BVF Heating Solutions BVF 24-X 16A RF Receiver User Manual

June 5, 2024
BVF Heating Solutions

BVF Heating Solutions BVF 24-X 16A RF Receiver

TECHNICAL DATA

Receiver Current Load: 230V, 50/60Hz
Capacity:  3600W/16A
External sensor: NTC 10kΩ @ 25°C
Frequency:  868MHz
Dimensions:  86mm x 86mm x 26mm
Relay inst. dimensions:  Ø 65 mm diameter, min. 55mm depth
Color:    White
IP protect rating: IP 20
Certification:  CE

PAIRING WITH 24-F

Enter the parameter setting page (see the details in the 24-F manual), then select the appropriate setting in sensor select menu nr. 4 as follows:

  •  Use Setting 1 for floor heating (double sensor setting)
  •  Choose Setting 3 for comfort floor heating (floor sensor only)
  •  Setting 0 is only applied to infrapanel heating with a single-room sensor function

BVF Heating -Solutions- BVF -24-X -16A- RF -Receiver-
fig-1

Pairing process

  1.  Long press the code pairing button on the receiver until the LED flashes.
  2.  Turn off the sender by pressing on/off button, and long press until the RF code shows on the screen (XXXX), then please rotate the button to left or right, the icon starts flashing.
  3.  Wait for a while till the icon stops flashing. Code pairing finished.

BVF Heating -Solutions- BVF -24-X -16A- RF -Receiver-
fig-2

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals