Installation Instructions

IMPORTANT

  • Inspect your new toilet suite before installation to ensure no damage has occurred during transit. If damage has occurred,or visible defects exist, do not proceed with the installation and advise
    the retailer immediately. No claims will be accepted after installation is commenced.

  • It is recommended that the toilet seat and cover be installed after all trades has completed.

  • All measurements for roughing-in should be taken from the finished wall/floor.

  • All installation works must be done by qualified trade persons.

  • Elite bathroom ware will not be liable for the cost of installation or removal of the toilet and the warranty will be voided if damage occurs during or after installation.

DESCRIPTION

  • This suite is a fully concealed, back-to-wall suite that has a variable set out of the pan.
  • This suite can be connected in a P-trap configuration (fittings not supplied). It can also be connected in an S-trap configuration with an adjustable S-trap convertor fitting (supplied) with 90-185 settings. This suite comes with a rear back entry water inlet valve. The position is shown in the diagram below.
  • The cistern is bolted to the pan from inside of the cistern tank and can be removed, if necessary, for servicing without removing the pan.
  • The suite has a soft close seat that is attached via top-fixed bolts. The seat is removable for cleaning and replaceable without removing the pan.CODE BTW Pure Overheight Toilet Suite-FIG1

INSTALLATION

  • Check site roughing-in, cistern tap position, and assembly dimensions before starting installation.
  • The toilet pan must be installed on a level surface. If the wall or floor is out of level, a gap will show at the top or bottom against the wall.
  • Place the pan in position ensuring it is aligned with the centerline of the sewer connection.
  • Mark on the floor – the location of pan-fixing bolt holes.
  • Remove the pan and locate the position of the floor brackets. Fix floor fixing brackets to the floor (Diagram 1).
  • For P-trap installation, A pan connector (not supplied) and extension (not supplied) will be required. Place the pan into position ensuring it seals firmly to the pan connector.
  • For S-trap installation Adjust the bracing prop and pan convertor to the correct length which to suit the set-out. Install the converter and screw the bracing prop to the back wall. Align and push the toilet pan back to the wall. Check the outlet connection fits with the pan and is fully back against the wall (Diagram 2).
  • Insert floor bracket screws through the fixing holes and hold the pan in position.
  • Attach decorative caps.
  • Peel off the paper from the self-adhesive cistern to pan seal and stick the seal in the correct position on the cistern.
  • Put the threaded inserts into holes of the toilet pan, and fixed by hex nuts (supplied) (Diagram 3). Secure the cistern to the toilet pan by screwing the cistern fixing bolts and washers to the threaded insert. Screw down firmly and evenly to compress the rubber sealing ring.
  • Always flush the water supply pipe before connecting the cistern inlet valve to the cistern tap.
  • Attach the inlet valve flex hose to the water supply/cistern tap. See Diagram 4 for the suggested way of connection.CODE BTW Pure Overheight Toilet Suite-FIG5
  • Fill the cistern with water and check the water level, adjust the inlet valve float, if necessary.
  • Attach the cistern lid and buttons, test flush several times while checking for leaks, if any.
  • Waterproof sealant finishing may be used around the base of the toilet pan.
  • Fit seat and cover.