storyblok MQ03-8I GPRS Communicator with Serial Port Interface Installation Guide
- June 5, 2024
- Storyblok
Table of Contents
storyblok MQ03-8I GPRS Communicator with Serial Port Interface
Connecting the communicator to the alarm panel
- (+) 12VDC Power Supply
- (-) Ground
- Rx, Tx For optional integration with supported panels via serial port
- IN1 Status
- IN2 Alarm
- IN3 Tamper
- IN4 Panic
- IN5 Alarm
- IN6 Alarm
- IN7 Alarm
- IN8 Alarm
WARNING: The wiring should be done only when the panel and the communicator are disconnected from the powerline!
- Connect the antenna to the device and place the antenna outside of the alarm panel’s box
- Connect + and – of the communicator to 12V-15V DC power supply
LED Indicator
- Slow flashing – trying to establish a connection
- Constantly On – connection established at good signal level
- Constantly On, blinking every 10 secs – connection established at low signal level
- Fast flashing – transferring data
Selecting the model of the alarm panel (when using the serial port interface)
- Enter in the RControl Administrative website. Open the “Device Dashboard” and navigate to“Advanced Settings”
- Check the “Enable Online Settings” checkbox and press “Get Current Settings” (the device should be powered and connected)
- From the “COM 1”-> “Events” drop box menu select the alarm panel’s model
- Click “Save” to confirm the changes
Configuring a backup of the alarm events (when using the serial port interface)
- Configure a PGM of the panel to be activated (switch to ground) in case of any alarm event(refer to the panel’s installer manual)
- Wire that PGM to IN2 of the communicator (programmable input, preconfigured as Alarm)
Events reporting to end users via a smartphone
- Download the RControl mobile application on your Android or iOS from the links below
- Login with the end user credentials provided within this installation manual
- It is recommended to change the User name and Password after the first login
With the RControl mobile application the end user can:
- Monitor the current status of the alarm panel
- Get real-time notifications
- View events log up to one year back in time
- Remotely Arm/Disarm the alarm system (optional)
Read User Manual Online (PDF format)