Alarm
  • IN7 Alarm
  • IN8 Alarm

WARNING: The wiring should be done only when the panel and the communicator are disconnected from the powerline!

  • Connect the antenna to the device and place the antenna outside of the alarm panel’s box
  • Connect + and – of the communicator to 12V-15V DC power supply

LED Indicator

  • Slow flashing – trying to establish a connection
  • Constantly On – connection established at good signal level
  • Constantly On, blinking every 10 secs – connection established at low signal level
  • Fast flashing – transferring data

Selecting the model of the alarm panel (when using the serial port interface)

  • Enter in the RControl Administrative website. Open the “Device Dashboard” and navigate to“Advanced Settings”
  • Check the “Enable Online Settings” checkbox and press “Get Current Settings” (the device should be powered and connected)
  • From the “COM 1”-> “Events” drop box menu select the alarm panel’s model
  • Click “Save” to confirm the changes

Configuring a backup of the alarm events (when using the serial port interface)

  • Configure a PGM of the panel to be activated (switch to ground) in case of any alarm event(refer to the panel’s installer manual)
  • Wire that PGM to IN2 of the communicator (programmable input, preconfigured as Alarm)

Events reporting to end users via a smartphone

  • Download the RControl mobile application on your Android or iOS from the links below
  • Login with the end user credentials provided within this installation manual
  • It is recommended to change the User name and Password after the first login

With the RControl mobile application the end user can:

  • Monitor the current status of the alarm panel
  • Get real-time notifications
  • View events log up to one year back in time
  • Remotely Arm/Disarm the alarm system (optional)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Storyblok User Manuals

Related Manuals