BVF Heating Solutions BVF 24-X 16A RF Receiver User Manual
- June 5, 2024
- BVF Heating Solutions
Table of Contents
BVF Heating Solutions BVF 24-X 16A RF Receiver
TECHNICAL DATA
Receiver Current Load: 230V, 50/60Hz
Capacity: 3600W/16A
External sensor: NTC 10kΩ @ 25°C
Frequency: 868MHz
Dimensions: 86mm x 86mm x 26mm
Relay inst. dimensions: Ø 65 mm diameter, min. 55mm depth
Color: White
IP protect rating: IP 20
Certification: CE
PAIRING WITH 24-F
Enter the parameter setting page (see the details in the 24-F manual), then select the appropriate setting in sensor select menu nr. 4 as follows:
- Use Setting 1 for floor heating (double sensor setting)
- Choose Setting 3 for comfort floor heating (floor sensor only)
- Setting 0 is only applied to infrapanel heating with a single-room sensor function
Pairing process
- Long press the code pairing button on the receiver until the LED flashes.
- Turn off the sender by pressing on/off button, and long press until the RF code shows on the screen (XXXX), then please rotate the button to left or right, the icon starts flashing.
- Wait for a while till the icon stops flashing. Code pairing finished.